2.7.Thermostat (option).
sheme 1
The thermostat may be adjusted by the
user within the range 30°С ÷ 80°С, and the
thermal protection would go off in case
the water reaches 95°С.
This is an adjustable double THERMOSTAT
which is designed to regulate the water
temperature and ensures safety tolerance;
it can be manually adjusted (TLSC model)
or automatically adjusted (TLSC/A model).
CONFORMITY TO STANDARDS
This product is in conformity with:
- EN 60730-1 and subsequent editions;
- EN 60730-2-9
CONFORMITY TO REGULATIONS
This product complies with:
- Low Voltage Directive 73/23 EEC
- Electromagnetic Compatibility Directive
89/336/EC
TECHNICAL CHARACTERISTICS
Temperature range – regulation- 0°C ÷
90°C;
limit - 90°C ÷ 110°C;
Tolerance
Regulation
± 5k,
limit – 15 k; -6 k (depends on the type)
Temperature differential
Regulation 6 ± 2 k; 4 ± 1 k (depends
on the type)
Limit 25 ± 8 k; 15 ± 8 k (depends on
the type)
Automatic adjustment (TLSC/A) and
manual adjustment (TLSC).
Degree of protection = IP 40
Insulation class = I.
Temperature change rate = <1К/min.
Maximal temperature point: 80°C
Maximal temperature for electric lamp:
125°C
Accumulation temperature: 15°C ÷ 55°C
Maximum pressure of the cartridge: 10
bar
Constant time: < 1“
Electric connection
:
C-1 ADJ.:10(2,5)A/250V°;
C-2 ADJ.:6(2,5)A/250V~;