6) Temperature Control function – selectable
range 5~35°C
a) This function enables the programmer to act as a
programmable room thermostat.
b) This function is activated by fitting one of the
jumpers (provided) in the
location,
on the rear of the programmer, prior to
installation.
c) Reset the programmer after fitting the above
jumper. A blunt, non metallic instrument should
be used to press the reset button.
d) Please note that when the Temperature Control
function is activated the original programmed
ON/OFF times are overridden when the set room
temperature reached.
7) Setting the room temperature
a) Move the selection switch to the “RUN” position
b)
Press both the
and the
buttons
to select any of ON, 3, 2 or 1 position (i.e. “ON 3
2 1 OFF”).
c)
Hold down both the “+” and “-” buttons at the
same time for 5 seconds to enter the selection
mode.
d)
Press either the “+” and “-” buttons to set the
room temperature set point (between 5~35°C).
e)
Press the “OK” button to activate the selected set
point.
f)
N.B.
when both Frost Protection and
Temperature Control are activated and the unit is
in RUN mode holding down the “+” and “-”
buttons at the same time for 5 seconds will firstly
allow the user to change or confirm the room
temperature and then the Frost Protection
temperature.
8) Replacing the battery
Use a flat-headed screwdriver to remove old battery
and replace with a new battery as per Fig 1 to Fig 3.
Fig 1
Fig 2
Fig 3
i
Always replace the battery with one of the same
type. Use only a
3V DC Lithium CR 2032 battery.
Please note that interference with sealed parts will
render the guarantee void.
SUNVIC CONTROLS Ltd.
Units 1 & 2, Block 1
251 Low Waters Road
Cadzow Industrial Estate
Hamilton
ML3 7QU
Tel. +44 (0)1698 812944
Fax +44 (0)1698 813637
Technical He44 (0)1698 810945
N.B.
In line with a policy of continuous product
development, SUNVIC CONTROLS Ltd. reserves the
right to change the specification, design and
materials of products without prior notice.
SunPro2000 WIRING COMPATABILITY
It is the installer’s responsibility to examine the
existing programmer to ensure that the wiring is
following charts are for reference only.
Direct replacement for existing programmers
The SunPro2000 will fit directly onto existing back
plates of the programmers shown, on the chart
below, without any rewiring. Otherwise fit using the
new wiring interchange guide
Manufacturer
Model
Sunvic
Controls
Select 207XLS, Select 207XL,
Simplex 200
ACL-Drayton
LP112, LS241, LS522, LS722,
LP241, LP522, LP722, Tempus 3,
Tempus 4, Tempus 6, Tempus 7
Danfoss
Randall
FP15, FP72, FP75, CP15, CP72,
Cp75, MP15, MP75
Gloworm Mastermind
Landis & Gyr
RWB2, RWB9, RWB20, RWB40,
RWB102, RWB200, RWB252
Potterton Mini
Minder
Siemens RWB29
Towerchron DP72,
QE2
Safe Disposal
Do not dispose of the battery
with household rubbish.