UNIT OPERATION

• Plug the power cord into a properly rated grounded outlet. Do not connect the unit to an 

outlet that is being used by other electrical appliances.

• Then press the       I/O button to begin operation.
• When starting the air conditioner, always set the unit to COOL and the temperature to the 

coolest degree - 16

o

C (61

o

F).  Let it run with for 2 hours.

• When the desired room confort level is reached, adjust the fan speed to maintain this 

temperature and adjust temperature accordingly if necessary.

• Since the air conditioner takes few hours to cool off the room, it is recommended to let the 

air conditioner work 24/24 h. and adjust the temperature instead of stopping and starting
the air conditioner on a daily basis.

• If the unit is turned off while running in COOL, DRY or AUTO mode, when turning the unit 

back on, allow 3 minutes before the compressor resumes. 

COOLING

1.

Press the MODE      button and set until the COOLING icon         lights up.

2.

The display will show the set temperature. Press on the temperature button      to set the 

temperature - 16

o

C to 31

o

C (61

o

F to 88

o

F).

3.

Press FAN SPEED     to set fan speed at LOW, MEDIUM or HIGH ; each speed level is 

identified by an icon lighting up when selected        .

• When the room temperature is slightly warmer than the set temperature, the compressor 

starts running and the air conditioner cools the room off. When the room temperature is 
slightly colder, the compressor stops, but the fan keeps on running.

• The exhaust hose must be correctly installed and that the air inlet and outlet grilles must be 

cleared out.

• Make sure that the drain hose and cap are correctly installed.
• For maximum efficiency, draw the curtains or blinds if the room is exposed to direct sunlight.
• Do not place near a heat source.

DEHUMIDIFYING

P

RESS THE

MODE       

BUTTON UNTIL THE

DEHUMIDIFYING

ICON

LIGHTS UP

.

• The exhaust hose must be correctly installed.
• In dehumidifying mode, the fan runs at low speed and speed cannot be changed.
• Make sure that the drain hose and cap are correctly installed.
• The unit will not operate if the room temperature is lower than 16

o

C (61

o

F).

• For maximum dehumidifying efficiency, keep windows and doors closed.

FAN
1.

Press the MODE      button and set until the FAN icon       lights up.

2.

Press FAN SPEED     to set fan speed at LOW, MEDIUM or HIGH ; each speed level is 

identified by an icon lighting up when selected        .

• In FAN mode, the exhaust hose is inoperative.

Summary of Contents for Fellini 13-04540

Page 1: ...NDITIONER Before using this air conditioner please read the following instructions carefully and keep this manual along with your proof of purchase in a safe place for future reference l MODEL 13 04540 13 04553 KY 32U D 00193 12 01 06 Copyright Sunrise Tradex Corp 2005 ...

Page 2: ...se 6 Wall installation 6 Installation by window type 7 CONTROL PANEL AND LCD DISPLAY Control panel 8 LCD display 8 UNIT OPERATION Cooling 9 Dehumidifying 9 Fan 9 Auto Mode 10 Sleep Mode 10 Setting the timer 10 REMOTE CONTROL 11 12 13 WATER DRAINAGE 14 MAINTENANCE Cleaning the housing 15 Cleaning the filter 15 Storage 15 TROUBLESHOOTING CHART 16 TECHNICAL SPECIFICATIONS 17 CUSTOMER SERVICE 17 WARRA...

Page 3: ...install or use the unit in the following places near a heat source an area with possible gas leakage or in an explosive atmosphere near a bath shower enclosure swimming pool or any other steamy and wet areas in a greenhouse 6 Do not apply insecticides or any other flammable products on the unit 7 Do not start or stop the unit by plugging in or pulling out the power cord 8 Do not operate with wet h...

Page 4: ...lectric cord hot air outlet upper air outlet handle lower air inlet grille control panel lower air inlet grille water drain hole INSTALLATION KIT hose square adaptor to unit air exhaust hose window adjustable slider kit hose oval adaptor to window 4 ...

Page 5: ...delay fuse or circuit breaker 5 If the power cord or plug is damaged call SUNRISE TRADEX Customer Service Electrical ratings of the air conditioner are detailed on the rating plate on the back of the unit Basic electrical requirements are listed hereafter Please make sure to check the following before installing and connecting your unit INSTALLATION 5 Casters Drain hose Cap Clamp Rear grille PREPA...

Page 6: ...le to correctly install the air conditioner and the hot air outlet 2 Drill a hole of 13 3 cm 5 1 4 on the exterior wall The hole must be 40 to 130 cm 16 tp 50 above the floor figures C 3 Fix the external end of the exhaust hose onto the wall pre drilled hole NOTE The hot air exhaust hose must be as short as possible To avoid hot air backdraft and guarantee an efficient exhausting of the hot air ma...

Page 7: ...the window onto the window kit to form a tight seal 3 Attach the exhaust hose adaptor to the window slider kit the adaptor tabs will lock into place the adaptor to the window kit INSTALLATION 7 NOTE Using the window slider kit may make it difficult to correctly close and or lock the window Additional safety precautions should be considered Make sure to correctly install and insulate the window sli...

Page 8: ...r auto mode To set the time of hours when the timer is on Sets the air conditioner in SLEEP mode automatic shut off LCD screen display SLEEP In sleep mode automatic shut off COOL In cooling mode FAN In fan only mode DRY In dehumidifying mode SET TEMP Displays the set temperature AUTO Auto mode Fan speeds LOW MEDIUM HIGH SET TIME Displays the hours set when timer is on ON Timer is on OFF Timer is o...

Page 9: ...D to set fan speed at LOW MEDIUM or HIGH each speed level is identified by an icon lighting up when selected When the room temperature is slightly warmer than the set temperature the compressor starts running and the air conditioner cools the room off When the room temperature is slightly colder the compressor stops but the fan keeps on running The exhaust hose must be correctly installed and that...

Page 10: ...off in less than 7 hours use the TIMER button to adjust the delay by 1 2 hour slot up to 7 hours maximum The LCD display will show the set time 5 To cancel press again the SLEEP button until the SLEEP icon goes off When the SLEEP mode is on you can still modify program any other function on the unit You cannot set the TIMER ON for an automatic shut off if the unit is in SLEEP mode The SLEEP mode c...

Page 11: ... may need to control your air conditioner from a distance All operational functions of your remote as well as message and icon identification are described in the next 2 pages After entering a mode or function on your remote always press on SEND to initiate the command on the unit You will hear a beep from the unit meaning that the function has been received and initiated When keying a function or...

Page 12: ... on FAN and choose the speed HIGH M Medium or LOW each speed icon will flash Press on SEND a beep will confirm transmission and the speed icon will stop flashing TO SET TEMPERATURE Press on oC or oC to set the desired température the temperature icon will flash The temperature is increased or decreased by 1o each time you press on these buttons The temperature settings range from 16oC to 30oC 61oF...

Page 13: ...IME CLOCK Press on TIMER until the TIME icon flashes the LCD screen will display the current time To change the time press on Hr the hour icon will flash set the hour then press on Min to set the minutes the minute icon starts flashing and the hour icon stops flashing set the minutes then press on SEND the minute icon will stop flashing IMPORTANT always check and set the clock at the right time be...

Page 14: ...ge meaning that the tank is full and the unit will stop running To resume operation empty the water tank as per the following 1 Turn the unit off Do not move the unit when the water pan is full 2 Unclamp the drain hose from the rear grille 3 Place a 2L container under the drain hose 4 Remove the cap from the drain hose The condensate water will drain out automatically When the 2L container is full...

Page 15: ...ere are animals around If the filter is damaged or used contact SUNRISE TRADEX Customer Service STORAGE Turn the unit off and unplug Drain all condensate water from the unit Turn the unit to fan mode for a couple of hours to completely dry out the inside Clean the filter Wind the power cord to the hangers Always store the unit upright in a clean and dry aera It is recommended to store the unit in ...

Page 16: ...it is not working properly The water tank is full Is the air filter dirty Is the air conditioner leveled Is the drain hose and the hose cap correctly installed SOLUTION 1 Plug in correctly 2 Change the plug or receptacle Cancel the timer or wait for the unit to start 1 Increase the humidity level 2 The unit is defrosting it will resume after the defrosting cycle is completed 3 Clean or change the ...

Page 17: ...g Model KY 32U D Cooling capacity 1 12000 BTU H Dehumidifying capacity 53L 14 Gal day Power Cooling 1200 W Watts Dehumidifying 1200 W Air flow volume cubic metre h 2 330 M3 h Power source 115V 60Hz Noise level 3 56 dB A Net Weight Gross Weight 43 Kg 95 lb 45 Kg 99 lb Unit 86 H x 45 W x 37 D cm 34 H x 18 W x 15 D Package 113 H x 54 W x 49 D cm 44 H x 21 W x 19 D Refrigerant R22 Water tank capacity ...

Page 18: ...nclosure or to other outer features caused by wear 4 The filter 5 Damage caused by repairs or modifications to the air conditioner made by any person not duly authorized by SUNRISE TRADEX CORP 6 Insurance and freight costs for the warranty service ALL IMPLIED WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY ARE LIMITED TO A TWO YEAR 2 PERIOD COVERED BY THIS EXPRESS LIMITED WARRANTY SUN...

Reviews: