BRAKE COOLING FAN

724BCX User Guide

Revised 2-2015

4. Before Operating Ventilator

•  Always operate this ventilator from a proper AC power source supplied through a ground fault interrupter receptacle. Test

•  receptacle for ground fault before plugging in the ventilator power cord.

•  A complete inspection of the ventilator should be made prior to operation.

•  Never use power cords with frayed, cut, or brittle insulation.

•  Inspect power cord plug for sound connections to the ground fault interrupter circuit.

•  Check all threaded fasteners for proper tightness.

•  Inspect inlet and outlet guards for damage or missing pieces. Replace damaged or missing guards before operating ventilator.

5. Operation

Check ventilator inlet and outlet guards for obstructions. Check and remove from immediate surrounding area any objects that could be 

drawn into the ventilator intake.

Place ventilator in desired location before connecting to power supply.

Use caution not to direct toxic fumes into confined spaces with the ventilator.

Insert power cord plug into 115/230 VAC power receptacle to begin ventilation.

To stop ventilation turn motor switch to off position, remove power cord plug from AC power receptacle.

Summary of Contents for 724BCX

Page 1: ...READ THIS FIRST VENTILATOR USER GUIDE MODEL 724BCX...

Page 2: ......

Page 3: ...d this manual before operating the fan Save this guide for future reference CONTENTS 1 BREAKAGE OR DAMAGE DURING SHIPMENT 2 GENERAL DESCRIPTION AND SPECIFICATIONS 3 PRODUCT SAFETY PRECAUTIONS 4 BEFORE...

Page 4: ...filed claim here it would be sent to your local freight agent for verification and investigation This time can be saved by your filing the claim directly Every consignee is on the ground floor and in...

Page 5: ...ay Doing so may lead to mechanical failure or personal injury Do not wear loose clothing that could become entangled in the operating ventilator Do not operate ventilator without proper inlet or outle...

Page 6: ...circuit Check all threaded fasteners for proper tightness Inspect inlet and outlet guards for damage or missing pieces Replace damaged or missing guards before operating ventilator 5 Operation Check v...

Page 7: ...nect spark plug wire from spark plug and keep it away from spark plug The ventilator blade should be specially checked for build up of material or dirt which may cause an imbalance Excessive imbalance...

Page 8: ...o generator Do not exceed generator capacity Using accessory ducting of too small a diameter or excessive length Incorrect amperage circuit breaker for circuit load Using reeled or coiled extension co...

Page 9: ...n a voltage drop within the motor instigating a thermal overload condition Power supply must handle wattage requirements When conditions require the use of reeled cable unreel all cable and place on t...

Page 10: ...g our plant and is shipped in good working order and condition We therefore extend to the original purchasers the following Limited Warranty for the period of five years from the original date of purc...

Page 11: ...2 2015 10 Contact Information For parts or service information contact Super Vacuum Manufacturing Company Inc 3842 Redman Dr Fort Collins CO 80524 Phone 800 525 5224 970 297 7100 Fax 970 297 7099 Emai...

Page 12: ...ENTER 16 032 11129 2 3 8 FLAT WASHER USS ZINC 17 032 11133 2 3 8 16 NYLOK HEX NUT ZINC 18 008 14622 1 VENTILATOR BRAKE MOUNT 1 19 008 14631 1 724 BRAKE BAR FINISHED 20 032 10725 3 1 4 20 X 5 8 PHIL RH...

Page 13: ...BRAKE COOLING FAN 11 724BCX User Guide Revised 2 2015 12 Exploded View...

Page 14: ......

Reviews: