-3-
2. CAUTIONS IN INSTALLATION
1.
Fix the pipeline to keep it from vibrating or moving.
2.
Make sure that the pipe connections are sealed and air is not entering the system.
3.
If the filter must be installed outdoors, it is essential to provide adequate covering.
4.
Choose heat resistant pipes if the temperature of the solution is higher than 60
℃
.
5.
Before connecting tubing to the pump attachments, the tubes should be washed to
remove any extraneous matter there may be such as welding pellets, cut-off from
gaskets, etc.
6.
Set a foot-valve at the end of inlet pipe. Secure the inlet pipe to keep it from
moving or bending if using soft pipes. (We recommend stiff pipes inside the tank.)
7.
Place the machine in an upright position and on a sturdy resting place.
8.
When the pump inlet and outlet are lower than the liquid level of the tank, install
valves on the inlet and outlet pipe to prevent siphoning.
9.
Please make sure that the inlet connecting flange is equal in diameter with the
inlet flange, and the outlet connecting flange is the same size as the outlet flange.
Please also make sure that all the nuts and bolts are adequately tightened,
including the wing nut on the top cover.
Warning:
Under-tightening and over-tightening may result in flawed
performance and even safety hazards. Under-tightening may lead to the
development of leaks, while over-tightening may strip or break the bolt. Please
have someone experienced in the installation of this type of equipment to set up
the system.