background image

3

4

Water Connection

Connect a safety valve to the cold water inlet. 

It is recommended to keep the cold water inlet faucet open at all times. 
Note: It is normal if the safety valve drips during heating.

Inlet and outlet connection gauge should be the same.

Inlet water pressure should be under 1kgf/cm². Highly recommended 
to install a pressure decreasing valve if it exceeds 3kgf/cm².

Connect a pressure release pipe to a pressure releasing hole on the 
safety valve to avoid danger caused by pressure-releasing,
Note: Pressure releasing hole should never be blocked.

Power Connection

The power cord is either black or red. Connect green earth cord correctly.
 
Note: The blue dot on the inlet pipe indicates cold water inlet whereas 
the red dot indicates hot water outlet. Make sure the installation is correct.

Installation

Important Reminder

Install as close to the faucet as possible to prevent heat loss in the pipe.

Ensuring the tripod or wall-mounted hook is tight when installing.

Upon completion of installation, turn on the cold water inlet valve until
water is available via the hot water outlet faucet to ensure the unit is
contained with water, and then turn on the power and press the leakage
circuit breaker to ON. (Required only for the first-time use.)  

Installation should be carried out by 

t

echnical personnel

.

Super Guider is not liable for any harm caused by not following the 
instructions in this booklet or safety regulations during installation.

Turn off the power before adjustment

Note

After installation, turn on the cold water valve. When the tank is full of 
water, loosen the screw and take off the panel after hot water is out from
the pipe. Turn on the leakage circuit breaker to prevent the heater pipe 
from failure.

Warranty are excluding any non - complying with the prescribed safety 
requirements and Installation which is not in accordance with the manual 
instructions.

Warranty is excluding the poor water quality e.g. ground water. Water 
purification beforehand could extend the life span of the water heater.

Installation charge will be borne by the user.

★ 

 Indicator light illuminates upon switching on of the 

    power, stays on while heating.

Temperature adjusted button.

 (If overheating prevention device

Reset

Interrupt, THE RED BUTTON should be
pushed first after maintenance, and the 
electricity supply will be recovered.

TEMPERATURE CONTROLLER