Form 43343320
Aug 2012
-35-
D.
D.
D.
D.
LOW VOLTAGE (24V) THERMOSTAT CONNECTIONS
LOW VOLTAGE (24V) THERMOSTAT CONNECTIONS
LOW VOLTAGE (24V) THERMOSTAT CONNECTIONS
LOW VOLTAGE (24V) THERMOSTAT CONNECTIONS –
–
–
– MULTIPLE HEATERS (utilizing a f
MULTIPLE HEATERS (utilizing a f
MULTIPLE HEATERS (utilizing a f
MULTIPLE HEATERS (utilizing a fan center
an center
an center
an center
relay)
relay)
relay)
relay)
Burner Control Box
Ground
N Neutral
L1 Hot (120V)
Low voltage
thermostat (24V)
Continue To
Additional
Heaters
Power Supply
Cord (120V)
Receptacle
TH
C
Jumper factory
installed for optional
24V thermostat
Fused
Disconnect
switch
24V
coil
C
R
G
NO
TH
C
Fan Center Relay Part No. 30169000
Contact Rating: 120V, 40VA, 12A
(maximum of 6 heaters per relay)
16.0)
VENTING
Failure to do so may result in death, serious injury, property damage or illness
from Carbon Monoxide poisoning.
Heaters installed in an unvented mode require a minimum ventilation flow of
4 CFM per 1,000 Btu/hr of total installed capacity.
In buildings with airborne contamination the heater must be installed with
fresh air for combustion.
CARBON MONOXIDE HAZARD
A.
A.
A.
A.
BASIC FLUE VENTING
BASIC FLUE VENTING
BASIC FLUE VENTING
BASIC FLUE VENTING — Venting must comply with the latest edition of the National Fuel Gas Code (ANSI
Z223.1-latest edition) or the authority having jurisdiction. Other venting references are in the equipment
volume of the ASHRAE Handbook.
Model
Model
Model
Model
Heat
Heat
Heat
Heat
exchanger
exchanger
exchanger
exchanger
length ft
length ft
length ft
length ft
Maximum vent length ft.
Maximum vent length ft.
Maximum vent length ft.
Maximum vent length ft.
(4” diameter)
(4” diameter)
(4” diameter)
(4” diameter)
Maximum Fresh air
Maximum Fresh air
Maximum Fresh air
Maximum Fresh air
intake length ft (4”
intake length ft (4”
intake length ft (4”
intake length ft (4”
diameter)
diameter)
diameter)
diameter)
Max. combination of
Max. combination of
Max. combination of
Max. combination of
fre
fre
fre
fresh air and vent ft.
sh air and vent ft.
sh air and vent ft.
sh air and vent ft.
(4” diameter)
(4” diameter)
(4” diameter)
(4” diameter)
SPS/U 40
10
45
50
75
SPS/U 40
20
45
50
75
SPS/U 50
20
45
50
75
SPS/U 50
30
35
40
65
SPS/U 50
40
25
30
55
SPS/U 75
20
45
50
75
SPS/U 75
30
35
40
65
SPS/U 75
40
25
30
55
SPS/U 100
30
45
50
75
SPS/U 100
40
35
40
65
SPS/U 100
50
25
30
55
SPS/U 125
30
60
50
75
SPS/U 125
40
50
40
65
SPS/U 125
50
40
30
55
SPS/U 125
60
30
20
45
SPS/U 150
40
60
50
75
SPS/U 150
50
50
40
65
SPS/U 150
60
40
30
55