background image

User Manual

Part Number:

4400 Earth City Expy, St. Louis, MO 63045          

866-590-3533            superbrightleds.com

Surface Mounted Kit Installation

LPD-40K22-40

Surface Mounting Kit: LPD-SMK22

Recessed Mounting Kit: LPD-JBK

Rev Date: V1 08/04/2016

FS SERIES

Surface Mounted Kit 

 

Installation

FS SERIES

Surface Mounted Kit 

 

Installation

S tep2: 

Turn off power. Insert the L,N wires

of the J-box into the male connector.

2

S tep6:

Plug the female connector of the 

luminaire into the male connector of the AC 

input wire.The Ground connects to Green 

wire.Dimming wires connect according to 

the same wire color.

6

S tep4:

Alight the 2 longer hooks on the metal plate with 

the longer hole on the luminaire(Look at the metal palte 

and the luminaire with the 'STEP 1' mark). Slightly move 

the luminaire forward and make sure the hooks is in 

right position.

4

S tep1:

 Remove the surface mounted kit 

from the luminaire.

1

S tep5: 

Fix the metal string on the hook.

(Fig.2)

5

S tep3:

Align the holes on the surface mounted kit with

the hole on the J-box Tighten 2#8-32 screws, rotate

the plate to your right position and lots of KA3.5*20mm

screws into the ceiling and make the kit flush with

the ceiling.

3

Step8:

Push the luminaire on the ceiling. Make

sure the 4 hooks are inside the luminaire and 

push forward the luminaire until you hear a 

clicking sound.

8-1

S tep7:

Put the wire into the J-box.

7-1

8-2

2

RECESSED INST

ALLA TION

FS SERIES

FS SERIES

 INST ALLA TION

Please read this entire manual to fully understand and safely use this product. 
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.

NOTE

Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.

UNP ACKING

1

2

3

Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.

READ  ALL  INSTRUCTIONS BEFORE INST

ALLA TION

1
2

3

4

5

6

7

8

Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in 

with relevant local codes.

accordance 

Risk of electric shock. Ensure that main power source is off when wiring or soldering the 

of the product.

sections 

Before installing this fixture or doing any maintenance, make sure to turn off the power 

the circuit breaker or fuse box.

supply at 

Check to make sure that all fixture connections have been properly made and the fixture 

grounded to avoid potential electrical shocks. 

is 

Do 

in water.

not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or 

This 

conditions to ensure safety to human body.

panel lights are normally set to work at extra low voltage below DC42V and constant current 

OPTIONAL

FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**

Suitable for Damp location

. Access above ceiling required. Suitable for suspended ceilings

IMPORT ANT SAFETYINFORMA

TION

CAUTION: Risk of Electric Shock

!

Accessory:

LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )

page 2

page 1

page 4

page 3

RECESSED INST

ALLA TION

Step3: 

Turn off power,remove the ceiling panel. Then place 

the panel in to the T-bar,ensure he panel is attached to the 

ceiling.(Figure3)

Step4:

connect conduit to J-box with proper connector(s).

Remove appropriate round knock-out(s) and 

Step5:

tightly.the line connect to the connector with the black

mark, the natural connect to another,the ground connect

to the green wire.(Figure4)

Put a connector to the end of AC input wire and               

  

Step1: 

Remove the surface mounted kit 

 

from the luminaire.

                                                                   

Step2: 

Same to 4 hang buckles.(Figure 2)

Bend hang buckle by 90° making it vertical to

the rear cover of panel light. 

Step7:

Push all wires back into the junction box,Close J-BOX for cap  (Figure 5).

 

please use switch to dim and don’t need to connect the dimming

wire. Dimming step: 

Fristly

, Turn on to 100% brightness

Secondly

,It takes about 0.5~2 seconds from turn off the light to 

next trun on and  lamp is in 50% brightness, 

At last 

,It takes 

about 0.5~2 seconds from turn off the light to next trun on  and  

lamp 10% brightness. (Figure 7)

Note: For cycle of step dimming, wait until the lamp is in brightness. 

For failure of step dimming, turn off the lamp and turn on after 3 second.

 

For Step Dimming

,

 For 0-10V Dimming

The driver PUR (D+) to the (PUR),and the 

driver GRY(D-)to the dimmer-(GRY)

Connect the wires with terminal cap as shown in wiring 

diagram (Figure 6).
Incoming insulated dimming conductors shall have 

voltage rated at least equal to the branch voltage.

  

Compatible with 0-10V dimmer

Figure1

Figure2

Figure3

Figure4

Figure5

WIRING DIAGRAM

0-10V

Dimmer

D +

D -

PURPLE

GREY

L
N
G

PURPLE

GREY

RED         BLACK

BLACK
WHITE
GROUND

LED 

PANEL

Dimming

Driver

Figure6

Step Dimming

One Cycle

Note

After

 

3s

 

turn

 

on

 

lamp to

 

100

brightness

.

Turn Off 

Lamp

Turn Off 

Lamp

Turn Off

Lamp

Turn On 

Lamp

10

brightness

Turn On 

Lamp

50

brightness

Turn On 

Lamp

100

brightness

After 0.5S

At

 

0

.

5

-

2s

At

 

0

.

5

-

2s

After 0.5S

After 0.5S

Figure7

To  r igh t po s itio n

It is  the right pos ition whic h is  the 

longer hooks  of the firs t groove.

7-2

1

2

3

4

R ight pos ition

FS SERIES

Surface Mounted Kit 

 

Installation

FS SERIES

Surface Mounted Kit 

 

Installation

S tep2: 

Turn off power. Insert the L,N wires

of the J-box into the male connector.

2

S tep6:

Plug the female connector of the 

luminaire into the male connector of the AC 

input wire.The Ground connects to Green 

wire.Dimming wires connect according to 

the same wire color.

6

S tep4:

Alight the 2 longer hooks on the metal plate with 

the longer hole on the luminaire(Look at the metal palte 

and the luminaire with the 'STEP 1' mark). Slightly move 

the luminaire forward and make sure the hooks is in 

right position.

4

S tep1:

 Remove the surface mounted kit 

from the luminaire.

1

S tep5: 

Fix the metal string on the hook.

(Fig.2)

5

S tep3:

Align the holes on the surface mounted kit with

the hole on the J-box Tighten 2#8-32 screws, rotate

the plate to your right position and lots of KA3.5*20mm

screws into the ceiling and make the kit flush with

the ceiling.

3

Step8:

Push the luminaire on the ceiling. Make

sure the 4 hooks are inside the luminaire and 

push forward the luminaire until you hear a 

clicking sound.

8-1

S tep7:

Put the wire into the J-box.

7-1

8-2

2

RECESSED INST

ALLA TION

FS SERIES

FS SERIES

 INST ALLA TION

Please read this entire manual to fully understand and safely use this product. 
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.

NOTE

Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.

UNP ACKING

1

2

3

Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.

READ  ALL  INSTRUCTIONS BEFORE INST

ALLA TION

1
2

3

4

5

6

7

8

Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in 

with relevant local codes.

accordance 

Risk of electric shock. Ensure that main power source is off when wiring or soldering the 

of the product.

sections 

Before installing this fixture or doing any maintenance, make sure to turn off the power 

the circuit breaker or fuse box.

supply at 

Check to make sure that all fixture connections have been properly made and the fixture 

grounded to avoid potential electrical shocks. 

is 

Do 

in water.

not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or 

This 

conditions to ensure safety to human body.

panel lights are normally set to work at extra low voltage below DC42V and constant current 

OPTIONAL

FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**

Suitable for Damp location

. Access above ceiling required. Suitable for suspended ceilings

IMPORT ANT SAFETYINFORMA

TION

CAUTION: Risk of Electric Shock

!

Accessory:

LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )

page 2

page 1

page 4

page 3

RECESSED INST

ALLA TION

Step3: 

Turn off power,remove the ceiling panel. Then place 

the panel in to the T-bar,ensure he panel is attached to the 

ceiling.(Figure3)

Step4:

connect conduit to J-box with proper connector(s).

Remove appropriate round knock-out(s) and 

Step5:

tightly.the line connect to the connector with the black

mark, the natural connect to another,the ground connect

to the green wire.(Figure4)

Put a connector to the end of AC input wire and               

  

Step1: 

Remove the surface mounted kit 

 

from the luminaire.

                                                                   

Step2: 

Same to 4 hang buckles.(Figure 2)

Bend hang buckle by 90° making it vertical to

the rear cover of panel light. 

Step7:

Push all wires back into the junction box,Close J-BOX for cap  (Figure 5).

 

please use switch to dim and don’t need to connect the dimming

wire. Dimming step: 

Fristly

, Turn on to 100% brightness

Secondly

,It takes about 0.5~2 seconds from turn off the light to 

next trun on and  lamp is in 50% brightness, 

At last 

,It takes 

about 0.5~2 seconds from turn off the light to next trun on  and  

lamp 10% brightness. (Figure 7)

Note: For cycle of step dimming, wait until the lamp is in brightness. 

For failure of step dimming, turn off the lamp and turn on after 3 second.

 

For Step Dimming

,

 For 0-10V Dimming

The driver PUR (D+) to the (PUR),and the 

driver GRY(D-)to the dimmer-(GRY)

Connect the wires with terminal cap as shown in wiring 

diagram (Figure 6).
Incoming insulated dimming conductors shall have 

voltage rated at least equal to the branch voltage.

  

Compatible with 0-10V dimmer

Figure1

Figure2

Figure3

Figure4

Figure5

WIRING DIAGRAM

0-10V

Dimmer

D +

D -

PURPLE

GREY

L
N
G

PURPLE

GREY

RED         BLACK

BLACK
WHITE
GROUND

LED 

PANEL

Dimming

Driver

Figure6

Step Dimming

One Cycle

Note

After

 

3s

 

turn

 

on

 

lamp to

 

100

brightness

.

Turn Off 

Lamp

Turn Off 

Lamp

Turn Off

Lamp

Turn On 

Lamp

10

brightness

Turn On 

Lamp

50

brightness

Turn On 

Lamp

100

brightness

After 0.5S

At

 

0

.

5

-

2s

At

 

0

.

5

-

2s

After 0.5S

After 0.5S

Figure7

To  r igh t po s itio n

It is  the right pos ition whic h is  the 

longer hooks  of the firs t groove.

7-2

1

2

3

4

R ight pos ition

FS SERIES

Surface Mounted Kit 

 

Installation

FS SERIES

Surface Mounted Kit 

 

Installation

S tep2: 

Turn off power. Insert the L,N wires

of the J-box into the male connector.

2

S tep6:

Plug the female connector of the 

luminaire into the male connector of the AC 

input wire.The Ground connects to Green 

wire.Dimming wires connect according to 

the same wire color.

6

S tep4:

Alight the 2 longer hooks on the metal plate with 

the longer hole on the luminaire(Look at the metal palte 

and the luminaire with the 'STEP 1' mark). Slightly move 

the luminaire forward and make sure the hooks is in 

right position.

4

S tep1:

 Remove the surface mounted kit 

from the luminaire.

1

S tep5: 

Fix the metal string on the hook.

(Fig.2)

5

S tep3:

Align the holes on the surface mounted kit with

the hole on the J-box Tighten 2#8-32 screws, rotate

the plate to your right position and lots of KA3.5*20mm

screws into the ceiling and make the kit flush with

the ceiling.

3

Step8:

Push the luminaire on the ceiling. Make

sure the 4 hooks are inside the luminaire and 

push forward the luminaire until you hear a 

clicking sound.

8-1

S tep7:

Put the wire into the J-box.

7-1

8-2

2

RECESSED INST

ALLA TION

FS SERIES

FS SERIES

 INST ALLA TION

Please read this entire manual to fully understand and safely use this product. 
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.

NOTE

Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.

UNP ACKING

1

2

3

Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.

READ  ALL  INSTRUCTIONS BEFORE INST

ALLA TION

1
2

3

4

5

6

7

8

Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in 

with relevant local codes.

accordance 

Risk of electric shock. Ensure that main power source is off when wiring or soldering the 

of the product.

sections 

Before installing this fixture or doing any maintenance, make sure to turn off the power 

the circuit breaker or fuse box.

supply at 

Check to make sure that all fixture connections have been properly made and the fixture 

grounded to avoid potential electrical shocks. 

is 

Do 

in water.

not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or 

This 

conditions to ensure safety to human body.

panel lights are normally set to work at extra low voltage below DC42V and constant current 

OPTIONAL

FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**

Suitable for Damp location

. Access above ceiling required. Suitable for suspended ceilings

IMPORT ANT SAFETYINFORMA

TION

CAUTION: Risk of Electric Shock

!

Accessory:

LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )

page 2

page 1

page 4

page 3

RECESSED INST

ALLA TION

Step3: 

Turn off power,remove the ceiling panel. Then place 

the panel in to the T-bar,ensure he panel is attached to the 

ceiling.(Figure3)

Step4:

connect conduit to J-box with proper connector(s).

Remove appropriate round knock-out(s) and 

Step5:

tightly.the line connect to the connector with the black

mark, the natural connect to another,the ground connect

to the green wire.(Figure4)

Put a connector to the end of AC input wire and               

  

Step1: 

Remove the surface mounted kit 

 

from the luminaire.

                                                                   

Step2: 

Same to 4 hang buckles.(Figure 2)

Bend hang buckle by 90° making it vertical to

the rear cover of panel light. 

Step7:

Push all wires back into the junction box,Close J-BOX for cap  (Figure 5).

 

please use switch to dim and don’t need to connect the dimming

wire. Dimming step: 

Fristly

, Turn on to 100% brightness

Secondly

,It takes about 0.5~2 seconds from turn off the light to 

next trun on and  lamp is in 50% brightness, 

At last 

,It takes 

about 0.5~2 seconds from turn off the light to next trun on  and  

lamp 10% brightness. (Figure 7)

Note: For cycle of step dimming, wait until the lamp is in brightness. 

For failure of step dimming, turn off the lamp and turn on after 3 second.

 

For Step Dimming

,

 For 0-10V Dimming

The driver PUR (D+) to the (PUR),and the 

driver GRY(D-)to the dimmer-(GRY)

Connect the wires with terminal cap as shown in wiring 

diagram (Figure 6).
Incoming insulated dimming conductors shall have 

voltage rated at least equal to the branch voltage.

  

Compatible with 0-10V dimmer

Figure1

Figure2

Figure3

Figure4

Figure5

WIRING DIAGRAM

0-10V

Dimmer

D +

D -

PURPLE

GREY

L
N
G

PURPLE

GREY

RED         BLACK

BLACK
WHITE
GROUND

LED 

PANEL

Dimming

Driver

Figure6

Step Dimming

One Cycle

Note

After

 

3s

 

turn

 

on

 

lamp to

 

100

brightness

.

Turn Off 

Lamp

Turn Off 

Lamp

Turn Off

Lamp

Turn On 

Lamp

10

brightness

Turn On 

Lamp

50

brightness

Turn On 

Lamp

100

brightness

After 0.5S

At

 

0

.

5

-

2s

At

 

0

.

5

-

2s

After 0.5S

After 0.5S

Figure7

To  r igh t po s itio n

It is  the right pos ition whic h is  the 

longer hooks  of the firs t groove.

7-2

1

2

3

4

R ight pos ition

FS SERIES

Surface Mounted Kit 

 

Installation

FS SERIES

Surface Mounted Kit 

 

Installation

S tep2: 

Turn off power. Insert the L,N wires

of the J-box into the male connector.

2

S tep6:

Plug the female connector of the 

luminaire into the male connector of the AC 

input wire.The Ground connects to Green 

wire.Dimming wires connect according to 

the same wire color.

6

S tep4:

Alight the 2 longer hooks on the metal plate with 

the longer hole on the luminaire(Look at the metal palte 

and the luminaire with the 'STEP 1' mark). Slightly move 

the luminaire forward and make sure the hooks is in 

right position.

4

S tep1:

 Remove the surface mounted kit 

from the luminaire.

1

S tep5: 

Fix the metal string on the hook.

(Fig.2)

5

S tep3:

Align the holes on the surface mounted kit with

the hole on the J-box Tighten 2#8-32 screws, rotate

the plate to your right position and lots of KA3.5*20mm

screws into the ceiling and make the kit flush with

the ceiling.

3

Step8:

Push the luminaire on the ceiling. Make

sure the 4 hooks are inside the luminaire and 

push forward the luminaire until you hear a 

clicking sound.

8-1

S tep7:

Put the wire into the J-box.

7-1

8-2

2

RECESSED INST

ALLA TION

FS SERIES

FS SERIES

 INST ALLA TION

Please read this entire manual to fully understand and safely use this product. 
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.

NOTE

Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.

UNP ACKING

1

2

3

Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.

READ  ALL  INSTRUCTIONS BEFORE INST

ALLA TION

1
2

3

4

5

6

7

8

Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in 

with relevant local codes.

accordance 

Risk of electric shock. Ensure that main power source is off when wiring or soldering the 

of the product.

sections 

Before installing this fixture or doing any maintenance, make sure to turn off the power 

the circuit breaker or fuse box.

supply at 

Check to make sure that all fixture connections have been properly made and the fixture 

grounded to avoid potential electrical shocks. 

is 

Do 

in water.

not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or 

This 

conditions to ensure safety to human body.

panel lights are normally set to work at extra low voltage below DC42V and constant current 

OPTIONAL

FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**

Suitable for Damp location

. Access above ceiling required. Suitable for suspended ceilings

IMPORT ANT SAFETYINFORMA

TION

CAUTION: Risk of Electric Shock

!

Accessory:

LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )

page 2

page 1

page 4

page 3

RECESSED INST

ALLA TION

Step3: 

Turn off power,remove the ceiling panel. Then place 

the panel in to the T-bar,ensure he panel is attached to the 

ceiling.(Figure3)

Step4:

connect conduit to J-box with proper connector(s).

Remove appropriate round knock-out(s) and 

Step5:

tightly.the line connect to the connector with the black

mark, the natural connect to another,the ground connect

to the green wire.(Figure4)

Put a connector to the end of AC input wire and               

  

Step1: 

Remove the surface mounted kit 

 

from the luminaire.

                                                                   

Step2: 

Same to 4 hang buckles.(Figure 2)

Bend hang buckle by 90° making it vertical to

the rear cover of panel light. 

Step7:

Push all wires back into the junction box,Close J-BOX for cap  (Figure 5).

 

please use switch to dim and don’t need to connect the dimming

wire. Dimming step: 

Fristly

, Turn on to 100% brightness

Secondly

,It takes about 0.5~2 seconds from turn off the light to 

next trun on and  lamp is in 50% brightness, 

At last 

,It takes 

about 0.5~2 seconds from turn off the light to next trun on  and  

lamp 10% brightness. (Figure 7)

Note: For cycle of step dimming, wait until the lamp is in brightness. 

For failure of step dimming, turn off the lamp and turn on after 3 second.

 

For Step Dimming

,

 For 0-10V Dimming

The driver PUR (D+) to the (PUR),and the 

driver GRY(D-)to the dimmer-(GRY)

Connect the wires with terminal cap as shown in wiring 

diagram (Figure 6).
Incoming insulated dimming conductors shall have 

voltage rated at least equal to the branch voltage.

  

Compatible with 0-10V dimmer

Figure1

Figure2

Figure3

Figure4

Figure5

WIRING DIAGRAM

0-10V

Dimmer

D +

D -

PURPLE

GREY

L
N
G

PURPLE

GREY

RED         BLACK

BLACK
WHITE
GROUND

LED 

PANEL

Dimming

Driver

Figure6

Step Dimming

One Cycle

Note

After

 

3s

 

turn

 

on

 

lamp to

 

100

brightness

.

Turn Off 

Lamp

Turn Off 

Lamp

Turn Off

Lamp

Turn On 

Lamp

10

brightness

Turn On 

Lamp

50

brightness

Turn On 

Lamp

100

brightness

After 0.5S

At

 

0

.

5

-

2s

At

 

0

.

5

-

2s

After 0.5S

After 0.5S

Figure7

To  r igh t po s itio n

It is  the right pos ition whic h is  the 

longer hooks  of the firs t groove.

7-2

1

2

3

4

R ight pos ition

FS SERIES

Surface Mounted Kit 

 

Installation

FS SERIES

Surface Mounted Kit 

 

Installation

S tep2: 

Turn off power. Insert the L,N wires

of the J-box into the male connector.

2

S tep6:

Plug the female connector of the 

luminaire into the male connector of the AC 

input wire.The Ground connects to Green 

wire.Dimming wires connect according to 

the same wire color.

6

S tep4:

Alight the 2 longer hooks on the metal plate with 

the longer hole on the luminaire(Look at the metal palte 

and the luminaire with the 'STEP 1' mark). Slightly move 

the luminaire forward and make sure the hooks is in 

right position.

4

S tep1:

 Remove the surface mounted kit 

from the luminaire.

1

S tep5: 

Fix the metal string on the hook.

(Fig.2)

5

S tep3:

Align the holes on the surface mounted kit with

the hole on the J-box Tighten 2#8-32 screws, rotate

the plate to your right position and lots of KA3.5*20mm

screws into the ceiling and make the kit flush with

the ceiling.

3

Step8:

Push the luminaire on the ceiling. Make

sure the 4 hooks are inside the luminaire and 

push forward the luminaire until you hear a 

clicking sound.

8-1

S tep7:

Put the wire into the J-box.

7-1

8-2

2

RECESSED INST

ALLA TION

FS SERIES

FS SERIES

 INST ALLA TION

Please read this entire manual to fully understand and safely use this product. 
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.

NOTE

Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.

UNP ACKING

1

2

3

Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.

READ  ALL  INSTRUCTIONS BEFORE INST

ALLA TION

1
2

3

4

5

6

7

8

Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in 

with relevant local codes.

accordance 

Risk of electric shock. Ensure that main power source is off when wiring or soldering the 

of the product.

sections 

Before installing this fixture or doing any maintenance, make sure to turn off the power 

the circuit breaker or fuse box.

supply at 

Check to make sure that all fixture connections have been properly made and the fixture 

grounded to avoid potential electrical shocks. 

is 

Do 

in water.

not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or 

This 

conditions to ensure safety to human body.

panel lights are normally set to work at extra low voltage below DC42V and constant current 

OPTIONAL

FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**

Suitable for Damp location

. Access above ceiling required. Suitable for suspended ceilings

IMPORT ANT SAFETYINFORMA

TION

CAUTION: Risk of Electric Shock

!

Accessory:

LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )

page 2

page 1

page 4

page 3

RECESSED INST

ALLA TION

Step3: 

Turn off power,remove the ceiling panel. Then place 

the panel in to the T-bar,ensure he panel is attached to the 

ceiling.(Figure3)

Step4:

connect conduit to J-box with proper connector(s).

Remove appropriate round knock-out(s) and 

Step5:

tightly.the line connect to the connector with the black

mark, the natural connect to another,the ground connect

to the green wire.(Figure4)

Put a connector to the end of AC input wire and               

  

Step1: 

Remove the surface mounted kit 

 

from the luminaire.

                                                                   

Step2: 

Same to 4 hang buckles.(Figure 2)

Bend hang buckle by 90° making it vertical to

the rear cover of panel light. 

Step7:

Push all wires back into the junction box,Close J-BOX for cap  (Figure 5).

 

please use switch to dim and don’t need to connect the dimming

wire. Dimming step: 

Fristly

, Turn on to 100% brightness

Secondly

,It takes about 0.5~2 seconds from turn off the light to 

next trun on and  lamp is in 50% brightness, 

At last 

,It takes 

about 0.5~2 seconds from turn off the light to next trun on  and  

lamp 10% brightness. (Figure 7)

Note: For cycle of step dimming, wait until the lamp is in brightness. 

For failure of step dimming, turn off the lamp and turn on after 3 second.

 

For Step Dimming

,

 For 0-10V Dimming

The driver PUR (D+) to the (PUR),and the 

driver GRY(D-)to the dimmer-(GRY)

Connect the wires with terminal cap as shown in wiring 

diagram (Figure 6).
Incoming insulated dimming conductors shall have 

voltage rated at least equal to the branch voltage.

  

Compatible with 0-10V dimmer

Figure1

Figure2

Figure3

Figure4

Figure5

WIRING DIAGRAM

0-10V

Dimmer

D +

D -

PURPLE

GREY

L
N
G

PURPLE

GREY

RED         BLACK

BLACK
WHITE
GROUND

LED 

PANEL

Dimming

Driver

Figure6

Step Dimming

One Cycle

Note

After

 

3s

 

turn

 

on

 

lamp to

 

100

brightness

.

Turn Off 

Lamp

Turn Off 

Lamp

Turn Off

Lamp

Turn On 

Lamp

10

brightness

Turn On 

Lamp

50

brightness

Turn On 

Lamp

100

brightness

After 0.5S

At

 

0

.

5

-

2s

At

 

0

.

5

-

2s

After 0.5S

After 0.5S

Figure7

To  r igh t po s itio n

It is  the right pos ition whic h is  the 

longer hooks  of the firs t groove.

7-2

1

2

3

4

R ight pos ition

FS SERIES

Surface Mounted Kit 

 

Installation

FS SERIES

Surface Mounted Kit 

 

Installation

S tep2: 

Turn off power. Insert the L,N wires

of the J-box into the male connector.

2

S tep6:

Plug the female connector of the 

luminaire into the male connector of the AC 

input wire.The Ground connects to Green 

wire.Dimming wires connect according to 

the same wire color.

6

S tep4:

Alight the 2 longer hooks on the metal plate with 

the longer hole on the luminaire(Look at the metal palte 

and the luminaire with the 'STEP 1' mark). Slightly move 

the luminaire forward and make sure the hooks is in 

right position.

4

S tep1:

 Remove the surface mounted kit 

from the luminaire.

1

S tep5: 

Fix the metal string on the hook.

(Fig.2)

5

S tep3:

Align the holes on the surface mounted kit with

the hole on the J-box Tighten 2#8-32 screws, rotate

the plate to your right position and lots of KA3.5*20mm

screws into the ceiling and make the kit flush with

the ceiling.

3

Step8:

Push the luminaire on the ceiling. Make

sure the 4 hooks are inside the luminaire and 

push forward the luminaire until you hear a 

clicking sound.

8-1

S tep7:

Put the wire into the J-box.

7-1

8-2

2

RECESSED INST

ALLA TION

FS SERIES

FS SERIES

 INST ALLA TION

Please read this entire manual to fully understand and safely use this product. 
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.

NOTE

Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.

UNP ACKING

1

2

3

Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.

READ  ALL  INSTRUCTIONS BEFORE INST

ALLA TION

1
2

3

4

5

6

7

8

Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in 

with relevant local codes.

accordance 

Risk of electric shock. Ensure that main power source is off when wiring or soldering the 

of the product.

sections 

Before installing this fixture or doing any maintenance, make sure to turn off the power 

the circuit breaker or fuse box.

supply at 

Check to make sure that all fixture connections have been properly made and the fixture 

grounded to avoid potential electrical shocks. 

is 

Do 

in water.

not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or 

This 

conditions to ensure safety to human body.

panel lights are normally set to work at extra low voltage below DC42V and constant current 

OPTIONAL

FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**

Suitable for Damp location

. Access above ceiling required. Suitable for suspended ceilings

IMPORT ANT SAFETYINFORMA

TION

CAUTION: Risk of Electric Shock

!

Accessory:

LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )

page 2

page 1

page 4

page 3

RECESSED INST

ALLA TION

Step3: 

Turn off power,remove the ceiling panel. Then place 

the panel in to the T-bar,ensure he panel is attached to the 

ceiling.(Figure3)

Step4:

connect conduit to J-box with proper connector(s).

Remove appropriate round knock-out(s) and 

Step5:

tightly.the line connect to the connector with the black

mark, the natural connect to another,the ground connect

to the green wire.(Figure4)

Put a connector to the end of AC input wire and               

  

Step1: 

Remove the surface mounted kit 

 

from the luminaire.

                                                                   

Step2: 

Same to 4 hang buckles.(Figure 2)

Bend hang buckle by 90° making it vertical to

the rear cover of panel light. 

Step7:

Push all wires back into the junction box,Close J-BOX for cap  (Figure 5).

 

please use switch to dim and don’t need to connect the dimming

wire. Dimming step: 

Fristly

, Turn on to 100% brightness

Secondly

,It takes about 0.5~2 seconds from turn off the light to 

next trun on and  lamp is in 50% brightness, 

At last 

,It takes 

about 0.5~2 seconds from turn off the light to next trun on  and  

lamp 10% brightness. (Figure 7)

Note: For cycle of step dimming, wait until the lamp is in brightness. 

For failure of step dimming, turn off the lamp and turn on after 3 second.

 

For Step Dimming

,

 For 0-10V Dimming

The driver PUR (D+) to the (PUR),and the 

driver GRY(D-)to the dimmer-(GRY)

Connect the wires with terminal cap as shown in wiring 

diagram (Figure 6).
Incoming insulated dimming conductors shall have 

voltage rated at least equal to the branch voltage.

  

Compatible with 0-10V dimmer

Figure1

Figure2

Figure3

Figure4

Figure5

WIRING DIAGRAM

0-10V

Dimmer

D +

D -

PURPLE

GREY

L
N
G

PURPLE

GREY

RED         BLACK

BLACK
WHITE
GROUND

LED 

PANEL

Dimming

Driver

Figure6

Step Dimming

One Cycle

Note

After

 

3s

 

turn

 

on

 

lamp to

 

100

brightness

.

Turn Off 

Lamp

Turn Off 

Lamp

Turn Off

Lamp

Turn On 

Lamp

10

brightness

Turn On 

Lamp

50

brightness

Turn On 

Lamp

100

brightness

After 0.5S

At

 

0

.

5

-

2s

At

 

0

.

5

-

2s

After 0.5S

After 0.5S

Figure7

To  r igh t po s itio n

It is  the right pos ition whic h is  the 

longer hooks  of the firs t groove.

7-2

1

2

3

4

R ight pos ition

FS SERIES

Surface Mounted Kit 

 

Installation

FS SERIES

Surface Mounted Kit 

 

Installation

S tep2: 

Turn off power. Insert the L,N wires

of the J-box into the male connector.

2

S tep6:

Plug the female connector of the 

luminaire into the male connector of the AC 

input wire.The Ground connects to Green 

wire.Dimming wires connect according to 

the same wire color.

6

S tep4:

Alight the 2 longer hooks on the metal plate with 

the longer hole on the luminaire(Look at the metal palte 

and the luminaire with the 'STEP 1' mark). Slightly move 

the luminaire forward and make sure the hooks is in 

right position.

4

S tep1:

 Remove the surface mounted kit 

from the luminaire.

1

S tep5: 

Fix the metal string on the hook.

(Fig.2)

5

S tep3:

Align the holes on the surface mounted kit with

the hole on the J-box Tighten 2#8-32 screws, rotate

the plate to your right position and lots of KA3.5*20mm

screws into the ceiling and make the kit flush with

the ceiling.

3

Step8:

Push the luminaire on the ceiling. Make

sure the 4 hooks are inside the luminaire and 

push forward the luminaire until you hear a 

clicking sound.

8-1

S tep7:

Put the wire into the J-box.

7-1

8-2

2

RECESSED INST

ALLA TION

FS SERIES

FS SERIES

 INST ALLA TION

Please read this entire manual to fully understand and safely use this product. 
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.

NOTE

Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.

UNP ACKING

1

2

3

Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.

READ  ALL  INSTRUCTIONS BEFORE INST

ALLA TION

1
2

3

4

5

6

7

8

Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in 

with relevant local codes.

accordance 

Risk of electric shock. Ensure that main power source is off when wiring or soldering the 

of the product.

sections 

Before installing this fixture or doing any maintenance, make sure to turn off the power 

the circuit breaker or fuse box.

supply at 

Check to make sure that all fixture connections have been properly made and the fixture 

grounded to avoid potential electrical shocks. 

is 

Do 

in water.

not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or 

This 

conditions to ensure safety to human body.

panel lights are normally set to work at extra low voltage below DC42V and constant current 

OPTIONAL

FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**

Suitable for Damp location

. Access above ceiling required. Suitable for suspended ceilings

IMPORT ANT SAFETYINFORMA

TION

CAUTION: Risk of Electric Shock

!

Accessory:

LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )

page 2

page 1

page 4

page 3

RECESSED INST

ALLA TION

Step3: 

Turn off power,remove the ceiling panel. Then place 

the panel in to the T-bar,ensure he panel is attached to the 

ceiling.(Figure3)

Step4:

connect conduit to J-box with proper connector(s).

Remove appropriate round knock-out(s) and 

Step5:

tightly.the line connect to the connector with the black

mark, the natural connect to another,the ground connect

to the green wire.(Figure4)

Put a connector to the end of AC input wire and               

  

Step1: 

Remove the surface mounted kit 

 

from the luminaire.

                                                                   

Step2: 

Same to 4 hang buckles.(Figure 2)

Bend hang buckle by 90° making it vertical to

the rear cover of panel light. 

Step7:

Push all wires back into the junction box,Close J-BOX for cap  (Figure 5).

 

please use switch to dim and don’t need to connect the dimming

wire. Dimming step: 

Fristly

, Turn on to 100% brightness

Secondly

,It takes about 0.5~2 seconds from turn off the light to 

next trun on and  lamp is in 50% brightness, 

At last 

,It takes 

about 0.5~2 seconds from turn off the light to next trun on  and  

lamp 10% brightness. (Figure 7)

Note: For cycle of step dimming, wait until the lamp is in brightness. 

For failure of step dimming, turn off the lamp and turn on after 3 second.

 

For Step Dimming

,

 For 0-10V Dimming

The driver PUR (D+) to the (PUR),and the 

driver GRY(D-)to the dimmer-(GRY)

Connect the wires with terminal cap as shown in wiring 

diagram (Figure 6).
Incoming insulated dimming conductors shall have 

voltage rated at least equal to the branch voltage.

  

Compatible with 0-10V dimmer

Figure1

Figure2

Figure3

Figure4

Figure5

WIRING DIAGRAM

0-10V

Dimmer

D +

D -

PURPLE

GREY

L
N
G

PURPLE

GREY

RED         BLACK

BLACK
WHITE
GROUND

LED 

PANEL

Dimming

Driver

Figure6

Step Dimming

One Cycle

Note

After

 

3s

 

turn

 

on

 

lamp to

 

100

brightness

.

Turn Off 

Lamp

Turn Off 

Lamp

Turn Off

Lamp

Turn On 

Lamp

10

brightness

Turn On 

Lamp

50

brightness

Turn On 

Lamp

100

brightness

After 0.5S

At

 

0

.

5

-

2s

At

 

0

.

5

-

2s

After 0.5S

After 0.5S

Figure7

To  r igh t po s itio n

It is  the right pos ition whic h is  the 

longer hooks  of the firs t groove.

7-2

1

2

3

4

R ight pos ition

1. Remove Surface Mounting Kit and panel 

from packaging.
2. Turn off  power and run supply wiring 

through J-box.  Insert supply line and neutral 

power wires into corresponding locations on 

orange quick disconnect. Line is labeled in 

black, neutral is white. (Fig. 2)

3. Temporarily attach Surface Mounting Kit to 

J-box and align to the desired orientation. Mark 

screw holes and drill pilot holes then remove 

Surface Mounting Kit.  Insert screw anchors into 

mounting surface at marks.  Reinstall Surface 

Mounting Kit to junction box and install screws to 

screw anchors. (Fig. 3)

4. Screw Steel Cable Service Loop to light 

panel (see Fig.5). Align the longer hooks 

labeled “Step 1” on the Surface Mounting 

Bracket to the larger slots along the edge of 

the panel backing labeled “Step 1” and slide to 

the fi rst notch. (Fig. 4)

5. Attach the Steel Cable Service Loop from the 

panel to one of the Surface Mount Kit hooks. 

Loop holds the panel while wiring. (Fig. 5)

6. Connect the green ground wire to supply 

ground wire. Connect the two orange quick 

disconnects together. Connect the 0~10V 

dimming wires according to the Wiring 

Diagram with wire nuts. (Fig. 6)

7. Tuck wiring into junction box being sure not to 

pinch wires. (Fig. 7-1 & 7-2)

8. Lift panel onto remaining hooks on Surface 

Mounting Bracket while aligning to remaining 

slots on panel. Slide panel the same direction 

as step 4 until the panel locks into the second 

notch. (Fig. 8-1 & 8-2)

Screw

Screw

• This product should be installed by a fully 

certifi ed electrician in accordance with local 

building and electrical codes

• 

Due to risk of electric shock, ensure that the 

main power source and circuit breakers are 

switched off  before performing any installation 

or wiring procedures

• 

Do not install insulation within 2 in / 51mm of 

any part of the panel light fi xture.

Safety Information

CAUTION! Risk Of Electric Shock

Turn off  all power prior to installation 

by switching off  circuit breaker or 

removing fuse at fuse box.

Reviews: