background image

INNOVATIVE HEARTH PRODUCTS  •  POWER VENT DV GAS FIREPLACES  (DRT63__TYN / DRC63__TYN)  •  CARE AND OPERATION INSTRUCTIONS

25

Power Vent Motor 

Is Working?

Does the Pilot 

Spark?

Pilot Burner 

Lights?

Does Spark 

Stop When Pilot 

Lights?

Does Main Burner 

Light?

System Runs 

Continuously 

Until Switched 

OFF?

START

ON/OFF Switch or Remote 

ON? Is There 120 V Power 

to the Fireplace? Are All 

Wiring Connections Tight? 

(Turn OFF Power Before 

Checking)

Yes

No

Yes

Is There 120V Power 

to the Motor?

Replace Blower

Yes

Yes

Is the Pressure 

Switch Closed?

No

No

No

Is There Blockage in the Vent? 

Is There Water/Dirt in the Hose from 

the Blower to the Pressure Switch? 

Are the Hose Connections Loose? 

Is the Hose Cracked?

Replace Pressure 

Switch

Replace Control 

Module

Yes

Yes

Is the Lead to the 

Spark Electrode 

Attached or Arcing 

to Ground? Is the 

Electrode Cracked?

No

Replace Ignition Module

Is Pilot Gas Line 

Blocked? Is Pilot 

Orifice Blocked?

No

Yes

Yes

Replace Pilot

Does Pilot Flame 

Cover the Flame 

Rod?

No

Yes

No

Is the Flame Rod Corroded? 

Is the Pilot Hood Corroded?

Is Flame Rod Insulator Cracked?

Is Wire to Flame Rod Damaged?

Replace Ignition Module

Check Pilot for Obstruction. 

Check Gas Pressure. 

Adjust Pilot Flame.

No

Yes

No

Are Wires to Valve 

Loose Or Corroded?

No

Is There Manifold Pressure?

Replace Gas Valve

No

Yes

Check Position of 

Pilot. Is Orifice 

Blocked?

No

Replace Ignition Module

No

Does the Pilot Flame Cover the Flame Rod?

Is the Sensor Wire in Good Condition?

Is There Continuity to Ground from the Pilot Burner?

No

Replace Control Module

Does Pressure Switch Open During Operation?

Yes

No

Replace Ignition Module

Yes

Is Vent Partially Blocked?

Is There Water/Dirt in Hose to Pressure Switch?

Are Hose Connections Loose?

Is the Hose Cracked?

Replace Pressure Switch

No

Replace Control Module

No

Does System Run 

Continue?

Replace Ignition 

Module

No

Yes

WARNING: Never Jump The Pressure 

Switch Out Of This System. Property 

Damage, Injury Or Death May Result. 

Unit Will Not Start If Pressure Switch 

Is Jumped.

Is Presure 

Switch Open 

When Unit Is 

Turned OFF?

Yes

No

Replace Pressure 

Switch (Ensure 

Power Vent Motor 

Is NOT Running)

TROUBLESHOOTING GUIDE 
Power Vent System

NOTE: Service must be performed by a qualified installer, service agency, or your gas supplier.

BEFORE TROUBLESHOOTING THE UNIT:
1. Confirm there is power to the unit (fireplace).
2. Confirm there is gas to the unit (fireplace).
3. The igniter module in the fireplace is equipped with a device that can put the unit into a lockout state. Follow the steps in the chart below to 

reset the control: Turn the ON/REMOTE/OFF switch to the OFF position, or turn the remote to the OFF position. 

4. If this is the first time that the unit has been fired, check the wiring of the unit against the wiring diagram before commencing 

troubleshooting.

Summary of Contents for 40 Signature series

Page 1: ...REN TO TOUCH GLASS UNE SURFACE VITRÉE CHAUDE PEUT CAUSER DES BRÛLURES LAISSER REFROIDIR LA SURFACE VITRÉE AVANT D Y TOUCHER NE PERMETTEZ JAMAIS À UN ENFANT DE TOUCHER LA SURFACE VITRÉE EL VIDRIO CALIENTE CAUSARÁ QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any...

Page 2: ...tion 7 BTU Input 7 Gas Pressure Requirements 7 Orifice Sizes 7 Burn In Period 7 Operation and Care of Your Appliance 8 Gas Controls Control Compartment Access 8 Appliance Operation 8 Purge Cycle 8 Remote Control System 9 Lighting the Appliance 11 Power Vent Operation 11 Maintenance 12 Front Glass Enclosure Panel Removal Installation 13 Log Volcanic Stone and Glowing Ember Placement 14 Burner Adjus...

Page 3: ...oir Page 5 Lisez la section Informations importantes relatives à la sécurité Page 4 Toutes les parties de votre foyer Innovative Hearth Products deviennent EXTRÊMEMENTCHAUDES Instale una malla o barrera física para evitar el contacto directo con el vidrio y prevenir las quemaduras y lesiones graves Ver los detalles a la izquierda para ordenar un SAFETY GUARD GRATIS para su chimenea Siga las instru...

Page 4: ...dultes peuvent subir des brûlures s ils viennent en contact avec la surface chaude Il est recommandé d installer une barrière physique si des personnes à risques habitent la maison Pour empêcher l accès à un foyer ou à un poêle installez une barrière de sécurité cette mesure empêchera les tout petits les jeunes enfants et toute autre personne à risque d avoir accès à la pièce et aux surfaces chaud...

Page 5: ... les traces de graisse ou d huile Collez l étiquette sur la surface de la plaque du récepteur mural qui contrôle le foyer Figure A Choisissez la langue qui est principalement parlée dans la résidence du propriétaire 2 Repérezlatélécommandeetnettoyez lasoigneuse ment pour éliminer la poussière et les traces de graisse ou d huile Collez l étiquette sur le boîtier de la télécommande Figure B Choisiss...

Page 6: ... fireplaces are designed as decorative appliances and are not intended for use as area heaters They must not be equipped with wall thermostats or remote controls with thermostat functions CAUTION Hotwhileinoperation Donot touch Severe Burns may result Keep children clothing furniture gasoline and other liquids having flammable vapors away ATTENTION L appareil est chaud lorsqu il fonctionne Ne pas ...

Page 7: ...CURING PROCESS CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR Flame breadth height and width will diminish 4 for every 1 000 feet of altitude Input BTU HR Natural Gas Model No Input BTU Hr 40 in 26 500 42 000 45 in 35 000 48 000 Table 1 BTU Input The BTU Input for these appliances is shown in Table 1 Gas Pressure Requirements Tables 2 and 3 show the appliances gas pressure requirements I...

Page 8: ... others may be susceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to a fireplace or stove install an adjustable safety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces AVERTISSEMENT Lesjeunesenfantsdevraientêtresurveillésétroitementlorsqu ilssetrou ve...

Page 9: ...to the gas valve coil and the appliance main burner turns on A single beep from the receiverwillconfirmreceptionofthecommand Turn OFF the Appliance Press the ON OFF Key on the transmitter The transmitterLCDdisplaywillonlyshowtheroom temperature and icon At the same time the receiver disconnects the gas valve coil and the appliance burner turns off A single beep from thereceiverconfirmsreceptionoft...

Page 10: ...transmitter are low or depleted the appliance can be turned on manually by sliding the ON REMOTE OFF slider switch to the ON position This will bypass the remote control feature of the system and the appliance main burner will come on if the gas valve is in the ON position Transmission Set Point Temp Level State Flame On Child Safety Lock Out Low Battery Alarm Room Temperature Maximum Level Indica...

Page 11: ...ing and pilot will light 4 Burner should light after a few seconds To turn ON the appliance with the remote transmitter 1 ManuallyslidetheON REMOTE OFFswitch totheREMOTEposition thenpresstheON OFF key on the transmitter 2 Blower should start immediately 3 Igniter starts sparking and pilot will light 4 Burner should light after a few seconds To Turn OFF 1 ManuallyslidetheON REMOTE OFFswitch to the ...

Page 12: ...50 mix of white vinegar water Gas fireplace stove glass cleaner Inspect Glass Gasket Visuallyinspectthegasketonthebacksideofthe glassenclosurepanels Thegasketsurfacemust be clean free of irregularities and seated firmly Clean Control Compartment Keepcontrolcompartmentcleanbyvacuuming or brushing at least twice a year More frequent cleaning may be required due to excessive lint from carpeting beddi...

Page 13: ...osure Panel Top Flange Glass Door Frame Assembly Glass Door Latch 2 Latch Screws Firebox Floor Glass Door Assembly WARNING When reinstalling the glass door the door latch screws must be securely tightened to prevent the glass door from falling out which could potentially cause damage and possible injury Donotattempttosubstitutethe materials used on this door or replace cracked or broken glass Hand...

Page 14: ...andpreventsooting Whenpositionedproperly as shown twigs will be positioned between flame peaks and will not impinge any flames WARNING DO NOT attempt to install the logs until the appliance installation has been completed the gas line connected and tested for leaks and the initial burner operation has been checked out The size and position of the log set was engi neered to give the appliance a saf...

Page 15: ...Grate And Push It Towards The Rear 3 2 4 1 6 5 7 Log Number Description 1 Log Center 2 Log Rear 3 Log Center Left 4 Log Center Right 5 Log Rear Top 6 Log Front Left 7 Log Front Center Table 6 Log Set Align Hole At Bottom Of Log 5 Over The Pin On Log 2 6 5 7 2 Figure 16 Placing Logs 5 6 and 7 Engage Log 6 With The Grate Pin And Align Groove At The Bottom Of The Log Over The Grate Engage Log 7 With ...

