Although ultraviolet radiation is the lowest in energy of all types of ionising radiation, it can be 
harmful to human beings and other organisms. Even UV radiation with a bigger wavelength is 
already able to destroy chemical bonds of organic molecules. It is therefore advisable to use 
technical UV sources responsibly. 

 

Only operate the tube inside a closed and intact housing. 

 

 Warning! 

Read all safety precautions and instructions.

 Failure to obey the safety precautions and instructions 

might cause an electric shock, a fire, and/or severe injuries. 
Keep all safety precautions and instructions for future use. 
 
 

Resistance 

 
The maximum temperature of the pumped liquid should not 35 

 in continuous operation. 

 
The pump must not be used to pump flammable, gassing, or explosive liquids. The pump must not be 
used to pump other liquids, especially motor fuels, cleaning agent, or other chemical products. 
 
 

Electrical connection 

 
The electrical connection is made to an earthed socket 230 V ~ 50 Hz. Fuse protection at least 6 A. 
 

 Caution! 

 

The UVC filter should be placed in such a way that no water may reach it. The minimum distance 
between the device and the pond is 2 m. The lamp is not suitable of underwater operation. 

 

The power supply of the UVC filter must not be switched on before water circulates inside the 
device. 

 

Place the UVC filter in a safe and stable place, as the sleeve of the filter is made of very fragile 
quartz glass. 

 

Do not switch on the power before all parts of the device are completely assembled. 

 

In case the quartz glass sleeve and the  upper part of the UVC filter are damaged, the device 
cannot be put into operation. 

 

The UVC filter must not be used if people are in the water. 

 

Make sure that the existing mains voltage and frequency match the specifications on the filter. 

 

While installing the device, local and national installation prescriptions must be obeyed. 

 

Do not pull on the power cord. Keep the cable away from heat, oil, or sharp edges. 

 

Make sure that the upper part is only exposed to a pressure below 0,3 bar. 

 

Remove the filter with frost announced. 

 

When installing the UV filter, do not expose it to direct sunlight. 

 

A dirty quartz crystal glass tube affects the efficiency of the device; thus, regularly clean it. 

 

For the device to keep its efficiency, the UV glass sleeve should be replaced after 8,000 hours 
of operation. 

 

UV radiation is harmful to eyes and skin. Do not directly look into the UV light and do not expose 
your skin to UV light. 

 

When installing or maintaining the device, switch off the power supply of the lamp and pump. 

 

The product must be mounted horizontally, the feet pointing downwards. For safety reasons, it 
is not allowed to install the device in another way. 

 

 

Summary of Contents for 51627

Page 1: ...milar may vary depending on model Please read and follow the operating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and tech...

Page 2: ...m https www wiltec de contacts The most recent version of this manual in several languages can be found in our online shop https www wiltec de docsearch Our postal address is WilTec Wildanger Technik...

Page 3: ...he device accordingly to the intended purpose stated in this manual You are responsible for the safety of the working zone If the cable or the plug is damaged due to external influences the cable must...

Page 4: ...of underwater operation The power supply of the UVC filter must not be switched on before water circulates inside the device Place the UVC filter in a safe and stable place as the sleeve of the filter...

Page 5: ...filter to pond Cleaning outlet from filter to sewers or flowerbed Use The pressure pond filter with integrated UV clarifier is a pressure filter system for biologically and mechanically filtering nor...

Page 6: ...is different In high speed zones blue filters microorganisms settle that convert ammo nium into nitrate In zones where the water flow rate is slower yellow filters mainly anaer obic microorganisms gat...

Page 7: ...thus it cannot come off Use a hose with the largest possible diameter With hoses longer than 4 m it is advisable to use a hose tail with the largest possible diameter To minimise pressure losses cut...

Page 8: ...lter sponges If the water flow is too low due to dirty filter sponges and cannot be improved by automatic cleaning the filter sponges must be cleaned or replaced Do not use any chemical cleaning agent...

Page 9: ...Full biological cleaning efficiency will be reached after a few weeks Insufficient pump power Switch off pump then switch it on Extremely dirty water Remove algae and leaves from pond or change water...

Page 10: ...signation Designation Designation 1 Screw 1 9 Lid 17 O ring 3 2 UV unit 10 Gasket 18 Container 3 O ring 1 11 Inlet and outlet 19 Screw 2 4 UV lamp 12 Connecting nut for inlet and outlet 20 Washer 5 O...

Page 11: ...n 1 Screw 1 9 Lid 17 Threaded ring 2 UV unit 10 Gasket 18 O ring 3 3 O ring 1 11 Inlet and outlet 19 Container 4 UV lamp 12 Flow ring for transparent set 20 Screw 2 5 O ring 2 13 Connecting nut for in...

Page 12: ...basket 2 UV unit 11 Inlet and outlet 20 Threaded ring 3 O ring 1 12 Flow ring for transparent set 21 O ring 3 4 UV lamp 13 Connecting nut for inlet and outlet 22 Container 5 O ring 2 14 Filter sponge...

Page 13: ...earing 2 UV unit 11 Inlet and outlet 20 Cleaning set 3 O ring 1 12 Flow ring for transparent set 21 Motor 4 UV lamp 13 Connecting nut for inlet and outlet 22 Cover of filter basket 5 O ring 2 14 Filte...

Page 14: ...esignation 1 Screw 1 9 Lid 17 Threaded ring 2 UV unit 10 Gasket 18 O ring 3 3 O ring 1 11 Inlet and outlet 19 Container 4 UV lamp 12 Connecting nut for inlet and outlet 20 Screw 2 5 O ring 2 13 Filter...

Page 15: ...Screw 1 10 Gasket 19 O ring 3 2 UV unit 11 Inlet and outlet 20 Container 3 O ring 1 12 Connecting nut for inlet and outlet 21 Screw 2 4 UV lamp 13 Filter sponge 22 Washer 5 O ring 2 14 Filter sponge i...

Page 16: ...w 1 10 Inlet and outlet 19 Rubber seal 2 UV unit 11 Connecting nut for inlet and outlet 20 Threaded ring 3 O ring 1 12 Filter sponge 21 Cover of filter basket 4 UV lamp 13 Filter sponge inset 22 Bio b...

Page 17: ...ications Model Item number UV power W Max flow rate h Inlet and out let Capacity h CPA 2500 51627 11 6000 19 40 1 16 CPA 5000 51628 11 9000 19 40 1 20 CPA 10000 51629 11 10 000 19 40 1 25 CPA 15000 51...

Page 18: ...countries of the European Union and other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product mu...

Reviews: