CAUTIONS

2

CME-LX100 No.2137-00

LX-100

Make sure that the power supply is off while wiring.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
Take care that if a voltage exceeding the rated range is applied, or if an AC
power supply is directly connected, the sensor may get burnt or damaged.
In case noise generating equipment (switching regulator, inverter mo-
tor, etc.) is used in the vicinity of this product, connect the frame ground
(F.G.) terminal of the equipment to an actual ground.
If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
Do not use during the initial transient time (0.5 sec.) after the power
supply is switched on.
Take care that short-circuit of the load or wrong wiring may burn or damage the sensor.
Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
Take care that the sensor is not directly exposed to fluorescent light
from a rapid-starter lamp or a high frequency light device.
If the surface of the sensing object has a shine,
mount the sensor inclining approx. 10 to 15 degrees
against the sensing object.
Do not touch the lens of the sensor by hand directly. If
the lens becomes dirty, wipe it off with a soft cloth gently.
When the inside lens is steamed up, unscrew the
lens to get rid of the condensation.
For LX-101-

غ

-Z, be sure to use the optional cable with connector.

Extension up to total 100m is possible with 0.3mm

2

, or more, cable.

However, in order to reduce noise, make the wiring as short as possible.
This sensor is suitable for indoor use only.
Do not use this sensor in places having excessive vapor, dust, etc., or
where it may come in direct contact with water, or corrosive gas.
Take care that the product does not come in direct contact with water,
oil, grease, or organic solvents, such as, thinner, etc.
Make sure that stress by forcible bend or pulling with 76N, or more, force
is not applied directly to the sensor cable joint.
This sensor cannot be used in an environment containing inflammable
or explosive gases.
Never disassemble or modify the sensor.

INSTRUCTION MANUAL

Digital Mark Sensor

Photoelectric Sensor

Thank you very much for using SUNX products. Please read this Instruction
Manual carefully and thoroughly for the correct and optimum use of this
product. Kindly keep this manual in a convenient place for quick reference.

Never use this product as a sensing device for personnel
protection.
In case of using sensing devices for personnel protec-
tion, use products which meet standards, such as
OSHA, ANSI or IEC etc., for personnel protection ap-
plicable in each region or country.

٨

٨

WARNING

٨
٨
٨
٨

٨

٨

٨

٨
٨

٨

٨

٨

٨

٨
٨

٨
٨

٨

٨

٨

٨

10

15

SPECIFICATIONS

1

Notes: 1)

2)

The connector type LX-101

غ

-Z is 100mA.

The connecting cable is not supplied as an accessory for the connector type
LX-101

غ

-Z. Make sure to use the optional cables with connector below:

CN-24B-C2 (Straight type, 4-core, Cable length: 2m) CN-24BL-C2 (Elbow type, 4-core, Cable length: 2m)
CN-24B-C5 (Straight type, 4-core, Cable length: 5m) CN-24BL-C5 (Elbow type, 4-core, Cable length: 5m)

Max. sink current: 50mA
Applied voltage: 30V DC or less

(between output 2 and 0V)

Residual voltage: 1.5V or less

(at 50mA sink current)

NPN open-collector transistor

<NPN output type>

Max. source current: 50mA
Applied voltage: 30V DC or less

(between output 2 and +V)

Residual voltage: 1.5V or less

(at 50mA source current)

PNP open-collector transistor

<PNP output type>

Incorporated

Incorporated OFF-delay timer/ON-delay timer, switchable either effective or ineffective

'RUN': Green LED, 'TEACH', 'ADJ', 'COLOR', 'TIMER', 'PRO': Yellow LED

MODE indicator

Response time

Operation indicator

Mark mode: 2-level teaching/Full-auto teaching, Color mode: 1-level teaching

Sensitivity setting

Incorporated

IP67 (IEC)

4 digits red LED display

Orange LED (lights up when output 1 is ON)

Mark mode: 45

Ǵ

s or less, Color mode: 150

Ǵ

s or less

Digital display

Timer function

Protection

Fine sensitivity adjustment function

Material

Ambient temperature

120g approx.

55g approx.

Weight

Enclosure: PBT, Display: Polycarbonate, Operation buttons: Silicon rubber, Lens: Glass

0.2mm

2

5-core cabtyre cable, 2m long

Cable

35 to 85% RH, Storage: 35 to 85% RH

-10 to +55

͠

(No dew condensation or icing allowed), Storage: -20 to +70

͠

Ambient humidity

Red/green/blue LED

Emitting element

Current consumption

Teaching input

Supply voltage

Setting distance

Output 1

(OUT)

Item

Normal mode: 750mW or less (Current consumption 30mA or less at 24V supply voltage)
EOC mode: 600mW or less (Current consumption 25mA or less at 24V supply voltage)

12 to 24V DC+/-10%

˴

Ripple P-P10% or less

10mm

r

3mm

Low (ON): 0 to 2V DC

Source current 0.5mA or less
Input impedance 10k

ǡ

approx.

High (OFF): 5V to +V DC, or open

<NPN output type>

High (ON): 5V to +V DC

Sink current 0.5mA or less

Input impedance 10k

ǡ

approx.

Low (OFF): 0 to 0.6V DC, or open

<PNP output type>

Max. sink current: 50mA (Note 1)
Applied voltage: 30V DC or less

(between output 1 and 0V)

Residual voltage: 1.5V or less

at 50mA (Note 1) sink current

NPN open-collector transistor

<NPN output type>

Max. source current: 50mA (Note 1)
Applied voltage: 30V DC or less

(between output 1 and +V)

Residual voltage: 1.5V or less

at 50mA (Note 1) source current

<PNP output type>

PNP open-collector transistor

LX-101-P-Z

LX-101-P

LX-101-Z

LX-101

Connector type

Cable type

NPN output

PNP output

Type

Model
No.

Mark mode: Light-ON/Dark-ON Auto-setting method on teaching,
Color mode: Coincidence-ON/Non-coincidence-ON

Output operation

Incorporated

Short-circuit protection

Inverted operation of the output 1

Output operation

Short-circuit protection

Output 2 (Inversion output)

(OUT)

MOUNTING

3

PART DESCRIPTION

4

I/O CIRCUIT DIAGRAMS

5

Notes: 1)

2)

The output 2 is not incorporated to connector type LX-101

غ

-Z.

The current of the connector type LX-101

غ

-Z is 100mA.

NPN output type

D

2

10k

ǡ

D

1

1

4

12 to 24V DC

r

10%

Terminal No. of Connector Color code of cable type/cable with

connector

(Brown) +V

(Black) Output 1

50mA max. (Note 2)

50mA max. (Note 2)

(White) Output 2 (Note 1)

3

Z

D1

Z

D2

(Blue) 0V

T

r1

T

r2

(Pink) Teaching input

*1

5V

2

Sensor

circuit

Users' circuit

Internal circuit

Load

Load

Do not make the
sensor detect an
object in this di-
rection because it
may cause unsta-
ble operation.

Good

No good

Care must be taken regarding the
sensor mounting directrion with
respect to the object's direction of
movement.

The tightening torque should be
0.8N

m or less.

Sensor mounting
bracket
MS-LX-1
(Optional)

M4 screw with washers

COLOR
TIMER

OPE.

RUN

ADJ.

TEACH

Operation indicator
(Orange)

MODE/CANCEL key

OFF/ENTER key

ON/SELECT key

MODE indicator / RUN (Green)

MODE indicator / ADJ (Yellow)

MODE indicator / TEACH (Yellow)

MODE indicator / TIMER (Yellow)

MODE indicator / COLOR (Yellow)

MODE indicator / PRO (Yellow)

Digital display (Red)

Summary of Contents for LX-100

Page 1: ... Residual voltage 1 5V or less at 50mA sink current NPN open collector transistor NPN output type Max source current 50mA Applied voltage 30V DC or less between output 2 and V Residual voltage 1 5V or less at 50mA source current PNP open collector transistor PNP output type Incorporated Incorporated OFF delay timer ON delay timer switchable either effective or ineffective RUN Green LED TEACH ADJ C...

Page 2: ...irm Note 1 ZD3 ZD4 12 to 24V DC r10 Pink Teaching input 2 D4 D3 10kǡ 4 3 Tr3 Tr4 50mA max Note 2 Blue 0V 0V 2 Terminal No of Connector Color code of cable type cable with connector Brown V Sensor circuit Black Output 1 White Output 2 Note 1 Users circuit Internal circuit Load Load NAVI mode Run RUN At mark mode setting Indicates the absolute value of emitting amount It is possible to indicate the ...

Page 3: ...d on the digital display Slow down the speed of the assembly line and carry out the teaching again In case stable sensing is possible In case stable sensing is impossible Note If the output is gained on the opposite side against the side desired to the step carry out the teaching again In this case note that when carrying out the teaching for this measurement press the different key from the one p...

Page 4: ...ec or more sampling begins When sampling finishes the digital display flashes If is displayed slow down the line speed and carry out the teaching again 1 level teaching Align the beam spot to the mark to be detected in RUN mode Input the external signal for 20ms or more in step state In case of color mode Timing chart OUTPUT 2 INVERSION OUTPUT OUT For LX 101 غ type only The LX 101 غ cable type inc...