Page 16: ... termination Sooting is caused by incomplete combustionintheflamesandlackofcombustion air entering the air shutter opening To achieve a warm yellow orange flame with an orange body that does not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines If there is smoke or soot present first check the log set positioning to ensure that the flames are no...

Page 17: ...o adjust the flame move the adjustment air shutter located on the lower venturi back or forward to increase or reduce the air shutter opening respectively Position the air shut ter to the factory setting as shown in Table 8 Allow the burner to operate for at least 15 minutes Observe the flame continuously If it appearsweakorsootyaspreviouslydescribed adjusttheairshutteruntiltheflameappearance is a...

Page 18: ...is system please contact your dealer or distributor Innovative Hearth Products 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Visit us at www superiorfireplaces US com PRODUCT REFERENCE INFORMATION We recommend that you record the important reference information about your fireplace in the space provided below Please call Innovative Hearth Products for the phonenumberofyournearestInnovativeHearth...

Page 19: ...mic and porcelain panels of the side and rear walls The ceramicpanelshavebrick likefeaturesinrelief Andiron Door Kit The andiron kit attaches to the grate assembly without the use of hardware Firebox Accessories Cat No Model Description 88L53 FGE Bag of Glowing Embers 80L42 FDVS Bag of Volcanic Stone H8312 PGE Bag of Platinum Embers Ceramic and Porcelain Firebox Liner Kits Model Cat No Model Descr...

Page 20: ...Screen Panel Kits These screen panel kits create a barrier to prevent direct contact with the hot glass The screen panel affixes directly to the front glass enclosure panel Log Set Cat No Description F1719 Aged Oak Logs Barrier Screen Kits Cat No Model Description H4805 BSK40 40 Barrier Screen H4806 BSK45 45 Barrier Screen Dual Arch Screen Kits Cat No Model Description H5051 DASK LSM40IN 2 40 Scre...

Page 21: ...ese instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand B BEFORE OPERATING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the fl...

Page 22: ...tape suivante 8 Mettez l appareil sous tension 9 Placez l interrupteur du récepteur en position REMOTE 10 Appuyez sur le bouton ON OFF pour sélectionner ON 11 Si applicable Ajustez le thermostat sur la télécommande à l ajustement désiré 12 Si l appareil ne se met pas en marche suivez les instructions intitulées Comment couper l admission de gaz de l appareil et appelez un technicien qualifié ou le...

Page 23: ...g exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the appropriate appliance checkout procedure detailed in this manual Replace Glowing Embers Homeowner Qualified Service Technician Remove old ember materials rockwool and vacuum the ember placement area Place new embers per instructions o...

Page 24: ...n immediately goes out Gas is not reaching the fireplace Check the gas supply and gas shutoff valves call a service technician if required Loose wires to the valve or ignition module Check the gas supply and gas shutoff valves call a service technician if required Pilot flame is not engulfing the sensor Call a service technician Obstructed vent system Call a service technician Log and glass soot F...

Page 25: ...e No Yes Check Position of Pilot Is Orifice Blocked No Replace Ignition Module No Does the Pilot Flame Cover the Flame Rod Is the Sensor Wire in Good Condition Is There Continuity to Ground from the Pilot Burner No Replace Control Module Does Pressure Switch Open During Operation Yes No Replace Ignition Module Yes Is Vent Partially Blocked Is There Water Dirt in Hose to Pressure Switch Are Hose Co...

Page 26: ...9 1 10 Screen H1427 2 H1169 2 11 Gasket Access Plate H1452 1 H1452 1 12 Gas Line Tubing H2283 1 H2284 1 13 Connector Male H2285 1 H2285 1 14 Orifice Natural Gas H7924 1 H8141 1 15 Bag of Glowing Embers 88L53 1 88L53 1 16 Grate Assembly Traditional only H4907 1 H4907 1 17 Gas Line Flexible Connection 93L32 1 93L32 1 18 Modesty Panel Right Side H3371 1 H3372 1 19 Modesty Panel Left Side H3373 1 H337...

Page 27: ...RODUCTS POWER VENT DV GAS FIREPLACES DRT63__TYN DRC63__TYN CARE AND OPERATION INSTRUCTIONS 27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 23 15 21 22 7 17 13 12 6 8 11 10 9 5 1 4 16 3 20 19 18 25 24 14 Replacement Parts ...

Page 28: ...8 H7375 Wrapper Top 1 19 H7373 Wrapper 1 20 H7374 Wrapper Bottom 1 21 H7377 Junction Box 1 22 H7379 Diverter Front 1 23 H7380 Diverter Back 1 24 H7376 Wrapper Cover 1 25 H7381 Wire Mesh 1 24 18 19 17 16 15 14 8 25 22 23 21 1 4 20 7 5 2 6 3 Printed in U S A 2013 Innovative Hearth Products LLC P N 506010 12 Rev NC 12 2013 Innovative Hearth Products reserves the right to make changes at any time with...