ST3300 User Manual
19
0 – Disable
Range : 1 ~ 21600 (5hour)
Recommend : 600 ( 10 min.)
MOTION_THRES
String
Step
Detection level of shock violation.
Range : 0.04 ~ 2.0
Recommend : 0.04
SHOCK_THRES
String
Step
Detection level of shock violation.
Range : 0.04 ~ 2.0
Recommend : 0.04
COLL_THRES
String
Step
Gravity for collision report.
Range : 0.1 ~ 2.0
Recommend : 0.7
VI_ON_THRES
String
1/255G Threshold value for Motion Virtual Ignition On
Range : 3~50
Default : 5
VI_ON_DELAY
String
Sec.
Delay time for Motion Virtual Ignition On
Range : 3~999
Default : 10
VI_ON_PERCENT
String
%
Percent for Motion Virtual Ignition On.
Range : 30~100
Default: 70
VI_OFF_THRES
String
1/255G Threshold value for Motion Virtual Ignition Off
Range : 3~50
Default : 5
VI_OFF_DELAY
String
Sec.
Delay time for Motion Virtual Ignition Off
Range : 3~999
Default : 10
VI_OFF_PERCENT
String
%
Percent for Motion virtual Ignition Off.
Range : 30 ~ 100
Default : 70
<example>
[command] ST3300MSR;;02;600;0.04;0.04;0.7;5;10;70;5;10;70
[response] ST3300MSR;Res;852588;128;600;0.04;0.04;0.70;5;10;70;5;10;70
<notes>
* For the shock level, we recommend it to set to 0.04. if it's over than 0.04, the sensor will be more
insensitive