Install the mobile dehumidifier on a flat surface, in a spacious location where the air outlets
will not be covered up or blocked. Do not install underneath desks or inside closets where the
airflow is limited.  Make sure there are no debris falling on top of the unit.

For a maximum efficiency of the dehu-
midifier, keep a clearance of at least
20 cm front and on top of the unit
(keep 20 cm at the back of the unit in
continuous dehumidifying mode).

TECHNICAL SPECIFICATIONS 

Models

Power supply

115 V / 1 phase / 60 Hz

Wattage / amperage

490 W / 4.5 A

560 W / 5.2 A

610 W / 5.9 A

800 W / 7.2 A

Maximum surface

186 m

2

232 m

2

279 m

2

325 m

2

(according to conditions)

(2,000 ft

2

) max. (2,500 ft

2

) max. (3,000 ft

2

) max.

(3,500 ft

2

) max. 

Tank capacity

5.7 L (1.5 gal.)

5.7 L (1.5 gal.)

11 L (2.9 gal.)

11 L (2.9 gal.)

Operating temperature

13 - 35°C (55 - 95°F)

Humidity adjustment range

35% - 80%

Dehumidifying capacity

14L / day (30 pints / day) 19L/day(40 pints/day)

24L/day(50 pints/day)

31L/day(65 pints/day)

Net weight (empty)

14.7 kg (32.4 lbs)15.2 kg (33.5 lbs)

20 kg (44 lbs)

20.6 kg (45.4 lbs)

Net weight (full)

20 kg (44 lbs)

20 kg (44 lbs) 28.8 kg (63.5 lbs) 29.2 kg (64.3 lbs)

Product size (W x D x H)                      50 x 33.4 x 26 cm

62.2 x 38.5 x 32.1 cm

(19.7” x 13.2” x 10.2”)

(24.5” x 15.2” x12.7”)

14 L 

19 L

24 L

31 L

20 cm

20

cm

Summary of Contents for 14 L

Page 1: ...d utiliser ce déshumidificateur veuillez lire attentivement ce guide d utilisation Conservez le avec votre preuve d achat pour référence future si nécessaire MODÈLES 14 L 19 L 24 L 31 L 00210 26 11 06 Tous droits réservés Sunrise Tradex Corp 2006 ...

Page 2: ...2 TABLE OF CONTENTS USE 3 SAFETY NOTES 3 PARTS IDENTIFICATION 4 CONTROL PANEL 4 TECHNICAL SPECIFICATIONS 5 INSTALLATION 5 OPERATION 6 7 MAINTENANCE 8 TROUBLESHOOTING 9 WARRANTY 10 ...

Page 3: ...the dehumidifier in the following areas Next to any source of heat such as a radiator an heater a tumble dryer etc In an area exposed to direct sunlight Near a bath a shower enclosure or a swimming pool In areas where oil or water are likely to splash In a greenhouse 5 Never insert fingers or other foreign objects into grills or openings Always warn children of these dangers 6 Always store the uni...

Page 4: ... the fan speed is high NORMAL pilot light 11 low fan speed is on and the fan speed is low I O light this pilot light flashes when the unit is turned on The light is permanently on no flashing when the unit is running and it goes out when the dehumidifier is turned off CONTINUE pilot light it is on when the unit is on dehumidifying mode FULL pilot light it is on when the water tank is full the dehu...

Page 5: ... Wattage amperage 490 W 4 5 A 560 W 5 2 A 610 W 5 9 A 800 W 7 2 A Maximum surface 186 m2 232 m2 279 m2 325 m2 according to conditions 2 000 ft2 max 2 500 ft2 max 3 000 ft2 max 3 500 ft2 max Tank capacity 5 7 L 1 5 gal 5 7 L 1 5 gal 11 L 2 9 gal 11 L 2 9 gal Operating temperature 13 35 C 55 95 F Humidity adjustment range 35 80 Dehumidifying capacity 14L day 30 pints day 19L day 40 pints day 24L day...

Page 6: ...ectrical outlet Plug the unit into a 115V 60Hz grounded outlet Make sure the water tank is correctly positioned otherwise the unit will not operate properly TURNING THE UNIT ON or OFF 1 Plug the power cord into an electrical outlet of proper rating The dehumidifier s computer system will perform a self check If everything is normal the I O pilot light flashes Push on the button the unit starts run...

Page 7: ...r tank is put back into the unit CONTINUOUS DRAINAGE Remove the plastic cover on the back of the unit and fix the threaded hose coupling provided with the unit as shown on picture below Remove the water tank and slide the 6 hose provided with the unit onto the connector located inside the unit The hose should slide on smoothly without bending or kinking For the external drain take a hose of the ri...

Page 8: ...animals or if the unit is installed in a dusty area AIR FILTER REMOVAL Pull the air filter out as shown in Figure A AIR FILTER CLEANIING Clean the air filter using clear and lukewarm water let it dry completely and put the filter back as shown in Figure C UNIT ENCLOSURE Use a soft and clean cloth to wipe the surface Do not use water to prevent from shock hazard and damaging the unit WATER TANK Cle...

Page 9: ...tion in dehumidifying mode Unit is less efficient Air filter is blocked Clean the air filter Room windows and doors are Close windows and doors opened An object is blocking the air Remove the object outlet or inlet Noisy unit Unstable installation of the unit Reposition the unit levelling it on a flat surface Air filter is blocked Clean the air filter Screen shows P2 The tank is full or not Empty ...

Page 10: ...he unit enclosure or to other outer features caused by wear 4 The filter 5 Damage caused by repairs or modifications to the humidifier made by any person not duly authorized by SUNRISE TRADEX CORP 6 Insurance and freight costs for the warranty service ALL IMPLIED WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY ARE LIMITED TO A TWO YEAR 2 PERIOD COVERED BY THIS EXPRESS LIMITED WARRAN T...

Reviews: