SPECIFICATIONS

VRE4543EN

•  Rating (Variable): 25/39,000 Btu/Hr
•  Gas Type: Natural Gas
•  Ignition: Electronic
•  Pressure Manifold Setting: 3.5" W.C.
•  Inlet Gas Pressure (in. of water):

  Maximum - 10.5" W.C., 

  Minimum* - 5.5" W.C.
* For purposes of input adjustment

VRE4543EP

•  Rating (Variable): 29/37,000 Btu/Hr
•  Gas Type: Propane/LP Gas
•  Ignition: Electronic
•  Pressure Manifold Setting: 10.5" W.C.
•  Inlet Gas Pressure (in. of water):

  Maximum - 14" W.C.
  Minimum* - 11" W.C.
* For purposes of input adjustment

Note: Use only original replacement parts. 

This will protect your warranty coverage for 

parts replaced under warranty.

Contact authorized dealers of this product. 

If they can’t supply original replacement 

part(s), call INNOVATIVE HEARTH PROD

-

UCTS at 1-800-655-2008.

When calling, have ready:
•  your name
•  your address
•  model and serial numbers of your heater
•  how heater was malfunctioning
•  purchase date
Usually, we will ask you to return the part to 

the factory.

SERVICE HINTS

When Gas Pressure Is Too Low

•  pilot will not stay lit
•  burner will have delayed ignition
•  fireplace will not produce specified heat
•  for propane/LP unit, propane/LP gas supply 

may be low 

You may feel your gas pressure is too low. If 

so, contact your local gas supplier.

TECHNICAL SERVICE

You may have further questions about instal

-

lation, operation, or troubleshooting. If so, 

contact INNOVATIVE HEARTH PRODUCTS 

at 1-800-655-2008. When calling please 

have your model and serial numbers of your 

heater ready.
You can also visit our web site at 

 

www.IHP.US.com

.

ACCESSORIES

NOTICE: All accessories may 

not be available for all fireplace 

models.

Purchase these accessories from your local 

dealer. If they can not supply these accessories 

call INNOVATIVE HEARTH PRODUCTS at 

 

1-800-655-2008 for information. You can also 

write to the address listed on the back page 

of this manual.

SMOOTH GLASS PEBBLES (6 LBS)

GP43SO - Speckled Orange
GP43A - Amber
GP43C - Clear
GP43B - Blue

OUTDOOR SEE-THRU DOOR KIT

LVOST

Summary of Contents for VRE4543E

Page 1: ...mation in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death AVERTISSEMENT Assurez vous de bien suivre les instructions donn es...

Page 2: ...he vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgas...

Page 3: ...njury or death from burns fire explo sion electricalshockandcarbon monoxide poisoning DANGER Carbonmonoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of carbon monoxide poisoni...

Page 4: ...or s phone Follow the gas sup plier s instructions if you cannot reach your gas supplier call the fire department SAFETY Continued 4 This fireplace shall be used only outdoors in a well ventilated spa...

Page 5: ...l gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit Vent free gas products are prohibited for bedroom and bathroom installation in the Comm...

Page 6: ...rances from floor ceiling and adjoining wall Carefully follow the instructions below This will ensure safe installation CLEARANCES Minimum clearances to combustibles for the fireplace are as follows B...

Page 7: ...Depth Ref Mantel from Top of Opening 1 12 A 24 2 9 B 21 3 6 C 18 4 4 D 16 5 2 E 14 A B C D E 1 2 3 4 5 Wall Supplied firebox hood must be used at all times Note All vertical measurements are from top...

Page 8: ...8 INSTALLATION Continued 11 13 16 16 1 2 17 1 2 5 8 29 13 16 8 1 4 1 55 1 16 52 47 44 1 16 29 25 32 7 1 32 16 9 32 2 716 1 816 8 255 13 217 1 816 3 208 Figure 6 V LVFO43E Series Dimensions Gas Line A...

Page 9: ...ry connec tions 3 Slide all wiring connections in electrical housing as shown in Figure 7 4 Secure electrical cover plate with screws previously removed Note Electrical housing and cover plate have sh...

Page 10: ...your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to fireplace If pipe is too small undue loss of volume will occur Installation must include an equipment shutoff valve u...

Page 11: ...of fireplace 2 Attach flexible gas line from gas supply to control valve see Figure 10 3 Check all gas connections for leaks See Checking Gas Connections CHECKING GAS CONNECTIONS WARNING Test all gas...

Page 12: ...propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints from gas meter to equip ment shutoff valve for natural gas or propane L...

Page 13: ...el as a guide screw the rear panel to the fireplace as shown in Figure 14 INSTALLING HOOD 1 Loosen screws at top of face opening and slide hood through screws as shown in Figure 15 2 Tighten screws se...

Page 14: ...ner Figure 20 Installing Access Door Retaining Brackets for See Thru Applications Retaining Bracket Figure 21 Installing Side Face Filler for See Thru Applications Removing Rear Interior Wall 1 Throug...

Page 15: ...ating Control Module 1 Remove Access Plate See Figure 22 2 Remove 2 screws on top of the electronic access cover See Figure 23 3 Remove electronic access cover by gently pulling up and out of the fire...

Page 16: ...located on the right side of the module that reads RE MOTE OFF Figure 26 2 When the remote off switch is in the OFF position the burner will operate from the rocker switch or wall switch connected to...

Page 17: ...r sonal injury or loss of life A This appliance does not have a pilot it is equipped with an ignition device which automatically lights the pilot Do not light pilot by hand B BEFORE LIGHTING smell all...

Page 18: ...the ON position Do not force 8 Replace access cover 9 Turn on all electric power to appliance 10 Turn safety shutoff switch to the ON position 11 Visually locate ignitor Ignitor should begin to spark...

Page 19: ...y by a qualified service person We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater tha...

Page 20: ...ticles enter the fireplace and burn causing brief patches of orange flame Burner flames will be steady not lifting or floating Flame patterns will be different from unit to unit and will vary dependin...

Page 21: ...ge Orange Red Brown Black Solenoid White Brown Brown Green Ignitor Pilot I S AUX AF 5000MOD AF 4000 AF 4000B P Control Module Black Black SWI SWI GND Red HI LO Main Black BATTERY PACK Black Red Black...

Page 22: ...closed 2 Air in gas lines when in stalled 3 Depleted gas supply pro pane LP only 4 Control module not in RE MOTE position 5 Gas control valve pressure setting is not correct 6 Inlet gas pressure is to...

Page 23: ...ignitor assembly is relighting the burner 4 Wire connection loose or wire broken REMEDY 1 Contact local natural or propane LP gas company 2 Clean burner see Cleaning and Maintenance page 18 or replace...

Page 24: ...every one second Gas odor during combustion POSSIBLE CAUSE 1 Appliance burning vapors from paint hair spray glues cleaners chemicals new car pet etc See IMPORTANT statement above 2 Low fuel supply pro...

Page 25: ...www SuperiorFireplaces US com 127035 01A 25 PARTS MODELS VRE4543EN AND VRE4543EP 1 2 4 4 4 4 5 8 6 7 3 9 10 11 19 20 21 12 12 13 14 4 22 15 16 18 17...

Page 26: ...mmet SC 1 2 ID 1 1 16 OD 1 8 116573 01 Flat Washer 7 9 11214 Bulkhead Fitting 1 10 14399 Brass Elbow 2 11 111817 01 Flextube 1 12 125932 01 Burner Gasket 2 13 126050 02 Electronic Access Cover LVFO 1...

Page 27: ...Corner Bracket Stainless 4 10 125766 02 Side Walls 2 11 125761 02 Rear Wall LVFO 1 12 125768 02 Access Door Stainless 1 13 125766 02 Side Face Filler Stainless 2 14 125975 02 Fireplace Hood Stainless...

Page 28: ...lfunctioning purchase date Usually we will ask you to return the part to the factory SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burner will have delayed ignition fireplace will...

Page 29: ...al or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c dam...

Page 30: ...NOTES...

Page 31: ...IS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ________________...

Page 32: ...127035 01 Rev A 01 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P127035 01...