![SunTech ST25T Operation Manual Download Page 13](http://html.mh-extra.com/html/suntech/st25t/st25t_operation-manual_1400909013.webp)
Doc. Title
Author
Page of Pages
ST25T OPERATION MANUAL
JH Sim
13 of 16
Concerning
Doc. No.
Rev.
Date
Features and How to set parameters
1.00
15 Jan 2019
Suntech International Ltd.
Confidential Document
END OF LINE
\r\n
String
[Command]
$EVT_UART_FUEL_CON;ST25T;0;0
5-2-5. Uart Fuel Sensor Disconnected Event
Field
Value
Format
Description
CMD
$EVT_UART_FUEL_DISCON
String
Command
MODEL
ST25T
String
Model name
FUEL_NUM
0 ~ 5
1byte int
Fuel sensor number
0 = RS232 Fuel 1
1 = RS232 Fuel 2
2 = RS485 Fuel 1
3 = RS485 Fuel 2
4 = RS485 Fuel 3
5 = RS485 Fuel 4
FUEL_LEVEL
0
2bytes int Fuel sensor level
END OF LINE
\r\n
String
[Command]
$EVT_UART_FUEL_DISCON;ST25T;0;0
5-2-6. Uart Fuel Sensor Upper Event
Field
Value
Format
Description
CMD
$EVT_UART_FUEL_UPPER
String
Command
MODEL
ST25T
String
Model name
FUEL_NUM
0 ~ 5
1byte int
Fuel sensor number
0 = RS232 Fuel 1
1 = RS232 Fuel 2
2 = RS485 Fuel 1
3 = RS485 Fuel 2
4 = RS485 Fuel 3
5 = RS485 Fuel 4
FUEL_LEVEL
0 ~ 4095
2bytes int Fuel sensor level
END OF LINE
\r\n
String
[Command]
$EVT_UART_FUEL_UPPER;ST25T;0;0
5-2-7. Uart Fuel Sensor Lower Event
Field
Value
Format
Description
CMD
$EVT_UART_FUEL_LOWER
String
Command
MODEL
ST25T
String
Model name
FUEL_NUM
0 ~ 5
1byte int
Fuel sensor number
0 = RS232 Fuel 1