S tep2:
Turn off power. Insert the L,N wires
of the J-box into the male connector.
2
S tep6:
Plug the female connector of the
luminaire into the male connector of the AC
input wire.The Ground connects to Green
wire.Dimming wires connect according to
the same wire color.
6
S tep4:
Alight the 2 longer hooks on the metal plate with
the longer hole on the luminaire(Look at the metal palte
and the luminaire with the 'STEP 1' mark). Slightly move
the luminaire forward and make sure the hooks is in
right position.
4
S tep1:
Remove the surface mounted kit
from the luminaire.
1
S tep5:
Fix the metal string on the hook.
(Fig.2)
5
S tep3:
Align the holes on the surface mounted kit with
the hole on the J-box Tighten 2#8-32 screws, rotate
the plate to your right position and lots of KA3.5*20mm
screws into the ceiling and make the kit flush with
the ceiling.
3
Step8:
Push the luminaire on the ceiling. Make
sure the 4 hooks are inside the luminaire and
push forward the luminaire until you hear a
clicking sound.
8-1
S tep7:
Put the wire into the J-box.
7-1
8-2
2
RECESSED INST
ALLA TION
FS SERIES
FS SERIES
INST ALLA TION
Please read this entire manual to fully understand and safely use this product.
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.
NOTE
Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.
UNP ACKING
1
2
3
Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.
READ ALL INSTRUCTIONS BEFORE INST
ALLA TION
1
2
3
4
5
6
7
8
Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in
with relevant local codes.
accordance
Risk of electric shock. Ensure that main power source is off when wiring or soldering the
of the product.
sections
Before installing this fixture or doing any maintenance, make sure to turn off the power
the circuit breaker or fuse box.
supply at
Check to make sure that all fixture connections have been properly made and the fixture
grounded to avoid potential electrical shocks.
is
Do
in water.
not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or
This
conditions to ensure safety to human body.
panel lights are normally set to work at extra low voltage below DC42V and constant current
OPTIONAL
FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**
Suitable for Damp location
. Access above ceiling required. Suitable for suspended ceilings
IMPORT ANT SAFETYINFORMA
TION
CAUTION: Risk of Electric Shock
!
Accessory:
LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )
page 2
page 1
page 4
page 3
RECESSED INST
ALLA TION
Step3:
Turn off power,remove the ceiling panel. Then place
the panel in to the T-bar,ensure he panel is attached to the
ceiling.(Figure3)
Step4:
connect conduit to J-box with proper connector(s).
Remove appropriate round knock-out(s) and
Step5:
tightly.the line connect to the connector with the black
mark, the natural connect to another,the ground connect
to the green wire.(Figure4)
Put a connector to the end of AC input wire and
Step1:
Remove the surface mounted kit
from the luminaire.
Step2:
Same to 4 hang buckles.(Figure 2)
Bend hang buckle by 90° making it vertical to
the rear cover of panel light.
Step7:
Push all wires back into the junction box,Close J-BOX for cap (Figure 5).
please use switch to dim and don’t need to connect the dimming
wire. Dimming step:
Fristly
, Turn on to 100% brightness
Secondly
,It takes about 0.5~2 seconds from turn off the light to
next trun on and lamp is in 50% brightness,
At last
,It takes
about 0.5~2 seconds from turn off the light to next trun on and
lamp 10% brightness. (Figure 7)
Note: For cycle of step dimming, wait until the lamp is in brightness.
For failure of step dimming, turn off the lamp and turn on after 3 second.
For Step Dimming
,
For 0-10V Dimming
The driver PUR (D+) to the (PUR),and the
driver GRY(D-)to the dimmer-(GRY)
Connect the wires with terminal cap as shown in wiring
diagram (Figure 6).
Incoming insulated dimming conductors shall have
voltage rated at least equal to the branch voltage.
Compatible with 0-10V dimmer
Figure1
Figure2
Figure3
Figure4
Figure5
WIRING DIAGRAM
0-10V
Dimmer
D +
D -
PURPLE
GREY
L
N
G
PURPLE
GREY
RED BLACK
BLACK
WHITE
GROUND
LED
PANEL
Dimming
Driver
Figure6
Step Dimming
One Cycle
Note
:
After
3s
turn
on
lamp to
100
%
brightness
.
Turn Off
Lamp
Turn Off
Lamp
Turn Off
Lamp
Turn On
Lamp
10
%
brightness
Turn On
Lamp
50
%
brightness
Turn On
Lamp
100
%
brightness
After 0.5S
At
0
.
5
-
2s
At
0
.
5
-
2s
After 0.5S
After 0.5S
Figure7
To r igh t po s itio n
It is the right pos ition whic h is the
longer hooks of the firs t groove.
7-2
1
2
3
4
R ight pos ition
FS SERIES
Surface Mounted Kit
Installation
FS SERIES
Surface Mounted Kit
Installation
S tep2:
Turn off power. Insert the L,N wires
of the J-box into the male connector.
2
S tep6:
Plug the female connector of the
luminaire into the male connector of the AC
input wire.The Ground connects to Green
wire.Dimming wires connect according to
the same wire color.
6
S tep4:
Alight the 2 longer hooks on the metal plate with
the longer hole on the luminaire(Look at the metal palte
and the luminaire with the 'STEP 1' mark). Slightly move
the luminaire forward and make sure the hooks is in
right position.
4
S tep1:
Remove the surface mounted kit
from the luminaire.
1
S tep5:
Fix the metal string on the hook.
(Fig.2)
5
S tep3:
Align the holes on the surface mounted kit with
the hole on the J-box Tighten 2#8-32 screws, rotate
the plate to your right position and lots of KA3.5*20mm
screws into the ceiling and make the kit flush with
the ceiling.
3
Step8:
Push the luminaire on the ceiling. Make
sure the 4 hooks are inside the luminaire and
push forward the luminaire until you hear a
clicking sound.
8-1
S tep7:
Put the wire into the J-box.
7-1
8-2
2
RECESSED INST
ALLA TION
FS SERIES
FS SERIES
INST ALLA TION
Please read this entire manual to fully understand and safely use this product.
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.
NOTE
Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.
UNP ACKING
1
2
3
Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.
READ ALL INSTRUCTIONS BEFORE INST
ALLA TION
1
2
3
4
5
6
7
8
Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in
with relevant local codes.
accordance
Risk of electric shock. Ensure that main power source is off when wiring or soldering the
of the product.
sections
Before installing this fixture or doing any maintenance, make sure to turn off the power
the circuit breaker or fuse box.
supply at
Check to make sure that all fixture connections have been properly made and the fixture
grounded to avoid potential electrical shocks.
is
Do
in water.
not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or
This
conditions to ensure safety to human body.
panel lights are normally set to work at extra low voltage below DC42V and constant current
OPTIONAL
FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**
Suitable for Damp location
. Access above ceiling required. Suitable for suspended ceilings
IMPORT ANT SAFETYINFORMA
TION
CAUTION: Risk of Electric Shock
!
Accessory:
LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )
page 2
page 1
page 4
page 3
RECESSED INST
ALLA TION
Step3:
Turn off power,remove the ceiling panel. Then place
the panel in to the T-bar,ensure he panel is attached to the
ceiling.(Figure3)
Step4:
connect conduit to J-box with proper connector(s).
Remove appropriate round knock-out(s) and
Step5:
tightly.the line connect to the connector with the black
mark, the natural connect to another,the ground connect
to the green wire.(Figure4)
Put a connector to the end of AC input wire and
Step1:
Remove the surface mounted kit
from the luminaire.
Step2:
Same to 4 hang buckles.(Figure 2)
Bend hang buckle by 90° making it vertical to
the rear cover of panel light.
Step7:
Push all wires back into the junction box,Close J-BOX for cap (Figure 5).
please use switch to dim and don’t need to connect the dimming
wire. Dimming step:
Fristly
, Turn on to 100% brightness
Secondly
,It takes about 0.5~2 seconds from turn off the light to
next trun on and lamp is in 50% brightness,
At last
,It takes
about 0.5~2 seconds from turn off the light to next trun on and
lamp 10% brightness. (Figure 7)
Note: For cycle of step dimming, wait until the lamp is in brightness.
For failure of step dimming, turn off the lamp and turn on after 3 second.
For Step Dimming
,
For 0-10V Dimming
The driver PUR (D+) to the (PUR),and the
driver GRY(D-)to the dimmer-(GRY)
Connect the wires with terminal cap as shown in wiring
diagram (Figure 6).
Incoming insulated dimming conductors shall have
voltage rated at least equal to the branch voltage.
Compatible with 0-10V dimmer
Figure1
Figure2
Figure3
Figure4
Figure5
WIRING DIAGRAM
0-10V
Dimmer
D +
D -
PURPLE
GREY
L
N
G
PURPLE
GREY
RED BLACK
BLACK
WHITE
GROUND
LED
PANEL
Dimming
Driver
Figure6
Step Dimming
One Cycle
Note
:
After
3s
turn
on
lamp to
100
%
brightness
.
Turn Off
Lamp
Turn Off
Lamp
Turn Off
Lamp
Turn On
Lamp
10
%
brightness
Turn On
Lamp
50
%
brightness
Turn On
Lamp
100
%
brightness
After 0.5S
At
0
.
5
-
2s
At
0
.
5
-
2s
After 0.5S
After 0.5S
Figure7
To r igh t po s itio n
It is the right pos ition whic h is the
longer hooks of the firs t groove.
7-2
1
2
3
4
R ight pos ition
FS SERIES
Surface Mounted Kit
Installation
FS SERIES
Surface Mounted Kit
Installation
S tep2:
Turn off power. Insert the L,N wires
of the J-box into the male connector.
2
S tep6:
Plug the female connector of the
luminaire into the male connector of the AC
input wire.The Ground connects to Green
wire.Dimming wires connect according to
the same wire color.
6
S tep4:
Alight the 2 longer hooks on the metal plate with
the longer hole on the luminaire(Look at the metal palte
and the luminaire with the 'STEP 1' mark). Slightly move
the luminaire forward and make sure the hooks is in
right position.
4
S tep1:
Remove the surface mounted kit
from the luminaire.
1
S tep5:
Fix the metal string on the hook.
(Fig.2)
5
S tep3:
Align the holes on the surface mounted kit with
the hole on the J-box Tighten 2#8-32 screws, rotate
the plate to your right position and lots of KA3.5*20mm
screws into the ceiling and make the kit flush with
the ceiling.
3
Step8:
Push the luminaire on the ceiling. Make
sure the 4 hooks are inside the luminaire and
push forward the luminaire until you hear a
clicking sound.
8-1
S tep7:
Put the wire into the J-box.
7-1
8-2
2
RECESSED INST
ALLA TION
FS SERIES
FS SERIES
INST ALLA TION
Please read this entire manual to fully understand and safely use this product.
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.
NOTE
Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.
UNP ACKING
1
2
3
Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.
READ ALL INSTRUCTIONS BEFORE INST
ALLA TION
1
2
3
4
5
6
7
8
Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in
with relevant local codes.
accordance
Risk of electric shock. Ensure that main power source is off when wiring or soldering the
of the product.
sections
Before installing this fixture or doing any maintenance, make sure to turn off the power
the circuit breaker or fuse box.
supply at
Check to make sure that all fixture connections have been properly made and the fixture
grounded to avoid potential electrical shocks.
is
Do
in water.
not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or
This
conditions to ensure safety to human body.
panel lights are normally set to work at extra low voltage below DC42V and constant current
OPTIONAL
FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**
Suitable for Damp location
. Access above ceiling required. Suitable for suspended ceilings
IMPORT ANT SAFETYINFORMA
TION
CAUTION: Risk of Electric Shock
!
Accessory:
LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )
page 2
page 1
page 4
page 3
RECESSED INST
ALLA TION
Step3:
Turn off power,remove the ceiling panel. Then place
the panel in to the T-bar,ensure he panel is attached to the
ceiling.(Figure3)
Step4:
connect conduit to J-box with proper connector(s).
Remove appropriate round knock-out(s) and
Step5:
tightly.the line connect to the connector with the black
mark, the natural connect to another,the ground connect
to the green wire.(Figure4)
Put a connector to the end of AC input wire and
Step1:
Remove the surface mounted kit
from the luminaire.
Step2:
Same to 4 hang buckles.(Figure 2)
Bend hang buckle by 90° making it vertical to
the rear cover of panel light.
Step7:
Push all wires back into the junction box,Close J-BOX for cap (Figure 5).
please use switch to dim and don’t need to connect the dimming
wire. Dimming step:
Fristly
, Turn on to 100% brightness
Secondly
,It takes about 0.5~2 seconds from turn off the light to
next trun on and lamp is in 50% brightness,
At last
,It takes
about 0.5~2 seconds from turn off the light to next trun on and
lamp 10% brightness. (Figure 7)
Note: For cycle of step dimming, wait until the lamp is in brightness.
For failure of step dimming, turn off the lamp and turn on after 3 second.
For Step Dimming
,
For 0-10V Dimming
The driver PUR (D+) to the (PUR),and the
driver GRY(D-)to the dimmer-(GRY)
Connect the wires with terminal cap as shown in wiring
diagram (Figure 6).
Incoming insulated dimming conductors shall have
voltage rated at least equal to the branch voltage.
Compatible with 0-10V dimmer
Figure1
Figure2
Figure3
Figure4
Figure5
WIRING DIAGRAM
0-10V
Dimmer
D +
D -
PURPLE
GREY
L
N
G
PURPLE
GREY
RED BLACK
BLACK
WHITE
GROUND
LED
PANEL
Dimming
Driver
Figure6
Step Dimming
One Cycle
Note
:
After
3s
turn
on
lamp to
100
%
brightness
.
Turn Off
Lamp
Turn Off
Lamp
Turn Off
Lamp
Turn On
Lamp
10
%
brightness
Turn On
Lamp
50
%
brightness
Turn On
Lamp
100
%
brightness
After 0.5S
At
0
.
5
-
2s
At
0
.
5
-
2s
After 0.5S
After 0.5S
Figure7
To r igh t po s itio n
It is the right pos ition whic h is the
longer hooks of the firs t groove.
7-2
1
2
3
4
R ight pos ition
FS SERIES
Surface Mounted Kit
Installation
FS SERIES
Surface Mounted Kit
Installation
S tep2:
Turn off power. Insert the L,N wires
of the J-box into the male connector.
2
S tep6:
Plug the female connector of the
luminaire into the male connector of the AC
input wire.The Ground connects to Green
wire.Dimming wires connect according to
the same wire color.
6
S tep4:
Alight the 2 longer hooks on the metal plate with
the longer hole on the luminaire(Look at the metal palte
and the luminaire with the 'STEP 1' mark). Slightly move
the luminaire forward and make sure the hooks is in
right position.
4
S tep1:
Remove the surface mounted kit
from the luminaire.
1
S tep5:
Fix the metal string on the hook.
(Fig.2)
5
S tep3:
Align the holes on the surface mounted kit with
the hole on the J-box Tighten 2#8-32 screws, rotate
the plate to your right position and lots of KA3.5*20mm
screws into the ceiling and make the kit flush with
the ceiling.
3
Step8:
Push the luminaire on the ceiling. Make
sure the 4 hooks are inside the luminaire and
push forward the luminaire until you hear a
clicking sound.
8-1
S tep7:
Put the wire into the J-box.
7-1
8-2
2
RECESSED INST
ALLA TION
FS SERIES
FS SERIES
INST ALLA TION
Please read this entire manual to fully understand and safely use this product.
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.
NOTE
Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.
UNP ACKING
1
2
3
Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.
READ ALL INSTRUCTIONS BEFORE INST
ALLA TION
1
2
3
4
5
6
7
8
Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in
with relevant local codes.
accordance
Risk of electric shock. Ensure that main power source is off when wiring or soldering the
of the product.
sections
Before installing this fixture or doing any maintenance, make sure to turn off the power
the circuit breaker or fuse box.
supply at
Check to make sure that all fixture connections have been properly made and the fixture
grounded to avoid potential electrical shocks.
is
Do
in water.
not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or
This
conditions to ensure safety to human body.
panel lights are normally set to work at extra low voltage below DC42V and constant current
OPTIONAL
FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**
Suitable for Damp location
. Access above ceiling required. Suitable for suspended ceilings
IMPORT ANT SAFETYINFORMA
TION
CAUTION: Risk of Electric Shock
!
Accessory:
LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )
page 2
page 1
page 4
page 3
RECESSED INST
ALLA TION
Step3:
Turn off power,remove the ceiling panel. Then place
the panel in to the T-bar,ensure he panel is attached to the
ceiling.(Figure3)
Step4:
connect conduit to J-box with proper connector(s).
Remove appropriate round knock-out(s) and
Step5:
tightly.the line connect to the connector with the black
mark, the natural connect to another,the ground connect
to the green wire.(Figure4)
Put a connector to the end of AC input wire and
Step1:
Remove the surface mounted kit
from the luminaire.
Step2:
Same to 4 hang buckles.(Figure 2)
Bend hang buckle by 90° making it vertical to
the rear cover of panel light.
Step7:
Push all wires back into the junction box,Close J-BOX for cap (Figure 5).
please use switch to dim and don’t need to connect the dimming
wire. Dimming step:
Fristly
, Turn on to 100% brightness
Secondly
,It takes about 0.5~2 seconds from turn off the light to
next trun on and lamp is in 50% brightness,
At last
,It takes
about 0.5~2 seconds from turn off the light to next trun on and
lamp 10% brightness. (Figure 7)
Note: For cycle of step dimming, wait until the lamp is in brightness.
For failure of step dimming, turn off the lamp and turn on after 3 second.
For Step Dimming
,
For 0-10V Dimming
The driver PUR (D+) to the (PUR),and the
driver GRY(D-)to the dimmer-(GRY)
Connect the wires with terminal cap as shown in wiring
diagram (Figure 6).
Incoming insulated dimming conductors shall have
voltage rated at least equal to the branch voltage.
Compatible with 0-10V dimmer
Figure1
Figure2
Figure3
Figure4
Figure5
WIRING DIAGRAM
0-10V
Dimmer
D +
D -
PURPLE
GREY
L
N
G
PURPLE
GREY
RED BLACK
BLACK
WHITE
GROUND
LED
PANEL
Dimming
Driver
Figure6
Step Dimming
One Cycle
Note
:
After
3s
turn
on
lamp to
100
%
brightness
.
Turn Off
Lamp
Turn Off
Lamp
Turn Off
Lamp
Turn On
Lamp
10
%
brightness
Turn On
Lamp
50
%
brightness
Turn On
Lamp
100
%
brightness
After 0.5S
At
0
.
5
-
2s
At
0
.
5
-
2s
After 0.5S
After 0.5S
Figure7
To r igh t po s itio n
It is the right pos ition whic h is the
longer hooks of the firs t groove.
7-2
1
2
3
4
R ight pos ition
FS SERIES
Surface Mounted Kit
Installation
FS SERIES
Surface Mounted Kit
Installation
S tep2:
Turn off power. Insert the L,N wires
of the J-box into the male connector.
2
S tep6:
Plug the female connector of the
luminaire into the male connector of the AC
input wire.The Ground connects to Green
wire.Dimming wires connect according to
the same wire color.
6
S tep4:
Alight the 2 longer hooks on the metal plate with
the longer hole on the luminaire(Look at the metal palte
and the luminaire with the 'STEP 1' mark). Slightly move
the luminaire forward and make sure the hooks is in
right position.
4
S tep1:
Remove the surface mounted kit
from the luminaire.
1
S tep5:
Fix the metal string on the hook.
(Fig.2)
5
S tep3:
Align the holes on the surface mounted kit with
the hole on the J-box Tighten 2#8-32 screws, rotate
the plate to your right position and lots of KA3.5*20mm
screws into the ceiling and make the kit flush with
the ceiling.
3
Step8:
Push the luminaire on the ceiling. Make
sure the 4 hooks are inside the luminaire and
push forward the luminaire until you hear a
clicking sound.
8-1
S tep7:
Put the wire into the J-box.
7-1
8-2
2
RECESSED INST
ALLA TION
FS SERIES
FS SERIES
INST ALLA TION
Please read this entire manual to fully understand and safely use this product.
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.
NOTE
Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.
UNP ACKING
1
2
3
Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.
READ ALL INSTRUCTIONS BEFORE INST
ALLA TION
1
2
3
4
5
6
7
8
Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in
with relevant local codes.
accordance
Risk of electric shock. Ensure that main power source is off when wiring or soldering the
of the product.
sections
Before installing this fixture or doing any maintenance, make sure to turn off the power
the circuit breaker or fuse box.
supply at
Check to make sure that all fixture connections have been properly made and the fixture
grounded to avoid potential electrical shocks.
is
Do
in water.
not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or
This
conditions to ensure safety to human body.
panel lights are normally set to work at extra low voltage below DC42V and constant current
OPTIONAL
FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**
Suitable for Damp location
. Access above ceiling required. Suitable for suspended ceilings
IMPORT ANT SAFETYINFORMA
TION
CAUTION: Risk of Electric Shock
!
Accessory:
LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )
page 2
page 1
page 4
page 3
RECESSED INST
ALLA TION
Step3:
Turn off power,remove the ceiling panel. Then place
the panel in to the T-bar,ensure he panel is attached to the
ceiling.(Figure3)
Step4:
connect conduit to J-box with proper connector(s).
Remove appropriate round knock-out(s) and
Step5:
tightly.the line connect to the connector with the black
mark, the natural connect to another,the ground connect
to the green wire.(Figure4)
Put a connector to the end of AC input wire and
Step1:
Remove the surface mounted kit
from the luminaire.
Step2:
Same to 4 hang buckles.(Figure 2)
Bend hang buckle by 90° making it vertical to
the rear cover of panel light.
Step7:
Push all wires back into the junction box,Close J-BOX for cap (Figure 5).
please use switch to dim and don’t need to connect the dimming
wire. Dimming step:
Fristly
, Turn on to 100% brightness
Secondly
,It takes about 0.5~2 seconds from turn off the light to
next trun on and lamp is in 50% brightness,
At last
,It takes
about 0.5~2 seconds from turn off the light to next trun on and
lamp 10% brightness. (Figure 7)
Note: For cycle of step dimming, wait until the lamp is in brightness.
For failure of step dimming, turn off the lamp and turn on after 3 second.
For Step Dimming
,
For 0-10V Dimming
The driver PUR (D+) to the (PUR),and the
driver GRY(D-)to the dimmer-(GRY)
Connect the wires with terminal cap as shown in wiring
diagram (Figure 6).
Incoming insulated dimming conductors shall have
voltage rated at least equal to the branch voltage.
Compatible with 0-10V dimmer
Figure1
Figure2
Figure3
Figure4
Figure5
WIRING DIAGRAM
0-10V
Dimmer
D +
D -
PURPLE
GREY
L
N
G
PURPLE
GREY
RED BLACK
BLACK
WHITE
GROUND
LED
PANEL
Dimming
Driver
Figure6
Step Dimming
One Cycle
Note
:
After
3s
turn
on
lamp to
100
%
brightness
.
Turn Off
Lamp
Turn Off
Lamp
Turn Off
Lamp
Turn On
Lamp
10
%
brightness
Turn On
Lamp
50
%
brightness
Turn On
Lamp
100
%
brightness
After 0.5S
At
0
.
5
-
2s
At
0
.
5
-
2s
After 0.5S
After 0.5S
Figure7
To r igh t po s itio n
It is the right pos ition whic h is the
longer hooks of the firs t groove.
7-2
1
2
3
4
R ight pos ition
FS SERIES
Surface Mounted Kit
Installation
FS SERIES
Surface Mounted Kit
Installation
S tep2:
Turn off power. Insert the L,N wires
of the J-box into the male connector.
2
S tep6:
Plug the female connector of the
luminaire into the male connector of the AC
input wire.The Ground connects to Green
wire.Dimming wires connect according to
the same wire color.
6
S tep4:
Alight the 2 longer hooks on the metal plate with
the longer hole on the luminaire(Look at the metal palte
and the luminaire with the 'STEP 1' mark). Slightly move
the luminaire forward and make sure the hooks is in
right position.
4
S tep1:
Remove the surface mounted kit
from the luminaire.
1
S tep5:
Fix the metal string on the hook.
(Fig.2)
5
S tep3:
Align the holes on the surface mounted kit with
the hole on the J-box Tighten 2#8-32 screws, rotate
the plate to your right position and lots of KA3.5*20mm
screws into the ceiling and make the kit flush with
the ceiling.
3
Step8:
Push the luminaire on the ceiling. Make
sure the 4 hooks are inside the luminaire and
push forward the luminaire until you hear a
clicking sound.
8-1
S tep7:
Put the wire into the J-box.
7-1
8-2
2
RECESSED INST
ALLA TION
FS SERIES
FS SERIES
INST ALLA TION
Please read this entire manual to fully understand and safely use this product.
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.
NOTE
Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.
UNP ACKING
1
2
3
Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.
READ ALL INSTRUCTIONS BEFORE INST
ALLA TION
1
2
3
4
5
6
7
8
Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in
with relevant local codes.
accordance
Risk of electric shock. Ensure that main power source is off when wiring or soldering the
of the product.
sections
Before installing this fixture or doing any maintenance, make sure to turn off the power
the circuit breaker or fuse box.
supply at
Check to make sure that all fixture connections have been properly made and the fixture
grounded to avoid potential electrical shocks.
is
Do
in water.
not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or
This
conditions to ensure safety to human body.
panel lights are normally set to work at extra low voltage below DC42V and constant current
OPTIONAL
FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**
Suitable for Damp location
. Access above ceiling required. Suitable for suspended ceilings
IMPORT ANT SAFETYINFORMA
TION
CAUTION: Risk of Electric Shock
!
Accessory:
LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )
page 2
page 1
page 4
page 3
RECESSED INST
ALLA TION
Step3:
Turn off power,remove the ceiling panel. Then place
the panel in to the T-bar,ensure he panel is attached to the
ceiling.(Figure3)
Step4:
connect conduit to J-box with proper connector(s).
Remove appropriate round knock-out(s) and
Step5:
tightly.the line connect to the connector with the black
mark, the natural connect to another,the ground connect
to the green wire.(Figure4)
Put a connector to the end of AC input wire and
Step1:
Remove the surface mounted kit
from the luminaire.
Step2:
Same to 4 hang buckles.(Figure 2)
Bend hang buckle by 90° making it vertical to
the rear cover of panel light.
Step7:
Push all wires back into the junction box,Close J-BOX for cap (Figure 5).
please use switch to dim and don’t need to connect the dimming
wire. Dimming step:
Fristly
, Turn on to 100% brightness
Secondly
,It takes about 0.5~2 seconds from turn off the light to
next trun on and lamp is in 50% brightness,
At last
,It takes
about 0.5~2 seconds from turn off the light to next trun on and
lamp 10% brightness. (Figure 7)
Note: For cycle of step dimming, wait until the lamp is in brightness.
For failure of step dimming, turn off the lamp and turn on after 3 second.
For Step Dimming
,
For 0-10V Dimming
The driver PUR (D+) to the (PUR),and the
driver GRY(D-)to the dimmer-(GRY)
Connect the wires with terminal cap as shown in wiring
diagram (Figure 6).
Incoming insulated dimming conductors shall have
voltage rated at least equal to the branch voltage.
Compatible with 0-10V dimmer
Figure1
Figure2
Figure3
Figure4
Figure5
WIRING DIAGRAM
0-10V
Dimmer
D +
D -
PURPLE
GREY
L
N
G
PURPLE
GREY
RED BLACK
BLACK
WHITE
GROUND
LED
PANEL
Dimming
Driver
Figure6
Step Dimming
One Cycle
Note
:
After
3s
turn
on
lamp to
100
%
brightness
.
Turn Off
Lamp
Turn Off
Lamp
Turn Off
Lamp
Turn On
Lamp
10
%
brightness
Turn On
Lamp
50
%
brightness
Turn On
Lamp
100
%
brightness
After 0.5S
At
0
.
5
-
2s
At
0
.
5
-
2s
After 0.5S
After 0.5S
Figure7
To r igh t po s itio n
It is the right pos ition whic h is the
longer hooks of the firs t groove.
7-2
1
2
3
4
R ight pos ition
FS SERIES
Surface Mounted Kit
Installation
FS SERIES
Surface Mounted Kit
Installation
S tep2:
Turn off power. Insert the L,N wires
of the J-box into the male connector.
2
S tep6:
Plug the female connector of the
luminaire into the male connector of the AC
input wire.The Ground connects to Green
wire.Dimming wires connect according to
the same wire color.
6
S tep4:
Alight the 2 longer hooks on the metal plate with
the longer hole on the luminaire(Look at the metal palte
and the luminaire with the 'STEP 1' mark). Slightly move
the luminaire forward and make sure the hooks is in
right position.
4
S tep1:
Remove the surface mounted kit
from the luminaire.
1
S tep5:
Fix the metal string on the hook.
(Fig.2)
5
S tep3:
Align the holes on the surface mounted kit with
the hole on the J-box Tighten 2#8-32 screws, rotate
the plate to your right position and lots of KA3.5*20mm
screws into the ceiling and make the kit flush with
the ceiling.
3
Step8:
Push the luminaire on the ceiling. Make
sure the 4 hooks are inside the luminaire and
push forward the luminaire until you hear a
clicking sound.
8-1
S tep7:
Put the wire into the J-box.
7-1
8-2
2
RECESSED INST
ALLA TION
FS SERIES
FS SERIES
INST ALLA TION
Please read this entire manual to fully understand and safely use this product.
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.
NOTE
Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.
UNP ACKING
1
2
3
Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.
READ ALL INSTRUCTIONS BEFORE INST
ALLA TION
1
2
3
4
5
6
7
8
Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in
with relevant local codes.
accordance
Risk of electric shock. Ensure that main power source is off when wiring or soldering the
of the product.
sections
Before installing this fixture or doing any maintenance, make sure to turn off the power
the circuit breaker or fuse box.
supply at
Check to make sure that all fixture connections have been properly made and the fixture
grounded to avoid potential electrical shocks.
is
Do
in water.
not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or
This
conditions to ensure safety to human body.
panel lights are normally set to work at extra low voltage below DC42V and constant current
OPTIONAL
FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**
Suitable for Damp location
. Access above ceiling required. Suitable for suspended ceilings
IMPORT ANT SAFETYINFORMA
TION
CAUTION: Risk of Electric Shock
!
Accessory:
LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )
page 2
page 1
page 4
page 3
RECESSED INST
ALLA TION
Step3:
Turn off power,remove the ceiling panel. Then place
the panel in to the T-bar,ensure he panel is attached to the
ceiling.(Figure3)
Step4:
connect conduit to J-box with proper connector(s).
Remove appropriate round knock-out(s) and
Step5:
tightly.the line connect to the connector with the black
mark, the natural connect to another,the ground connect
to the green wire.(Figure4)
Put a connector to the end of AC input wire and
Step1:
Remove the surface mounted kit
from the luminaire.
Step2:
Same to 4 hang buckles.(Figure 2)
Bend hang buckle by 90° making it vertical to
the rear cover of panel light.
Step7:
Push all wires back into the junction box,Close J-BOX for cap (Figure 5).
please use switch to dim and don’t need to connect the dimming
wire. Dimming step:
Fristly
, Turn on to 100% brightness
Secondly
,It takes about 0.5~2 seconds from turn off the light to
next trun on and lamp is in 50% brightness,
At last
,It takes
about 0.5~2 seconds from turn off the light to next trun on and
lamp 10% brightness. (Figure 7)
Note: For cycle of step dimming, wait until the lamp is in brightness.
For failure of step dimming, turn off the lamp and turn on after 3 second.
For Step Dimming
,
For 0-10V Dimming
The driver PUR (D+) to the (PUR),and the
driver GRY(D-)to the dimmer-(GRY)
Connect the wires with terminal cap as shown in wiring
diagram (Figure 6).
Incoming insulated dimming conductors shall have
voltage rated at least equal to the branch voltage.
Compatible with 0-10V dimmer
Figure1
Figure2
Figure3
Figure4
Figure5
WIRING DIAGRAM
0-10V
Dimmer
D +
D -
PURPLE
GREY
L
N
G
PURPLE
GREY
RED BLACK
BLACK
WHITE
GROUND
LED
PANEL
Dimming
Driver
Figure6
Step Dimming
One Cycle
Note
:
After
3s
turn
on
lamp to
100
%
brightness
.
Turn Off
Lamp
Turn Off
Lamp
Turn Off
Lamp
Turn On
Lamp
10
%
brightness
Turn On
Lamp
50
%
brightness
Turn On
Lamp
100
%
brightness
After 0.5S
At
0
.
5
-
2s
At
0
.
5
-
2s
After 0.5S
After 0.5S
Figure7
To r igh t po s itio n
It is the right pos ition whic h is the
longer hooks of the firs t groove.
7-2
1
2
3
4
R ight pos ition
1. Remove Surface Mounting Kit and panel
from packaging.
2. Turn off power and run supply wiring
through J-box. Insert supply line and neutral
power wires into corresponding locations on
orange quick disconnect. Line is labeled in
black, neutral is white. (Fig. 2)
3. Temporarily attach Surface Mounting Kit to
J-box and align to the desired orientation. Mark
screw holes and drill pilot holes then remove
Surface Mounting Kit. Insert screw anchors into
mounting surface at marks. Reinstall Surface
Mounting Kit to junction box and install screws to
screw anchors. (Fig. 3)
4. Screw Steel Cable Service Loop to light
panel (see Fig.5). Align the longer hooks
labeled “Step 1” on the Surface Mounting
Bracket to the larger slots along the edge of
the panel backing labeled “Step 1” and slide to
the fi rst notch. (Fig. 4)
5. Attach the Steel Cable Service Loop from the
panel to one of the Surface Mount Kit hooks.
Loop holds the panel while wiring. (Fig. 5)
6. Connect the green ground wire to supply
ground wire. Connect the two orange quick
disconnects together. Connect the 0~10V
dimming wires according to the Wiring
Diagram with wire nuts. (Fig. 6)
7. Tuck wiring into junction box being sure not to
pinch wires. (Fig. 7-1 & 7-2)
8. Lift panel onto remaining hooks on Surface
Mounting Bracket while aligning to remaining
slots on panel. Slide panel the same direction
as step 4 until the panel locks into the second
notch. (Fig. 8-1 & 8-2)
Screw
Screw
• This product should be installed by a fully
certifi ed electrician in accordance with local
building and electrical codes
•
Due to risk of electric shock, ensure that the
main power source and circuit breakers are
switched off before performing any installation
or wiring procedures
•
Do not install insulation within 2 in / 51mm of
any part of the panel light fi xture.
Safety Information
CAUTION! Risk Of Electric Shock
Turn off all power prior to installation
by switching off circuit breaker or
removing fuse at fuse box.