superior fires F500368 Installation & User'S Instructions Download Page 7

Ensure all/any protective film is removed as
the facia may be damaged if the fire is lit with
the facia in position whilst still covered in
film.

Bellevue Models : 

The facia panel is sup-

plied attached to the fire. To remove the
facia panel, first, remove the retaining
thumbscrews (one on each side of the appli-
ance). Simply lift the frame upwards.
Refitting is the reverse of removal. Ensure
the cut-outs in the bottom of the frame sup-
port brackets engage the lower thumb-
screws on each side of the appliance.  See
figure 9.

Grand Models : 

Remove the facia panel

from any protective packaging. The facia
panel is supported by four M6 screws which
protrude from the front of the outer casing. 
Ensure each screw is unscrewed approxi-
mately one turn from the fully screwed in
position in order to create a 2mm gap (shown in figure 10).  Simply hang the facia panel onto the outer casing (figure 10) ensur-
ing that the corresponding keyhole shaped holes engage the screwheads fully

.

All instructions must be handed to the user for safekeeping. Show the customer how to light and control the fire. 
After commissioning the appliance, the customer should be instructed on the safe use of the appliance and the need for regular
servicing.  Frequency of service depends on usage, but MUST be carried out at least once annually.
Advise that cleaning of the fire may be achieved when the fire is cold using a damp cloth and mild detergent on most surfaces.
Advise that on first light up of a new appliance, initial curing of high temperature paint and burning off of lubricants may occur for
the first few hours of operation. During this period some smoke may be emitted from the outlet grille, this should be no cause
for concern.  Accordingly, the room should be well ventilated with all windows and doors open during this period. During this
period the appliance may cause smoke alarms to sound. If this happens, reset the alarms, but do not remove the batteries.
Recommend that a guard be used for the protection of the young, pets, the elderly and the infirm.
Advise the customer that the ventilation openings should not be blocked or obstructed in any way.

Isolate the fire from the gas supply.  Ensure that the fire is fully cold before attempting service.  
A suggested procedure for servicing is detailed below.

8.3 DECORATIVE FRAME ASSEMBLY

9.0 BRIEFING THE CUSTOMER

10.0 SERVICING

Figure 9

1. Lay out the dustsheet and tools.
2. Remove the decorative frame/glass facia assembly( see section 8.3).
3. Remove the glass door assembly (4 screws) and clean carefully.
4. Inspect the burner and the catalyst and clean if necessary with a soft brush.
5. Disconnect the gas supply.
6. Undo the four screws retaining the burner support brackets to the base and rear of the firebox.  Remove the control knob
and spindle assembly from the valve by removal of the spindle retaining clip.
7. Remove the burner unit, strip off the burner pipes and clean thoroughly.
8. Clean the in-line restrictor, pilot assembly and the burner tube. Do not attempt to remove the pilot injector as this can cause damage.
9. Re-assemble components.
10. Turn on the gas supply and leak test. Check pilot and burner for good ignition.
11. Refit the glass door assembly, ensuring correct orientation and a good seal.
12. Refit the decorative facia assembly as detailed in section 8.3. 
13. Check the purpose provided ventilation is un-obstructed.
14. Light the fire and test operating pressures.
15. Check safe operation of the appliance by performing a combustion test as detailed in section 10.3.  

For specific servicing instructions, see relevant sections.

7

©

2011 Focal Point Fires plc.

GB IE

1.Remove
retaining
Thumbscrews

2.Lift frame
away from
supporting
pins

Figure 10

2mm

Summary of Contents for F500368

Page 1: ...the text images and layout of this booklet is owned by Focal Point Fires plc You are not per mitted to copy or adapt any of the content without the prior written permission of Focal Point Fires plc 1...

Page 2: ...used in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room On first lig...

Page 3: ...cept bathrooms or bedrooms The appliance is designed to be versa tile and as such will operate correctly when exposed to normal gentle draughts experienced within the home It is not recom mended howev...

Page 4: ...may cause cracking along the joint line If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to carry the weight of the...

Page 5: ...on a vertical surface Avoid sloped surfaces Installation onto anything other than a vertical wall may result in fire damage or injury If the appliance is to be mounted on the inner leaf of a conventio...

Page 6: ...it three minutes before repeating the ignition procedure To achieve the HIGH setting push the control knob in slightly and continue turning fully anti clockwise to the high position The main burner sh...

Page 7: ...entilated with all windows and doors open during this period During this period the appliance may cause smoke alarms to sound If this happens reset the alarms but do not remove the batteries Recommend...

Page 8: ...s time the catalysts should be replaced If there are any deposits of dirt or soot on the catalyst they should be cleaned with a soft brush and a vacuum cleaner If removed for cleaning ensure the seals...

Page 9: ...re is a draft Fire is too close the an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughl...

Page 10: ...efects or obstructions that may prevent the satisfactory flow of combustion products The expected life of the catalyst is in excess of 11 000 hours 10 years of normal use After this time the catalyst...

Page 11: ...ary source of heat only and should not be used in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on co...

Page 12: ...Pilot assembly F730086 Gas valve TRAY106 Burner unit L23S models TRAY105 Burner unit L30S models F780079 Catalyst seal kit must also be supplied F940136 Seal kit for Catalyst 7 0 SERVICING 8 0 LIST O...

Reviews: