DRAINAGE 

 

During the process of cooling some water will be extracted from the air into the unit. If the reservoir is 
full, both the compressor and motor will stop and the units would buzz (you can press any button to stop 
the buzz), only the fan runs to circulate the air. The W.F. indicator will flash to show you. 
 

To make the cooling work again, please empty the water by one of the following ways:  

 

1. 

Turn off the air conditioner and avoid 
moving it while full.

 

2.  Position a container (a water tray e.g.) 

underneath the drain hole. 

3.  Remove the drain knob & rubber plug 

from the drain hole and allow the water 
to drain out. 

4. 

When the container is almost full, 
replace the rubber plug in the drain hole 
to stop the water and empty the water 
tray.

 

5. 

Repeat until the unit is emptied. 

 

6.  Replace the rubber plug and tighten the 

drain knob firmly. 

7.  Switch on the unit – the full water or 

compressor indicator should not be 
flashing. 

 

 
 

 

 
 

By water tube (continuous drainage) 

 

1.  Remove the drain knob and rubber 

plug and retain for future use. 

 

2.  Connect the drain tube supplied to the 

water outlet as shown and locate the 

other end into a drain. 

  

3.  The drain tube may be extended by 

adding an extension tube and using a 
suitable connector. 

 

NOTE: The drain must be at or below the 

outlet level. Flashing comp/”full water” 

indicator will not function in this mode of 

drainage. If you want to extend the water 

tube connect it with another tube 

(OD:18mm) 

 

 

 

 
 

Summary of Contents for Klimatronic Progress 9.0 plus

Page 1: ...Dynamic Read and retain these instructions for future reference Dynamic 7 0 plus Dynamic 9 0 plus...

Page 2: ...r supply 230V 50Hz 1phase Recommended room size 10 18m 2 14 24m 2 Compressor rotary Power supply 230V 50Hz 1phase Refrigerant R 410 A Refrigerant load 350 g 390 g Fan speed 2 Timer 1 12 hours Working...

Page 3: ...ion manual Always place the unit on a stable ground base FIG 1 The unit must always stand or be transported in a vertical position Do not cover or obstruct the appliance s inlet and outlet Grilles FIG...

Page 4: ...ilter Especially younger elder and disabled people are often not aware of the danger that might occur from the usage of electrical appliances Therefore the product should never be used without supervi...

Page 5: ...window 14 Exhaust hose 15 Foam strip for filling the open window space and with hole for connection to exhaust hose 16 Foam strip for filling the open window space 17 Round cap for filling the hole in...

Page 6: ...r flow to the outside If necessary cut off the extra part to fit the window Feed exhaust hose through the foam strip and insert strip into window gaps as shown and slide window across so that foam is...

Page 7: ...t possible length 2 Avoid kinks and bends in the exhaust hose as this will cause expelled moist air to build up causing the unit to overheat and shut down WARNING The length of the exhaust pipe is spe...

Page 8: ...low or equal to 23oC the unit will work in ventilation model below 20oC the unit will work in heating function This is for cooling heating models only 2 Indicators of the functions in progress come on...

Page 9: ...s you press TIMER button If the timer button is not pressed the unit will work continuously 2 By the machine to work For example if you press the timer to 2 the unit will work automatically after 2 ho...

Page 10: ...the carbon filter 1 Remove the filter frame from the unit 2 Remove the active carbon filter from its plastic bag 3 Insert the active carbon filter into the back of the unit 4 Re fit the filter frame...

Page 11: ...out 4 When the container is almost full replace the rubber plug in the drain hole to stop the water and empty the water tray 5 Repeat until the unit is emptied 6 Replace the rubber plug and tighten t...

Page 12: ...ers and then rinse thoroughly under running water no hotter than 40 C Dry thoroughly before replacing Notice Never operate the unit without the filters End of season storage Unplug the unit Drain the...

Page 13: ...erature Too noisy Is the machine positioned unevenly so as to create vibration Is the floor underneath the machine uneven The compressor doesn t run Is so it is possible the overheat protection of the...

Reviews: