SunStar SC10T-1-LP Installation And Owner'S Manual Download Page 12

-11- 

 

OPTIONAL FLOOR STAND 

INSTALLATION INSTRUCTIONS 

 

Install the optional floor stand as follows: 
 

1.

 

Remove the four (4) screws located on the base of the heater. 

2.

 

Align the clearance holes on the floor stand with the screw holes in the bottom of the heater as 
shown below. 

3.

 

Attach the base to the heater so that the solid portion of the base is facing towards the front of 
the heater using four (4) No 10 x 1” screws provided. 

4.

 

Attach a field supplied pipe elbow (3/8” NPT thread) to the bottom of the heater for connection 
to the gas line as shown in the figure below and as instructed previously in these instructions. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

WARNING: This heater must be installed on a wall whenever it is installed in a 
bedroom. 

The optional floor stand is available from Sunstar Heating Products Inc. or through your dealer.

Summary of Contents for SC10T-1-LP

Page 1: ...ance CONSUMER Retain this manual for future reference This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to the section titled Combustion and ventilation air requirement This appliance may be installed in an aftermarket permanently located manufactured mobile home where not pro...

Page 2: ...t install this heater at altitudes above 5000 ft because shutdown of the heater by the ODS system may occur due to reduced oxygen levels at these altitudes 5 This appliance is only for use with the type of gas indicated on the nameplate THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES Please check the gas type shown on the heater nameplate prior to hooking the heater to the gas supply 6 ...

Page 3: ...tu hr of gas consumption for the total input rating of all gas equipment in the space 18 This heater shall not be installed in a room or space unless the required volume of indoor combustion air is provided by the method described in the National Fuel Gas Code ANSI Z223 1 NFPA 54 the International Fuel Gas Code or applicable codes 19 WARNING If the area in which the heater may be operated does not...

Page 4: ..._ x 20 Btu hr ____________________ Btu hr STEP 3 Add the Btu hr inputs of all fuel burning appliances in this space NOTE DO NOT include Direct Vent gas appliances because these have sealed combustion systems that draw combustion air from outdoors Examples of appliances to consider include gas ranges gas water heaters gas logs kerosene heaters etc Proposed Vent Free Heater _________________________...

Page 5: ... odorant in escaped gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air there may be more odor at lower levels Always be sensitive to the slightest gas odor If ...

Page 6: ...hen facing the front of the heater the clearance from any combustible materials must be a minimum of 10 from the left 10 from the right 36 from the top and 2 from the bottom Never install the heater in front of any flammable object especially do not place curtains furniture clothing or other flammable objects less than 36 from the front of the heater FLOOR MOUNT INSTALLATION This heater is designe...

Page 7: ...according to the dimensions shown on the upper corner of Figure 2 1 3 Drill another 5 16 hole on the wall stud for the lower mounting point 4 Screw in the three 3 plastic expansion anchors furnished with the unit as shown in Figure 2 1 5 Screw in the furnished screws to the anchors for the upper mounting points and hang the heater on the screws as shown in Figure 2 1 6 Fasten the bottom of the hea...

Page 8: ... gas supply line shall be sized and installed to provide a sufficient supply of gas to meet the minimum demand of the heater without undue loss of pressure Typical Installation Supply Line Up to 20 000 Btu hr 3 8 or greater Up to 30 000 Btu hr 1 2 or greater 5 The sealant used on the threaded pipe joints of the gas pipe must be the specific type resistant to the action of Liquid Petroleum Gas Appl...

Page 9: ...ating season If your pilot will not stay lit try cleaning it Use a can of compressed air such as is used to clean a computer to blow dust out of the pilot assembly Sometimes just blowing air back through the pilot will get rid of the dirt If that fails to solve the problem remove the wire clip that holds the metal strip onto the pilot assembly Remove the cover and blow any dust out Reassemble and ...

Page 10: ... and it will pop back up Pilot should remain Iit If it goes out repeat steps 3 through 7 If knob does not pop up when released stop and inmediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to the OFF position and call your service technician or gas supplier 8 Attention Gas control has an INTERLOCK device When the pilo...

Page 11: ...gas valve BURNER DOES NOT LIGHT Pilot stays lit Burner orifice clogged Burner orifices not correct size Extremely low inlet gas pressure Gas valve is defective Clean or replace orifices Replace with correct size Contact gas supplier Replace gas valve IMPROPER BURNER PATTERN Slight smoke or odor during initial operation Residues from manufacturing process or dust Problem will be eliminated after a ...

Page 12: ...ater so that the solid portion of the base is facing towards the front of the heater using four 4 No 10 x 1 screws provided 4 Attach a field supplied pipe elbow 3 8 NPT thread to the bottom of the heater for connection to the gas line as shown in the figure below and as instructed previously in these instructions WARNING This heater must be installed on a wall whenever it is installed in a bedroom...

Page 13: ... the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury REPAIR PARTS LIST MODELS SC10T 1 LP Propane Gas SC10T 1 NG Natural Gas ...

Page 14: ...LS SC10T 1 LP Propane Gas SC10T 1 NG Natural Gas WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury ...

Page 15: ...590050 Connector 10 43596010 43596010 Control Valve 11 43590050 43590050 Connector 12 43585830 43585830 Tubing Regulator to Tap 13 43585850 43585850 Tubing Valve to Distributor T 14 43585880 Tubing Valve to Pilot 15 43591010 43591010 Distributor T 16 43585840 43585840 Tubing Distributor T to First Setting 17 43585840 43585840 Tubing Distributor T to First Setting 18 43601070 43601070 Shoulder Ther...

Page 16: ...15 Manufactured for SUNSTAR HEATING PRODUCTS INC 306 West Tremont Avenue Charlotte NC 28203 4946 704 372 3486 ...