![SunStar SC18M Installation Instructions Manual Download Page 7](http://html.mh-extra.com/html/sunstar/sc18m/sc18m_installation-instructions-manual_1400277007.webp)
Form
#43127350
-7-
July 09
12. Replace the heater cover.
STEP 1. Insert tabs along the top edge of the cover into the slots.
STEP 2. Rotate the cover down.
STEP 3. Insert the tabs on both sides of the heater into the lower slots.
STEP 4. Attach the cover with the original screws.
FAN CONTROL – Manual (on/off)
To operate the fan, plug the power cord into a 120-Volt outlet and turn the switch to the
“On” position.
See diagram of operating sequence below.
LIGHTING INSTRUCTIONS
1.
St
op!
Read
the
safety
information
above.
2.
Set
the
thermost
at
(gas
control
knob)
clockwise to OFF position.
3.
Tu
rn
off
all
electric
power
to
the
appliance.
4.
W
ait
ten
(10)
minutes
to
clear
out
any
gas.
Then
smell
for
gas
near
the
heater
and
at
the
floor
beneath
the
heater
. If
you
smell
gas
ST
OP!
Follow
B
in
the
safety
information
above.
If
you
do
not
smell
gas, go to the next step.
5.
Tu
rn
knob
on
gas
control
counterclockwise
to
P
PILOT
. Push
in
control
knob
to stop and hold.
6.
Repeatedly
push
the
piezo
ignitor
button
until
the
pilot
is
lit
(a
match
can
also
be
used
to
light
pilot
buner).
Continue
to
hold
the
control
knob
in
for
about
10
to
15
seconds
af
ter
the
pilot
is
lit.
Release
knob
and
it should
pop
back
up.
Pilot
burner
should
remain
lit.
If
it
goes
out
repeat
procedure 6.
If
knob
does
NOT
p
op
up
when
released
ST
OP!
turn
off
gas
supply
and
immediately
call
your
service
technician
or
gas
supplier
.
If the
pilot
will
not
stay
lit
after
several
tries,
turn the gas control clockwise
to
OFF
and
call
your
service
technician
or gas supplier
.
7.
When
the
pilot
burner
remains
lit
turn
the
gas control knob counterclockwise
to HI (high) position.
8.
Turn
on
all
electric
power
to
the
appliance.
9.
Thermost
at
(gas
control
knob)
can
be
set
to
desired setting from HI to LO.
10
.A
TTENTION:
Gas
control
has
an
interlock
latching
device.
When
the
pilot
burner
remains
lit
a safety
magnet
is
energized
and
the
interlock
latching
device
becomes
operative.
If the
gas
control
is
turned
to
the
OFF
position
or
gas
flow
to
the
appliance
is
shut
off
DO
NOT
RELIGHT
THE
PILOT
BURNER
until
the
safety
magnet
is
de-
energized
(approximately
60
seconds).
There
will
be
an
audible
click
when
the
safety magnet in the control is de-energized.
Pilot
burner
can
now
be
relit
by
repeating
step
s 3 thru 6 above.
HI
P
OFF
LO
Ignitor
Piezo
Electrode
Pilot Burner
Thermocouple
Pilot is located in the center below the glass front
HI
P
OFF
LO
Ignitor
Piezo
TO
TURN OFF GAS
TO
APPLIANCE
Turn the thermost
at (gas control knob)
clockwise
to the OFF position.
Do
not
use
excessive
force
when
turning
knob.
Turn
off
all
electric
power
to
the
appliance.
Step 1
Step 3 Step 4
Step 2
T0 T1 T2
T3
T4
T5
Ignition
Gas valve
Manual Ignition
Heater thermostat ON
Gas Valve OPEN
Manual Switch ON
Blower ON
Pilot Flame
Thermostat (heater)
Manual Switch (fan)
Blower
Heater Thermostat OFF
Gas Valve CLOSE
Manual Switch OFF
Blower OFF
Legend:
Function ON:
Function OFF: