background image

 

SIM800 Series_Multiplexer_Application Note_V1.04 

www.simcom.com      

                                                               

2 / 25                          

 

 

 

Document Title: 

SIM800 Series_Multiplexer_Application Note   

Version: 

1.04 

Date: 

2020.06.15 

Status: 

Released 

 

 

GENERAL NOTES 

 

SIMCOM OFFERS THIS INFORMATION AS A SERVICE TO ITS CUSTOMERS, TO SUPPORT 

APPLICATION AND ENGINEERING EFFORTS THAT USE THE PRODUCTS DESIGNED BY SIMCOM. 

THE INFORMATION PROVIDED IS BASED UPON REQUIREMENTS SPECIFICALLY PROVIDED TO 

SIMCOM BY THE CUSTOMERS. SIMCOM HAS NOT UNDERTAKEN ANY INDEPENDENT SEARCH 

FOR ADDITIONAL RELEVANT INFORMATION, INCLUDING ANY INFORMATION THAT MAY BE IN THE 

CUSTOMER’S POSSESSION. FURTHERMORE, SYSTEM VALIDATION OF THIS PRODUCT 

DESIGNED BY SIMCOM WITHIN A LARGER ELECTRONIC SYSTEM REMAINS THE RESPONSIBILITY 

OF THE CUSTOMER OR THE CUSTOMER’S SYSTEM INTEGRATOR. ALL SPECIFICATIONS 

SUPPLIED HEREIN ARE SUBJECT TO CHANGE. 

 

 

COPYRIGHT 
 

THIS DOCUMENT CONTAINS PROPRIETARY TECHNICAL INFORMATION WHICH IS THE PROPERTY 

OF SIMCOM WIRELESS SOLUTIONS LIMITED COPYING, TO OTHERS AND USING THIS DOCUMENT, 

ARE FORBIDDEN WITHOUT EXPRESS AUTHORITY BY SIMCOM. OFFENDERS ARE LIABLE TO THE 

PAYMENT OF INDEMNIFICATIONS. ALL RIGHTS RESERVED    BY SIMCOM IN THE PROPRIETARY 

TECHNICAL INFORMATION 

INCLUDING BUT NOT LIMITED TO REGISTRATION GRANTING OF A 

PATENT , A UTILITY MODEL OR DESIGN. ALL SPECIFICATION SUPPLIED HEREIN ARE SUBJECT TO 

CHANGE WITHOUT NOTICE AT ANY TIME. 

 

 

SIMCom Wireless Solutions Limited

 

Building B, SIM Technology Building, No.633 Jinzhong Road, Changning District, Shanghai P.R. China 

Tel: +86 21 31575100 

Email: 

[email protected]

 

 

For more information, please visit:

 

https://www.simcom.com/download/list-863-en.html

 

 

For technical support, or to report documentation errors, please visit:

 

https://www.simcom.com/ask/ or email to: 

[email protected]

 

 

 

Copyright © 2020 SIMCom Wireless Solutions Limited All Rights Reserved.

 

 

Summary of Contents for SIMCom SIM800 Series

Page 1: ...iplexer _Application Note SIMCom Wireless Solutions Limited Building B SIM Technology Building No 633 Jinzhong Road Changning District Shanghai P R China Tel 86 21 31575100 support simcom com www simc...

Page 2: ...HEREIN ARE SUBJECT TO CHANGE COPYRIGHT THIS DOCUMENT CONTAINS PROPRIETARY TECHNICAL INFORMATION WHICH IS THE PROPERTY OF SIMCOM WIRELESS SOLUTIONS LIMITED COPYING TO OTHERS AND USING THIS DOCUMENT AR...

Page 3: ...06 30 Haibing chen Chapter Scope Add projects Chapter 2 6 Add note 1 02 2016 11 17 Wenjie lai Scope 1 03 2019 08 12 Yulong zheng Modify format of UA frame 1 04 2020 06 15 Yizhe Tan Wenjie Lai Change...

Page 4: ...iagram 8 2 3 Restrictions 9 3 SIMCOM Multiplexer Protocol 10 3 1 Transmission Frame Structures 10 3 1 1 Opening and Closing Flag Field 10 3 1 2 Address Flag Field 10 3 1 3 Address Flag Field 11 3 1 4...

Page 5: ...8 About Flow Control 17 3 9 Samples for Frame Structure 18 3 10 Transmission Bit Sequence 19 4 MUX Examples 20 4 1 Establish Channels 20 4 2 Frame Transmission 22 4 3 Power Saving Mode and Wake Up 22...

Page 6: ...t 1 2 Related documents 1 SIM800 Series AT Command Manual 2 Digital cellular telecommunications system Phase 2 3 Terminal Equipment to Mobile Station TE MS multiplexer protocol GSM 07 10 version 7 1 0...

Page 7: ...mand TE Terminal Equipment MS Mobile Station FC Flow Control RTC Ready To Communicate RTR Ready To Receive IC Incoming Call Indicator DV Data Valid PN Parameter Negotiation FCon Flow Control On Comman...

Page 8: ...n multiplexer device it is so inefficient to deal with only one kind or one channel of data steam during a period of time Therefore SIMCom multiplexer is designed with GSM0710 standard to separate tra...

Page 9: ...efined in GSM 0710 are set to default as following table Parameter Value Comment T1 Acknowledgement Timer 100 milliseconds Time that a station will wait for an acknowledgement before resorting to othe...

Page 10: ...Length Field Information Field FCS Field Closing Flag 1 byte 1 byte 1 byte 2 byte Multi byte 1 byte 1 byte 3 1 1 Opening and Closing Flag Field Each frame begins and ends with a flag sequence octet w...

Page 11: ...1 1 P F 0 0 0 0x0F DM Disconnected Mode 1 1 0 0 P F 0 1 0 0x43 DISC Disconnect 1 1 1 1 P F 1 1 1 0xEF UIH Unnumbered Information with Header check 1 1 0 0 P F 0 0 0 0x03 UI Unnumbered Information Not...

Page 12: ...t structured The information field is only present in UIH frames 3 2 Frame Type 3 2 1 SABM SABM is command frame and shall be used to establish DLC between TE and MS Please refer to 3 1 for more detai...

Page 13: ...connected mode is terminated by the receipt of a SABM command If a DISC command is received while in disconnected mode a DM response should be sent Please refer to 3 1 for more details 3 2 5 UIH The U...

Page 14: ...nnel established at the initiation of the multiplexer between the TE and MS and it has the DLCI value 0 UIH message frame is transmitted through control channel All UIH message frame conform to the fo...

Page 15: ...EA C R 0 0 0 0 1 1 Hex value is 0xC3 Command 0xC1 Response The EA bit is always set the 1 The length field in CLD message frame is 0 It has no value octet 3 6 3 Test Message type coding octet 1 2 3 4...

Page 16: ...1 The C R bit is used to indicate if it is a Modem Status Command or Modem Status Response In a Modem Status Command it is the status of the sender s own V 24 signals that shall be sent but in a Resp...

Page 17: ...D data streams Data channels shall be established after and only after control channel DLCI 0 connected Please refer to 3 1 for more details If the customer wants to transmit large data streams such a...

Page 18: ...FCon response The difference between MSC and Fcon Fcoff is that the former only flow controls one of the data channels and the latter controls all the data channels except controls channel Please ref...

Page 19: ...SIM800 Series_Multiplexer_Application Note_V1 04 www simcom com 19 25 3 10Transmission Bit Sequence Transmission is based on 1 start bit 8 data bits 1 stop bit and no parity...

Page 20: ...MS feed back response 61 74 2B 63 6D 75 78 3D 30 0D 0D 0A 4F 4B 0D 0A 0D 0A AT CMUX 0 CR LF O K CR LF CR LF Host need quickly send the establish DLC0 frame otherwise the client will exit MUX state St...

Page 21: ...response SABM 1 If MS responses DM frame to TE it means establish DLCI failed 2 If MS responses UA frame to TE it means establish DLCI successful For SIM800 series when MS responses UA frame to TE th...

Page 22: ...54 49 0D 58 F9 UIH Frame MS feeds back through DLC 1 F9 07 EF 09 41 54 49 0d 3F F9 F9 07 EF 21 0D 0A 53 49 4D 39 30 30 20 52 31 31 2E 30 0D 0A FF F9 F9 07 EF 0D 0D 0A 4F 4B 0D 0A 4A F9 UIH Frame 2 TE...

Page 23: ...nything on DLC 1 F9 01 EF 0B E3 07 07 8F 01 79 F9 2 MS sends MSC message with FC bit set to 0 through control channel DLC 0 to indicate recovery of DLC 1 data transmission F9 01 EF 0B E3 07 07 8D 01 7...

Page 24: ...mal F9 07 EF 07 41 54 0D 67 F9 F9 07 EF 0D 0D 0A 4F 4B 0D 0A 8A F9 Sending illegal hex byte will lead MS to receive a wrong frame When receiving illegal hex byte between frames MS will just throw it a...

Page 25: ...UA frame to accept F9 0F 73 01 50 F9 4 TE sends DISC frame to request closing down DLC 4 F9 13 53 01 3f F9 MS feeds back UA frame to accept F9 13 73 01 5D F9 5 TE sends CLD message frame to request cl...

Reviews: