1.4
OPERATING RESTRICTIONS
CAUTION:
Single wall heat exchangers must use a heat transfer medium such as water or other non-
toxic fluids having a toxicity rating of Class 1, as listed in Clinical Toxicology of Commercial Products
(current edition)
.
The pressure of the heat transfer medium must be limited to a maximum of 150psi by an
approved pressure relief valve.
Maximum working pressure of the tank is 150psi.
1.5
WATER QUALITY
Always use good quality water to prolong the life of the tank. Water that is safe to drink and even city
water is not necessarily good quality water for the tank. The use of filters can prevent corrosion and
reduce sediments inside the tank. Water hardness, pH, and chlorides must be controlled to normal levels.
•
PH levels must be between 6.0 and 8.0 and dissolved chlorides below 100ppm.
If you are unsure, use a water softening system or consult a qualified water treatment expert.
NOTE: All improper use as detailed above could void the warranty of the tank.
Summary of Contents for EPP SERIES
Page 7: ...EPP SERIES INDIRECT WATER HEATERS Installation and Service Manual 7...
Page 9: ...EPP SERIES INDIRECT WATER HEATERS Installation and Service Manual 9 Multiple Water Heaters...
Page 13: ...EPP SERIES INDIRECT WATER HEATERS Installation and Service Manual 13...
Page 14: ...EPP SERIES INDIRECT WATER HEATERS Installation and Service Manual 14...
Page 15: ...EPP SERIES INDIRECT WATER HEATERS Installation and Service Manual 15...
Page 16: ...EPP SERIES INDIRECT WATER HEATERS Installation and Service Manual 16...
Page 22: ...EPP SERIES INDIRECT WATER HEATERS Installation and Service Manual 22 8 0 NOTES...
Page 23: ...EPP SERIES INDIRECT WATER HEATERS Installation and Service Manual 23...