Page 1: ... 1 PIT6L MINI INFRARED THERMOMETER with Ambient Temperature USER S MANUAL ...

Page 2: ...er with the functions of laser targeting back light data hold and auto power off 2 Safety Information Please read the following information carefully before using the meter Do not clean the meter using solvents Warning Do not point laser directly at eye or reflective surfaces ...

Page 3: ...fore taking measurements Avoiding EMF electro magnetic fields from arc weld induction furnace etc Do not leave the unit on or near high temperature objects 3 Instrument Description Infrared sensor LCD display Back light button Ambient temperature measurement button Wrist band ...

Page 4: ... 4 Laser targeting aperture Scan button Measurement and laser button C F selection switch Battery cover Tamb 0 95 SCAN ...

Page 5: ... 5 LCD display Measurement indication Low power indication Ambient temperature measurement indication ...

Page 6: ...dication Data hold indication C temperature units F temperature units 4 Specifications Measurement range 4 F to 518 F 20 C to 270 C Accuracy at ambient of 72 F 22 C 2 reading 6 F 3 C Temperature measurement range 32 F to 122 F 0 C to 50 C Resolution 1 F 1 C ...

Page 7: ...ff After 20 sec 5 Operating Instructions 5 1 Point the infra red sensor at the object and press the SCAN button Release the SCAN button and the measured result will hold automatically The meter shuts off after 20 seconds of inactivity To get an accurate measurement result refer to D S ratio Emissivity section ...

Page 8: ...ll appear on LCD Now press the SCAN button the measured ambient temperature will be displayed on the LCD Release the SCAN button the measured result will hold automatically Unit automatically turns off after about 20 seconds of inactivity To return to infra red measurements press the Tamb button again Tamb will disappear from LCD and then follow the steps in section ...

Page 9: ...inless steel the emissivity from surface is low and the measurement accuracy will be affected An effective solution is that using the black adhesive tape to cover the object surface starting the measurement until the adhesive tape s temperature is same as the object Warning Do not point laser directly at eye or indirectly off reflective surfaces 4 ...

Page 10: ...o turn on the backlight Measurement unit C F selection Open the battery cover and take the battery out shift the switch to select the measurement unit 6 D S ratio The thermometer has a visual angle and visual spot size a drawing is shown as follows ...

Page 11: ...1 Make sure that the target is larger than the unit s visual spot size The smaller the target the closer you should be to it The relationship between distance and spot size is 6 1 the drawing as following ...

Page 12: ... 12 8 Replace batteries If the sign appears on the LCD display it indicates that battery should be replaced Remove the battery cover and replace the exhausted batteries with new ones ...

Page 13: ...duct which within the specified warranty term after the date of sale by the Wholesaler is proved to the satisfaction of Sealed Unit Parts Co Inc to have been defective at the time it was sold Said warranty is in effect only when said item is used in accordance with the instructions and recommendations of Sealed Unit Parts Co Inc ...

Page 14: ...is warranty to repair or replace is the only warranty either expressed implied or statutory and is the only warranty being issued herein Sealed Unit Parts Co Inc s liability in connection with its products is expressly limited to the repair or replacement of defective parts All other damages and warranties statutory or otherwise are being expressly excluded ...

Page 15: ...o change this warranty in any manner whatsoever No attempt to repair or promise to repair or improve any part covered by this warranty by any representative of this company shall be effective unless signed by a properly authorized officer of Sealed Unit Parts Co Inc ...

Page 16: ... 16 Sealed Unit Parts Co Inc SUPCO 2230 Landmark Place Allenwood NJ 08720 USA www supco com info supco com ...