RFC2544/NE Testing
RFC2544 Summary Results
View the overall RFC2544 results, including a Status report, such as "Pass” or "Fail"
NE test results include the throughput status for each frame rate, with "Pass” or
"Fail" result.
For Throughput, the "Pass/Fail” message is an indication of whether or not any
frames were lost during the test. This has no bearing on the Thresholds set in the
configuration.
Left Side Results Table
Statistic Meaning
Seq#
Sequence number denoting the order and repetitions of the tests.
Test
Type of test.
Size
Frame size under test.
Rate
The throughput rate currently being tested is reported, in
percentage of bandwidth.
Frames
Number of frames tested. Applies to Back-to-Back frames test.
Status
Test status; pass/fail, percentage of frames lost.
Status
Statistic Meaning
RT
Remaining Time for the test in progress. Once the test is
completed, the results of the test will be indicated.
TX
Utilization
Transmitted percentage bandwidth utilization
TX Line
Rate
Transmitted data rate (in kbps, bps, etc.).
TX Data
Rate
Transmit data rate (in kbps, bps, etc.).
RX
Utilization
Received percentage bandwidth utilization.
RX Line
Rate
Receive data rate (in kbps, bps, etc.).
RX Data
Rate
Receive data rate (in kbps, bps, etc.).
Signal
The signal information for optical interfaces (vendor, wavelength, optical power, etc.)
is provided by the SFP module. Not all manufacturers supply this information, and
Sunrise Telecom Inc. is not responsible for modules provided by other vendors.
•
Vendor
: Name of the vendor;
•
Wavelength
: Optical wavelength is use at the port.
•
RX Optical Power
: Received uW and dBm.
Where do you want to go next?
101
Summary of Contents for XTT 5000
Page 1: ...XTT 5000 User s Manual...
Page 2: ......
Page 6: ......
Page 36: ......
Page 55: ...Throughput Testing L2 BERT Diagram Home Layer 2 BERT Where do you want to go next Home 49...
Page 58: ...XTT 5000 User s Manual Throughput Stream Results Throughput Test Setup Working Desktop Home 52...
Page 61: ...Throughput Testing Home 55...
Page 67: ...Throughput Testing Throughput Aggregate Results Throughput Stream Results Home 61...
Page 81: ...Throughput Testing Working Desktop Home 75...
Page 83: ...Throughput Testing Home 77...
Page 116: ......
Page 142: ......
Page 147: ...Save Features 141 RFC2544 NE Applications IP Test Setup Monitor Setup Loopback Test Setup Home...
Page 148: ......
Page 172: ......