SunSynk SUN-BATT-5.12R User Manual Download Page 17

  

 

  

 

 

 

 

 

 

 

Page | 17

SUN-BATT-5.12R | Installer Manual

  

 

  

 

 

 

 

 

 

 

Each SUN-BATT-5.12R has two pairs of power cable terminals, two P+, and two P-. The con-
nec- tion terminals of each pair have the same function.

Single Module

In a single module application, any of the terminals of each pair can be used.

Parallel System

Multiple batteries can be connected in parallel to expand the capacity and power. When using 
multiple batteries in parallel, one will operate as a master and the others as slaves. One of the 

Master

 pack P+ terminals should connect to the PCS, and the other should connect to another 

battery for capacity expansion.

One of the P- terminals of the last 

Slave

 pack should connect to PCS, and the other should 

connect to another battery for capacity expansion.

For the other 

Slave

 packs, each P terminal should be connected to another battery's terminal.

4.2.  Parallel Cascade Connection

4.2.1.  Power Cable Wiring Instructions 

The connection to the protection devices should use the P+ terminal from the Mas-

ter pack and the P- terminal from the last Slave pack.

The Master battery can automatically identify the Slaves batteries connected in parallel using 
its internal software control. The communication terminals Port In and Port Out (RJ45 port) are 
integrated with the signal for automatic coding function. 

The following describes the connections of a system with four batteries packs, one Master, and 
three Slaves.

 

ƒ

The 

CAN

 communication port of the 

Master pack should connect to PCS

;

 

ƒ

Port In from the Master pack should not be connected;

 

ƒ

The Port Out from the master PACK should connect the Port In of the first slave PACK using 
a parallel communication wire;

 

ƒ

The Port Out of the first Slave pack should connect to the Port In of the second Slave PACK;

 

ƒ

Following the same pattern, the Port Out of the second Slave pack should connect to the 
Port In of the third Slave PACK;

 

ƒ

The Port Out of the third and last slave PACK should not be connected.

4.2.2.  Communication Cable Connections

Summary of Contents for SUN-BATT-5.12R

Page 1: ...v 2 09 30 22 Global Tech China Ltd 3 Floor Wai Yip Industrial Building 171 Wai Yip Street Kwun Tong Kowloon Hong Kong Tel 852 2884 4318 Fax 8522884 4816 www sunsynk com sales globaltech china com SUN...

Page 2: ...ounted Accessory Deliverables 9 3 2 2 Wall Mounted Accessory Deliverables 10 3 3 Tools 11 3 4 Installation Requirements 11 3 4 1 Installation Environment Requirements 11 3 4 2 Installation Carrier Req...

Page 3: ...ification Dimension W D H mm 440 550 130mm Weight Kg 49kg Installation Rack Mounted Wall Mounted or Cabinet Mounted Working Temperature2 20 C 60 C Storage Temperature 25 C 12 months 35 C 6 months 45 C...

Page 4: ...tery temperature 1 Test conditions 100 depth of discharge DoD 0 2C rate charge discharge at 25 C 2 Charge discharge derating occurs when the operating temperature from 10 C to 5 C 45 C to 55 C 3 Condi...

Page 5: ...Page 5 SUN BATT 5 12R Installer Manual 1 1 2 Wall Mounted SUN BATT 5 12R 1 1 3 Cabinet Mounted SUN BATT 5 12R...

Page 6: ...l at most 2 1 Brief Introduction 2 2 Interface Introduction 2 2 1 Switch ON OFF Switch ON For single SUN BATT 5 12R switch ON rocker switch then long press more than 3 seconds ON OFF button on front p...

Page 7: ...OFF Stop discharge Fault OFF Light OFF OFF OFF OFF OFF OFF Stop charging and Discharge Charging Battery Level Indicators Instructions Status Charging Battery Level Indicator L8 L7 L6 L5 L4 L3 L2 L1 B...

Page 8: ...ion Pin 1 Pin 8 RS485 B to PCS reserved Pin 2 Pin 7 RS485 A to PCS reserved Pin 3 NC Pin 4 CANH to PCS Pin 5 CANL to PCS Pin 6 GND 2 2 4 RS232 Port RS232 Communication Terminal RJ45 port follow RS232...

Page 9: ...or damage such as holes and cracks If any damage is found do not unpack the battery and contact the dealer as soon as possible You are advised to remove the packing materials within 24 hours before in...

Page 10: ...Battery 2 4PCS Support frame 3 12PCS M4 8 4 8PCS M6 50 5 1PCS Manual 6 1PCS Test report 7 1PCS Certificate 3 2 2 Wall Mounted Accessory Deliverables NO Pictures Quantity Description 1 2PCS Hanging bra...

Page 11: ...rements Install the battery in the indoor environment Place battery in secure location away from children and animals Do not place the battery near any heat sources and avoid sparks Do not expose the...

Page 12: ...Page 12 SUN BATT 5 12R Installer Manual 3 5 1 Dimensions 3 5 Installation Instructions...

Page 13: ...staller Manual 3 5 2 Installation Steps Rack Mounted STEP 1 Remove the handle from the battery STEP 2 Install Support frames at the four corners of the battery STEP 3 The battery with the support fram...

Page 14: ...BATT 5 12R Installer Manual 3 5 3 Installation Steps Wall Mounted Minimum mounting distance requirement Wall Mounted STEP 1 Drill the hole with an 10mm drill bit as follows and fix the wall bracket t...

Page 15: ...Page 15 SUN BATT 5 12R Installer Manual STEP 2 Install the wall hanging bracket STEP 3 Hang the machine on the wall hanging back plate and tighten it...

Page 16: ...BATT 5 12R Installer Manual Page 16 4 BATTERY POWER AND COMMUNICATION CONNECTIONS 4 1 Wiring Steps STEP 1 Connect the battery to ground STEP 2 Connect the battery power line STEP 3 Connect the communi...

Page 17: ...able Wiring Instructions The connection to the protection devices should use the P terminal from the Mas ter pack and the P terminal from the last Slave pack The Master battery can automatically ident...

Page 18: ...Page 18 SUN BATT 5 12R Installer Manual 4 2 3 Wiring Diagram for Parallel Cascade Connection When multiple batteries are connected in parallel follow the following wiring mode...

Page 19: ...umidity of Storage Environment Storage Time SOC Below 10 C prohibit 10 25 C 5 70 12 months 30 SOC 60 25 35 C 5 70 6 months 30 SOC 60 35 45 C 5 70 3 months 30 SOC 60 Above 45 C prohibit 5 2 Recharge Re...

Page 20: ...g 171 Wai Yip Street Kwun Tong Kowloon Hong Kong Tel HK 852 2884 4318 Fax 852 2884 4816 Tel UK 44 151 528 9945 Tel SA 27 1108 39837 sales globaltech china com Audio Training manuals on Apple Pod Cast...

Reviews: