Installation
900079-02J, 05/2019
Innovative Hearth Products
DRL3000 Linear Direct-Vent Gas Fireplaces
57
WARNING
• The glass media was designed to provide a safe, reliable, attractive flame. Any attempt to use media not specified for
this fireplace will result in incomplete combustion, sooting, poor flame quality, and will void the warranty.
• Glass media gets very HOT during fireplace use and will remain hot up to ONE HOUR after gas supply is turned
off. HANDLE MEDIA ONLY WHEN COOL. Turn OFF all electricity to the appliance before installing media.
• If glass media is not installed according to the installation instructions, flame impingement and improper combustion could
occur, resulting in soot and/or excessive production of carbon monoxide (CO), a TOXIC gas that is colorless and odorless.
• This appliance is NOT designed to burn wood. Any attempt to burn wood in this fireplace may be a safety
hazard, cause irreparable damage the appliance, and void the warranty.
1.
Install the glass media in the recessed area between the front and rear floors.
NOTE:
42” fireplaces require a full bag of glass media. 54” fireplaces require two (2) full bags of media.
2.
Spread the glass media in a thin layer, evenly around the burner
(
Figure 51
)
. Do NOT mound the media.
Figure 51 - Installing the glass media
Do NOT place
media on burner or
around pilot.
Glass media area
NOTE:
It is important to ensure proper media placement per the manual when installing these units. Verify pilot
flame is not obstructed. Ensure media does not fall through the pilot hole in the floor. See Verifying Appliance
Operation on
Page 38
.
Installing the Glass Media