Safety measures
Before starting the pump, read this instruction booklet carefully.
• For safety reasons, the pump must not be used by anyone who has not read these instructions.
• The pump must no be used by anyone under 16 years of age.
• Never use the pump if there are people in the water.
• The power cord must never be used to carry or move the pump.
• When handling the pump, while it is connected to the electric power supply, you should avoid all
contact with water.
• Never remove the plug by pulling on the power cord.
• Before taking any action on the pump, always remove the plug from the power socket.
• The pump uses blades to propel the water. These blades revolve at a high speed. Ensure that you
keep your fingers or any other body parts away from the revolving blades.
• Do not use the equipment if there is any damage to it (or any of its parts).
• If the power supply cord has been damaged, it must be replaced by the manufacturer or his
authorized customer support service in order to avoid all risks.
• NEVER let the plug become wet.
• The temperature of the fluid being pumped must never exceed 35° C.
• The pump must not be used to pump salt water, sewage, flammable, corrosive or explosive liquids
(e.g. petroleum oil, petrol, thinner), grease, oils or foodstuffs.
Before starting the pump, make sure that:
• the voltage and frequency specified on the pump’s nameplate coincide with those of the available
power supply;
• there are no signs of damage to the pump or its power cord;
• the electric connection is made in a dry place, protected against any risk of flooding;
• the electric system is complete with a residual current circuit-breaker (
I D
n
#
30 mA) and an
efficient earthing connection;
• the length of the power cord is no more than 10 meters. Any extension cords must
comply with the requirements of the DIN VDE standard 0620.
Note: given the different provisions applicable of the safety of electric systems in different countries,
make sure that the pump system, as concerns its intended use, is in accordance with current
legislation.
Overload protection
The pump has a thermal overload safety device. In the event of any overheating of the motor, this
device automatically switches off the pump. The cooling time is roughly 15 to 20 minutes, then the
pump automatically comes on again. If the overload cutout is tripped, it is essential to identify and
deal with the cause of the overheating.