background image

User Guide

10

12. Parts List

1

012-10271

1

GUARD 24” STD. FRONT-FINISHED

2

034-12941

16

10-24 X 1/2" PHIL PH MS BLACK SS

3

032-10713

16

10-24 NYLOK SELF LOCK NUT ZINC

4

032-10759

1

1/4 – 20 LEFT HAND SCREW ZINC

5

032-10755

1

1/4” FENDER WASHER USS ZINC

6

032-10761

2

5/16 – 18 x 1/2” ALLEN SET SCREW

7

003-10049

1

BLADE 24” FOUR BLADE FINISHED

8

008-10193

1

3/16” X 1 3/8” MOTOR SHAFT KEY

9

005-10139

1

HUBBELL #SHC1024 CONNECTOR

10

022-10501

1

MOTOR P244S 1 1/2HP TEAO 115/230VAC

11

032-10768

4

5/16 – 18 X 3/4” HEX CS ZINC

12

032-10790

4

5/16-18 NYLOK HEX NUT ZINC

13

024-10527

4

FEET #1409-W RECTANGULAR

14

032-10698

8

8-32 X 1/2” PHIL PH MS ZINC

15

032-10695

8

8-32 HEX NUT ZINC

16

018-10389

1

HOUSING 24” STEEL PAINTED

17

005-10134

1

HEYCO 8P-2 GROMMET

18

005-14099

1

CORD 12-3 SOW X 10’ MOLDED #93261-1

19

012-10272

1

GUARD 24” STD. REAR FINISHED

20

005-10145

1

CARLING SWITCH ON-OFF 2X633

21

020-10476

1

CORD HOLDER PAINTED

22

035-11114

4

RIVET #4-6 SSD

23

005-10134

1

HEYCO 8P-2 GROMMET

24

056-12384

1

PLUG #MP-500

25

025-10559

1

DECAL – ORANGE CAUTION 120V

26

025-10548

1

DECAL – CAUTION GUARDS REMOVED

27

025-13396

1

DECAL – P244S SERIAL NUMBER GRAY

28

025-13395

1

DECAL –P244S SAFETY YELLOW

29

025-10548

1

DECAL – EXHAUST ARROW

008-15094

1

VENTILATOR USER GUIDE P244S

Summary of Contents for P244S

Page 1: ...P N 008 15094 VENTILATOR USER GUIDE MODEL P244S...

Page 2: ...r Save this guide for future reference CONTENTS 1 BREAKAGE OR DAMAGE DURING SHIPMENT 2 2 GENERAL DESCRIPTION AND SPECIFICATIONS 3 3 PRODUCT SAFETY PRECAUTIONS 4 4 BEFORE OPERATING VENTILATOR 4 5 OPERA...

Page 3: ...would be sent to your local freight agent for verification and investigation This time can be saved by your filing the claim directly Every consignee is on the ground floor and in contact with the loc...

Page 4: ...signed for high powered air movement Super Vac s patented propeller produces a greater intake of air and eliminates turbulence at the tips The high velocity screw action sweeps air back over the motor...

Page 5: ...o not place or operate ventilator on unsteady tables slanted surfaces or other unstable surfaces Never handle energized power cords with wet hands Never let extension cords or plug connection lay in w...

Page 6: ...le 6 Maintenance and Repair Maintenance should only be performed by experienced and trained personnel Be sure the ventilator is disconnected from the power source before performing any maintenance or...

Page 7: ...r supply Common causes of motor overheating Power generator not providing constant voltage Ventilators are equipped with AC motors designed to operate on power that falls between 3 of design specifica...

Page 8: ...age requirements When conditions require the use of reeled cable unreel all cable and place on the ground in very loose overlapping non uniform coils Units1 WATTS2 Minimum Wire Gauge Maximum Cable Len...

Page 9: ...plant and is shipped in good working order and condition We therefore extend to the original purchasers the following Limited Warranty for the period of five years from the original date of purchase...

Page 10: ...e PS Series doc REV 08 13 03 11 Contact Information For parts or service information contact Super Vacuum Manufacturing Company Inc 3842 Redman Dr Fort Collins CO 80524 Phone 1 800 525 5224 970 297 71...

Page 11: ...5 16 18 NYLOK HEX NUT ZINC 13 024 10527 4 FEET 1409 W RECTANGULAR 14 032 10698 8 8 32 X 1 2 PHIL PH MS ZINC 15 032 10695 8 8 32 HEX NUT ZINC 16 018 10389 1 HOUSING 24 STEEL PAINTED 17 005 10134 1 HEY...

Page 12: ...ELECTRIC VENTILATOR 11 P244S_VentilatorUserGuide PS Series doc REV 08 13 03 CAUTION CONNECTED FOR 120V 60CY AC 13 Exploded View...

Reviews: