3. Specifications 

 
2-1.  

Model SC41 Controller Specification 

 
Power  

Input Voltage 

115Vac or 230Vac 

Source 

Output Voltage 

100Vac or 200Vac 

Selection 

Switch 4 

Selects Frequency (3kHz or 6kHz) 

Status 

Indicator 

On – Power on 

External 

VR3 

Adjusts GAIN  

Setting 

VR4 

Adjusts Output Voltage Control 

Housing 

Dimension 

(97.5 x 47 x 150)mm (L X B X H) 

 Case 

Material 

Metal 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

www.fujicon.com.sg 

5

Summary of Contents for SC41

Page 1: ...OPERATIONAL MANUAL FOR CONTROLLER SC41 www fujicon com sg 1 ...

Page 2: ...Contents Page 1 Introduction 1 2 Precaution 2 3 Specifications 3 4 Features 4 5 Input Output 5 6 Control Panel and function 6 7 Preparation 7 8 Operation 8 www fujicon com sg 2 ...

Page 3: ...ration You are requested to keep the operation manual carefully after read This is direct solution to most of the vibratory driver needs for feeder system It is a 4 in 1 controller It has 4 functions which are simple and meeting the basic needs for vibratory driver The functions are 1 AC115V AC230V Input Voltage 2 3 kHz or 6 kHz Frequency Selection 3 Adjustable Gain 4 Adjustable Output Voltage www...

Page 4: ... by the parts feeder after being modified or additionally processed by a third party other than the manufacturer after delivery Specifications and contents of this manual are subject to change without any obligation part of the manufacturer DANGER Electric shock Turn OFF primary power source before any wiring and maintenance DANGER Electric shock Connect the grounding wire green yellow before sett...

Page 5: ... or 230Vac Source Output Voltage 100Vac or 200Vac Selection Switch 4 Selects Frequency 3kHz or 6kHz Status Indicator On Power on External VR3 Adjusts GAIN Setting VR4 Adjusts Output Voltage Control Housing Dimension 97 5 x 47 x 150 mm L X B X H Case Material Metal www fujicon com sg 5 ...

Page 6: ...ing SW4 3 kHz is half wave frequency while 6 kHz is a full wave frequency 4 4 Adjustable GAIN VR3 Adjust GAIN potentiometer to control output voltage range to obtain optimum performance 4 5 Adjustable Output Control Voltage VR4 Adjust the output control voltage 0 10 clockwise to increase output voltage 4 6 Indicator Light Turns on when power supply is on www fujicon com sg 6 ...

Page 7: ... 5 1 Connection FUSE Holder 2 5A 250V Insert fuse here 5 2 Terminal Connection Connect terminal with Live input Brown and output Neutral input Blue and output Ground input Green Yellow and output www fujicon com sg 7 ...

Page 8: ...5 2 Picture Illustration Live wire Brown Earth wire Green Yellow Neutral wire Blue Fuse 2A 250V To feeder www fujicon com sg 8 ...

Page 9: ...r light Indicate power is on ON OFF Switch Switching power on and off GAIN To control the output voltage range Output Voltage Control VR4 to control output voltage correspondently from 0 10 Mounting dismounting screw x 2 Mounting hole www fujicon com sg 9 ...

Page 10: ...ng to the selected AC voltage 230Vac or 115Vac to get ready 7 5 Connect fuse in the fuse holder Insert the fuse properly in the fuse holder in which both side of the fuse must be in contact with the fuse holder 7 6 Select SW4 for 3 kHz or 6 kHz frequency selection Choose 6 kHz for full wave frequency or 3 kHz for half wave frequency 7 7 Check input and output cables for grounding with multimeter t...

Page 11: ...panel to control the output voltage range Adjust VR4 to mid range example 5 turn VR3 to obtain optimum performance 8 3 Adjust VR4 Output Voltage Control to Control Output Voltage The output voltage control in the front panel is use to control the output voltage By turning clockwise the voltage will increase correspondently from 0 to 10 www fujicon com sg 11 ...