SUNSTAR RESIDENTIAL INSTALLATION MANUAL
22
COLLECTOR ROOF MOUNTING – SHINGLE ROOFS
(CONTINUED)
7.
Ensure that all mounts are properly anchored & sealed into the roof and all top collector
manifolds are connected with PPCs. Move to the lower side of the collectors.
8.
Locate and mount the bottom mounting pads on the mounting tracks opposite those
on the upper manifold. The bottom mounting pads should be mounted in the same
way and mirror those on the upper manifold. See details later in this manual on how
the bottom mounting pad assembly functions.
9.
Slide the bottom mounting pads onto the tracks opposite the top mounting pads.
These should be aligned along the same truss
10.
Pipe supports should be used at the feed and return
piping connected to the collector banks(s).
Fig. 5
A
B
C