Sunvic SunPro2000 Installation Instructions Download Page 2

Installation Instruction Leaflet: LE/0497/0005/Nov2011/Rev00 

 

 

 

 

 

Page 2 of 3

 

 

 

6) Temperature Control function – selectable 
range 5~35°C 

 
a)  This function enables the programmer to act as a 

programmable room thermostat. 

 
b)  This function is activated by fitting one of the 

jumpers (provided) in the 

 location, 

on the rear of the programmer, prior to 
installation. 

 

c)  Reset the programmer after fitting the above 

jumper. A blunt, non metallic instrument should 
be used to press the reset button. 

 
d)  Please note that when the Temperature Control 

function is activated the original programmed 
ON/OFF times are overridden when the set room 
temperature reached. 

 

7) Setting the room temperature 

 
a)  Move the selection switch to the “RUN” position 

  

b) 

Press both the

and the 

buttons 

to select any of ON, 3, 2 or 1 position (i.e. “ON 3 
2 1 OFF”). 

 

c) 

Hold down both the “+” and “-” buttons at the 
same time for 5 seconds to enter the selection 
mode. 

 

d) 

Press either the “+” and “-” buttons to set the 
room temperature set point (between 5~35°C). 

 

e) 

Press the “OK” button to activate the selected set 
point. 

 

f) 

N.B.

 when both Frost Protection and 

Temperature Control are activated and the unit is  
in RUN mode holding down the “+” and “-” 
buttons at the same time for 5 seconds will firstly 
allow the user to change or confirm the room 
temperature and then the Frost Protection 
temperature. 

 

8) Replacing the battery 
 

Use a flat-headed screwdriver to remove old battery 
and replace with a new battery as per Fig 1 to Fig 3. 

 

Fig 1 

 

      Fig 2               

   Fig 3 

i

 Always replace the battery with one of the same 

type.  Use only a 

3V DC Lithium CR 2032 battery. 

 

 

 
 
 
Please note that interference with sealed parts will 
render the guarantee void.  
 

SUNVIC CONTROLS Ltd. 
Units 1 & 2, Block 1 
251 Low Waters Road 
Cadzow Industrial Estate 
Hamilton 
ML3 7QU 
 
Tel. +44 (0)1698 812944 
Fax +44 (0)1698 813637 
Technical He44 (0)1698 810945 
 
N.B.

 In line with a policy of continuous product 

development, SUNVIC CONTROLS Ltd. reserves the 
right to change the specification, design and 
materials of products without prior notice. 

 
SunPro2000 WIRING COMPATABILITY 
 

It is the installer’s responsibility to examine the 
existing programmer to ensure that the wiring is 
following charts are for reference only. 
 

Direct replacement for existing programmers 

 
The SunPro2000 will fit directly onto existing back 
plates of the programmers shown, on the chart 
below, without any rewiring. Otherwise fit using the 
new wiring interchange guide 

 

 
 
 
 
 
 
 
 
 

Manufacturer

Model 

Sunvic 
Controls 

Select 207XLS, Select 207XL, 
Simplex 200 

ACL-Drayton 

LP112, LS241, LS522, LS722, 
LP241, LP522, LP722,  Tempus 3, 
Tempus 4, Tempus 6,  Tempus 7 

Danfoss 
Randall 

FP15, FP72,  FP75, CP15, CP72, 
Cp75, MP15, MP75 

Gloworm Mastermind 

Landis & Gyr 

RWB2, RWB9, RWB20, RWB40, 
RWB102, RWB200, RWB252 

Potterton Mini 

Minder 

Siemens RWB29 

Towerchron DP72, 

QE2 

Safe Disposal

Do not dispose of the battery 
with household rubbish. 
Batteries must be returned in 
accordance with the local 
statutory requirements.

Reviews: