NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
11
A
B
FRAMING SPECIFICATIONS
Figure 7
Framing Dimensions
Opening
VRT3232WS
VRT3232WH
VRT3236WS
VRT3236WH
VRT3242WS
VRT3242WH
A
38-1/4 (972)
42-1/4 (1073)
48-1/4 (1226)
B
40-1/4 (1022)
40-1/4 (1022)
40-1/4 (1022)
C
19-5/8 (499)
23-5/8 (600)
29-5/8 (753)
D
10-1/4 (260)
12-1/4 (311)
15-1/4 (387)
E
59-3/4 (1518)
63-3/4 (1619)
69-3/4 (1772)
F
29-7/8 (759)
31-7/8 (810)
34-7/8 (886)
G *
20-1/2 (521)
20-1/2 (521)
20-1/2 (521)
H
42-1/4 (1073)
45 (1143)
49-3/8 (1254)
Table 1 - This Table corresponds to Figures 7, 8 and 9
A
C
D
H
F
G
E
Rough Framing Face
(Unfinished Shown)
Back Wall Of Chase/Enclosure
Including Finishing Materials If Any
Back Wall Of Chase/Enclosure
Including Finishing Materials If Any
Rough Framing Face
(Unfinished Shown)
Corner Installation
A
C
G
Parallel Installation
Figure 8
Figure 9
This Figure corresponds to Table 1
This Figure corresponds
to Table 1
This Figure corresponds
to Table 1
Header
WARNING:
• Do not fill spaces around
the firebox with insulation
or other materials.
• Do not notch framing or
alter the spacers on the
appliance.
* Back wall of chase/enclosure including finishing materials, if any.