GRILL START-UP – LIGHTING THE GRILL

 

PAGE 14 

REMOVE COVER & OPEN VENT 

1. Ensure Grill Control Knobs 
are In the OFF position, turn 
either KNOB to High Position. 

2. Light the Main Burners by turning 

either one KNOB counter-clockwise to 

HIGH

 Push in and SLOWLY turn. Allow 

Gas to Completely Fill the IR Burner 

chamber.

 

3. You will hear a loud click as the 

electronic lighter produces a spark. 

Listen for the sound of the gas igniting 

and look for a flame through the cooking 

grids.  If the burner does not light on the 

first try, repeat immediately. 

5. If the burner does not light in 5 

seconds then wait five minutes until 

the gas clears before attempting to 

light it again. Repeat the procedure 

or try the manual lighting options on 

6. Upon successful lighting, repeat the 

process on the other burner.  

7. To shut off the burners, rotate the 

knob and turn to OFF. 

8. It is normal to hear a popping sound 

when the burners are turned off. 

REMOVE COVER WHEN  

LIGHTING THE GRILL & OPEN 

BACK VENT PANEL 

4. The Gas must completely fill the 

entire IR-Burner so repeat this until IR 

Burner lights all the way across and 

stays lit.   

Summary of Contents for Ruby Companion Pro

Page 1: ...you operate your grill Save these instructions To installer or person assembling grill Leave this manual with grill for future reference To consumer Keep this manual for future reference www sunstone...

Page 2: ...k Please make sure you have the following information MODEL NUMBER DATE OF PURCHASE INVOICE NUMBER For warranty service contact SUNSTONE Customer Service Department at 888 934 9449 or email service su...

Page 3: ...SION Indicates an imminently hazardous situation which if not avoided will result in possible explosion and cause death or severe injury BODILY INJURY Indicates a potentially hazardous situation which...

Page 4: ...e maintained All packaging has been removed from Interior of Grill All parts and components are properly installed An installer supplied manual gas shut off valve is fully accessible LP hose is clean...

Page 5: ...SUN13CPRO MANI 16 Piezo Valve LP NG 2 SUN13CPRO VALVE LP NG 17 Fire Box 1 SUN13CPRO FBOX 18 Knob Ring 2 P KNOB RING 19 Knob Control Panel 1 SUN13CPRO KCPANEL 20 Thermo Coupler 2 SUN13CPRO THERMO 21 Oi...

Page 6: ...GRILL PARTS PARTS DIAGRAM PAGE 2...

Page 7: ...Elect Connection Locate the Light Button on Left side of grill control panel The Transformer s electrical connection to grill is located behind control panel next to light button The connection clips...

Page 8: ...ll the way into cut out there is a stopper flange just behind the back vent which will insure the area stays clear for adequate air flow to the bottom burners The Control Panel should be flush against...

Page 9: ...3 4 Box Depth includes flange 22 1 2 GRILL INSTALLATION PRODUCT DETAILS PAGE 5 Technical Measurements If you are installing grill into cabinet structure you may need to refer to these engineer dimens...

Page 10: ...allation A Grill Cut out Depth 22 Depth B Grill Cut out Height Allow Air Flow Gap Below Drip Pan 10 1 2 Height C Grill Cut out Width 11 Width D Make 1 x1 D Notch Cut Out on both side of cut out counte...

Page 11: ...ior outside wall or roof and there is a Minimum of Two adjacent sides which are open with outside exposure PAGE 7 ATTENTION All Gas Grill Installations MUST HAVE MINIMUM TWO AIR FLOW VENTS either in E...

Page 12: ...lor or damage unprotected areas do not install under unprotected combustible construction without using a fire safe ventilation system A 24 minimum clearance must be maintained under the countertop to...

Page 13: ...our Warranty may be VOID if island does not meet basic setup requirements GRILL INSTALLATION ENCLOSED INSTALLATION PAGE 9 Enclosed Installation Definition Structure built above Appliance that is attac...

Page 14: ...ake sure BBQ Grill control knobs are in OFF position Verify the type of gas supply to be used either Natural Gas or Liquid Propane and make sure the marking on the appliance rating label agrees with t...

Page 15: ...me with an independent LP regulator for this type of installation Contact the company you purchased from or your local plumber to locate one that is made for commercial style grills Large Capacity LP...

Page 16: ...mit the flow of gas to 10 cubic feet per hour NEVER use grill without leak testing GAS SETUP MEDIUM CAPACITY LP TANKS PAGE 12 Follow Instructions 1 The tank valve all Knobs should be in the OFF positi...

Page 17: ...ATURAL GAS INSTALLATION PAGE 13 Follow Instructions 1 The tank valve all Knobs should be in the OFF position If not turn the knob clockwise until it stops 2 Insert the regulator inlet into the tank va...