background image

LED Flood Light

Important: Read all instructions prior to installation.

WN-FL01-RD01

4400 Earth City Expy, St. Louis, MO 63045          

866-590-3533            superbrightleds.com

Rev Date: V0.1 07/24/2019

5

yr

Specifications

Safety and Notes

Operating Voltage Range

100–277 VAC

Total Power Consumption

18 W

Current Draw

0.15 A@120 VAC

Beam Angle

NEMA 2x2 (20°x20°)

Operating Temperature

-40°–122° F(-40°–50° C)

Environmental Rating

IP65

Dimmable 

No

Model

WN-FL01-RD01

•  Product should be installed and serviced in accordance with 

applicable national, state, and local building and electrical codes.

•  To reduce the risk of electric shock, ensure that the main power 

source and circuit breakers are switched off before performing 

any installation or wiring procedures.

•  Avoid looking directly into lamp when illuminated.

•  Ensure all mounts are securely attached and will support the 

weight of the fixture. Failure to properly support fixture may result 

in damage or injury, for which the manufacturer does not  

assume responsibility.

AFL-50K50-110-U

Wiring Diagram

Line

Neutral

Ground

Black

L

L

N

N

GND

GND

White

Dim (+)

Dim (-)

Purple

+

+

-

-

Gray

Green

User Manual

Installation Instructions (U-bracket/Yoke Mount)

1.  Drill holes for mounting and wiring as needed.

2.  Securely attach light to surface and connect wiring.

3.  Apply power and rotate light head to desired angle.

Drill