Sunrise Medical Quickie Z-500 User Instruction Manual & Warranty Download Page 6

930578 Rev. B

V .   E M I   ( E l e c t r o m a g n e t i c   I n t e r f e r e n c e )

11

•Buddy Button
•Micro Light
•Star Board
•Wafer Board
•Penta Switch
•Plate Switch
•Soft  Switch
•Grasp Switch
•Wobble Switch

Individuals with physical limitations requiring the use of a specialty control
input device known not to be immune to 20V/m, or not known, should exer-
cise extra care around known sources of EMI.

There is no way to know the effect on EMI if you add accessories or modify
this chair. Any change to your chair may increase the risk of EMI. Parts from
other suppliers have unknown EMI properties.

F. REPORT ALL SUSPECTED EMI INCIDENTS

You should promptly report any unintended movement or brake release. 
Be sure to indicate whether there was a radio wave source near your chair 
at the time. Contact: Customer Service Department at (800) 333-4000. 

V .   E M I   ( E l e c t r o m a g n e t i c   I n t e r f e r e n c e )

930578 Rev. B

10

2. Medium-Range Mobile Transceivers: 

These include two-way radios used in police cars, fire trucks, ambulances and
taxi cabs. The antenna is usually mounted on the outside of the vehicle. 

3. Long-Range Transceivers: 

These include commercial radio and TV broadcast antenna towers 
and amateur (HAM) radios. 

NOTE– 

The following are not likely to cause EMI problems: Lap-top computers (without
phone or fax), Cordless phones, TV sets or AM/FM radios, CD or tape players.

D. DISTANCE FROM THE SOURCE

EM energy rapidly becomes more intense as you get closer to the source. 
For this reason, EMI from hand-held devices is of special concern. 

(See C.1 pg. 9)

A person using one of these devices can bring high 

levels of EM energy very close to your chair without you knowing it.

E. IMMUNITY LEVEL

1. The level of EM is measured in volts per meter (V/m). Every power wheelchair

can resist EMI up to a certain level. This is called its “immunity level”. 

2. The higher the immunity level, the less the risk of EMI. It is believed that a 

20 V/m immunity level will protect the power wheelchair user from the more
common sources of radio waves. 

3. The configuration tested and found to be immune to at least 20 V/m is:

Quickie Z-500 power wheelchair with a right-hand mounted QTRONIX remote joy-
stick system, single-post height-adjustable armrests, 90º hangers, 13” seat
width, 15” seat depth and 22NF gel cell batteries.

4. The following specialty input devices have an unknown effect on the immunity

level because they have not been tested with the Z-500:
•Breath Control
•Tri-Switch Head Array
•Heavy Duty Switched Joystick
•Treadle Switch
•Ribbon Switch
•Proximity Head Array
•Zero Touch Switch
•4-Zero Touch Switch
•5-Zero Touch Switch
•Disc Switch
•Proportional Head Control
•Proportional Mini-Joystick/Chin Control

Summary of Contents for Quickie Z-500

Page 1: ...uickie Z 500 User Instruction Manual Warranty SUPPLIER THIS MANUAL MUST BE GIVEN TO THE RIDER OF THIS WHEELCHAIR RIDER BEFORE USING THIS WHEELCHAIR READ THIS ENTIRE MANUAL AND SAVE FOR FUTURE REFERENC...

Page 2: ...tion about safety new products and options to increase your use and enjoyment of this wheelchair If you lose your war ranty card call or write and we will gladly send you a new one FOR ANSWERS TO YOUR...

Page 3: ...or Replace a Tire 46 G Motor Brushes 47 H Ordering Parts 47 I Maintenance Chart 47 XIII WIRING DIAGRAM 48 XIV SUNRISE LIMITED WARRANTY 49 I I T a b l e o f C o n t e n t s 930578 Rev B 4 I INTRODUCTIO...

Page 4: ...15 16 Upholstery color Options Standard black Option blue red hot pink Footrest Standard Swing away with composite footplates and heel loops Option articulating legrests elevat ing legrests angle adj...

Page 5: ...ax Other personal communication devices NOTE These devices can transmit signals while they are on even if not in use I V N o t i c e R e a d B e f o r e U s e 930578 Rev B 8 A CHOOSE THE RIGHT CHAIR S...

Page 6: ...ikely to cause EMI problems Lap top computers without phone or fax Cordless phones TV sets or AM FM radios CD or tape players D DISTANCE FROM THE SOURCE EM energy rapidly becomes more intense as you g...

Page 7: ...n g s 930578 Rev B 12 Heed all warnings in this section If you fail to do so a fall tip over or loss of control may occur and cause severe injury to your or others A NOTICE TO RIDER 1 Before using thi...

Page 8: ...e r a l W a r n i n g s 930578 Rev B 14 1 If you modify or adjust this chair it may increase the risk of a fall or tip over 2 Modifications unauthorized by Sunrise constitutes remanufacturing of the w...

Page 9: ...ft if you dress or change clothes while seated in this chair To make the chair more stable rotate the front casters until they are forward V I G e n e r a l W a r n i n g s 930578 Rev B 16 To Reduce T...

Page 10: ...ds are very dangerous Even a small change in height may stop a caster wheel and cause your chair to tip You may need to Remove or cover threshold strips between rooms Install a ramp at entry or exit d...

Page 11: ...roper design will vary depending on such things as the length and height of the ramp the need for an intermediate platform landing size doors and the direction of swing and whether the ramp includes a...

Page 12: ...prevent tire damage Use a hand pump or a low volume air pump to inflate tires Use a tire gauge to check pressure 5 Driving over sharp objects may cause damage to pneumatic tires and tubes V I I W a r...

Page 13: ...evice can help keep you from sliding down in the seat Consult your health care professional to find out if you need such a device 3 The belt must be snug but must not be so tight that it interferes wi...

Page 14: ...se a torque wrench NOTE The wrench must measure inch pounds You can buy a torque wrench and prop er sockets from a hardware store V I I I T i p s F o r A t t e n d a n t s 930578 Rev B 26 1 Persons wh...

Page 15: ...t m e n t U s e 930578 Rev B 28 CHECK OUT Be sure this chair performs to your chosen operational settings If it does not turn the chair off immediately and reprogram with the Quickie QTRONIX Programme...

Page 16: ...event wheel movement when in locked position c Adjust angle position d Tighten screws I X S e t U p A d j u s t m e n t U s e 930578 Rev B 30 D ELEVATING LEGREST OPTIONAL 1 Installation To install or...

Page 17: ...ower than the rear I X S e t U p A d j u s t m e n t U s e 930578 Rev B 32 J HEIGHT ADJUSTABLE ARMRESTS OPTIONAL 1 Installation a Slide the outer armpost into the receiver mount ed to the wheelchair f...

Page 18: ...vailable from your authorized supplier NOTE ON WIDTH ADJUSTMENT Size changes may require a larger seat insert and footplates 15 and 16 widths receive adult hangers P CHECK OUT After the wheelchair is...

Page 19: ...or locks 6 Joystick Boot F Make sure the boot is not torn or cracked this could allow debris water or moisture to enter If the boot is torn or cracked replace it as soon as you can 7 Remote Switch Jac...

Page 20: ...rical system may fail and result in severe injury to or death of rider B BATTERY CHARGER A battery charger produces a direct current DC When applied to a discharged battery this reverses the chemical...

Page 21: ...ttempt to repair it yourself Return charger to Sunrise or have repairs made only by a qualified person Keep cord out of the way where it will not be stepped on tripped over or damaged 3 Caution To Avo...

Page 22: ...put voltage is 110 volts 2 Never touch the charger after it is connected to an electrical outlet This may cause electrical shock Never connect or disconnect charger from battery while there is power t...

Page 23: ...d the useful life of your chair 2 Clean your chair regularly This will help you find loose or worn parts and will make your chair easier to use 3 To protect your investment have all major service and...

Page 24: ...y A n n u a l l y M o n t h l y W e e k l y D a i l y 3 CAUTION To prevent tire damage Use a hand pump or a low volume air pump to inflate tires Use a tire gauge to check pressure F TO REPAIR OR REPLA...

Page 25: ...s Ninety 90 days All other Original Components 3 LIMITATIONS a We do not warrant damage due to Neglect misuse or improper installation or repair Use of parts or changes not authorized by Sunrise Excee...

Page 26: ...Sunrise Medical Inc 7477 East Dry Creek Parkway Longmont Colorado 80503 USA 800 333 4000 In Canada 800 263 3390 2006 Sunrise Medical 12 06 930578 Rev B...