6. Charging the Battery Packs

•  Remove Makita batteries from fan.
•  Insert in Makita Charger. Use only Makita XGT

®

 brand battery chargers.

•  When the battery pack temperature is outside the charging range (40-105ºF or 5-40ºC), the red 

light on the charger will flash and the battery will not charge.

•  Once the battery pack is within the acceptable temperature range, normal charging will take place.
•  Using the Makita Rapid Optimum Charger, a 4.0 Amp hour battery will recharge in 45 minutes and 

an 5.0 Amp hour battery will recharge in 50 minutes.

•  Other Makita chargers, including units that work with vehicle DC power, may take longer to fully 

charge the batteries.

CAUTION:

•  Do not store battery packs or 

chargers above 120°F (50°C) or 

in direct sunlight. 

•  Never use charger or batteries 

in explosive atmospheres. 

•  Never attempt to open the 

battery pack. If cracked or 

damaged, return it to a service 

center for recycling. 

•  Do not splash or immerse 

charger in water or other liquids.

Maintenance should only be performed by experienced and trained personnel.
If you have any questions, contact Super Vac before attempting any maintenance at [email protected] or 1-800-525-5224.

7. Maintenance and Repair

Daily/After Each Use:

•  Charge batteries completely

•  Check that Guards are undamaged and 

effectively prevent objects from contacting 

the blade

•  Wheels and feet are in place and tight

•  Tilt Mechanism works properly

•  If tilt adjust is too loose, tighten knurled 

nut on the Tilt Mechanism.

•  For larger adjustments, tighten nut with 

9/16” (14mm) wrench. 

 

 

 

Weekly/Monthly/Quarterly:

•  Calibrate Battery

•  Fully charging, then fully discharging, 

and fully charging once again before 

storage

•  Replace battery (-ies) if battery shows 

signs of damage from dropping or 

excessive heat

•  Check for loose fasteners

•  Check condition of the power cord (if 

purchased with Shore Power) (14mm) 

wrench. 

 

 

Yearly:

•  Battery Condition

•  Check runtime in low wind and average 

temperature conditions

•  If runtime is below 75% of advertised 

runtime, replacing batteries is 

recommended

•  Excessive vibration

•  Blade imbalance due to accumulation of 

dirt on blade

•  Check Blade interference

•  Remove front guard and rotate manually 

to check for interference

To-Do Checklists:

Summary of Contents for V18-BK

Page 1: ...READ THIS FIRST VENTILATOR USER GUIDE MODEL V18 BK...

Page 2: ......

Page 3: ...to read this manual before operating the ventilator Save this guide for future reference CONTENTS 1 BREAKAGE OR DAMAGE DURING SHIPMENT 2 2 GENERAL DESCRIPTION AND SPECIFICATIONS 3 3 PRODUCT SAFETY PRE...

Page 4: ...f we filed claim here it would be sent to your local freight agent for verification and investigation This time can be saved by your filing the claim directly Every consignee is on the ground floor an...

Page 5: ...tor Never operate ventilator while fatigued Do not disassemble or modify the ventilator in any way Doing so may lead to mechanical failure or personal injury Do not wear loose clothing that could beco...

Page 6: ...missing guards before operating ventilator Never store or carry the battery pack so that metal objects can contact exposed battery terminals Transporting batteries can possibly cause fires if the batt...

Page 7: ...is feature is to protect the batteries from small parasitic draws Turn speed control clockwise until desired speed is reached Power button will indicate approximate power left It is normal for colors...

Page 8: ...Maintenance should only be performed by experienced and trained personnel If you have any questions contact Super Vac before attempting any maintenance at info supervac com or 1 800 525 5224 7 Mainte...

Page 9: ...ent of any type or cause are not covered by this warranty All equipment manufactured by us is pre run and tested before leaving our plant and is shipped in good working order and condition We therefor...

Page 10: ...er Revised 3 2022 9 Contact For parts or service information contact Super Vacuum Manufacturing Company Inc 3842 Redman Dr Fort Collins CO 80524 Phone 800 525 5224 970 297 7100 Fax 970 297 7099 Email...

Page 11: ...POSITIVE PRESSURE VENTILATOR 9 V18 BK PPV User Revised 3 2022 10 Parts List V18 BX V18 BX MAKITA_BATTERY_MOUNT_SPACER MAKITA_BATTERY_MOUNT_SPACER...

Page 12: ...POSITIVE PRESSURE VENTILATOR 10 V18 BK PPV User Revised 3 2022 11 Exploded View...

Reviews: