MN3000100022
Page 10
3
Rx+
Rx+
4
Rx-
Rx-
5
GND
GND
GND
2.3 Jumper Settings
This USB to RS-22/485 Serial Adapter equips independent TX and RX
termination resistors for each serial port. User can modify the jumper
settings (short the pins) to avoid impedance mismatched problem when
operate under Multi-drop transmission. User will need to open up the
metal covers, and set the jumper setting to enable or disable 120 ohms
termination resistors.
Factory default jumper setting is OPEN (disable 120 ohms termination
resistors across the two wires).