Sunpery C222 Operating Instructions Download Page 3

 

Operating instructions 

C222 (#924302) remote handset 

 

 

 

corresponding channel LED will enter a slow 
blink sequence 

6.

 

The motor will jog after 3 to 5 seconds to 
confirm limit has been saved 

7.

 

Repeat steps #5 and #6 for setting the 
LOWER LIMIT (closed position), with the 
exception that the CENTER and B buttons 
are used instead 

8.

 

Press and hold the STOP button, after 3 to 5 
seconds the motor will jog to confirm that it 
has exited CONFIG MODE 

9.

 

Test limits by using the OPEN and CLOSE 
buttons and seeing if the motor stops at the 
correct position on both ends 

Note: 

It does not matter in which order the limits are 
set (i.e. upper followed by lower, or lower 
followed by upper). Also, either limit can be 
readjusted at any time in the future without the 
need to reset the other limit. Simply adjust the 
intended limit and exit. 

To set intermediate stops

 

THIS APPLIES TO ENCODED MOTORS ONLY 

By default, the buttons A, CENTER, and B will 
move the motor to, respectively, 25%, 50%, and 
75% encoder positions. The following steps are 
used to customize these positions. 

1.

 

Make sure the correct channel is selected 
on the handset 

2.

 

Press and hold the A and B buttons 
simultaneously  –  corresponding channel 
LED will enter a slow blink sequence 

3.

 

The motor will jog after 3 to 5 seconds to 
confirm it has entered CONFIG MODE – 
once in CONFIG MODE, motor will move 
only  with  a maintained button press on 
either the OPEN or CLOSE button 

4.

 

Run the motor by holding the OPEN or 
CLOSE button, release when intended 
intermediate position is reached 

5.

 

To set current position as FIRST 
INTERMEDIATE, press and hold the A button 

6.

 

The motor will jog after 3 to 5 seconds to 
confirm position has been saved 

7.

 

Repeat steps #5 and #6 for setting the other 
intermediate positions, with the exception 
that the CENTER and B buttons  are used to 
set the SECOND INTERMEDIATE and THIRD 
INTERMEDIATE respectively 

8.

 

Press and hold the STOP button, after 3 to 5 
seconds the motor will jog to confirm that it 
has exited CONFIG MODE 

9.

 

Test  intermediate stops  by using the A, 
CENTER, and B buttons  and seeing if the 
motor stops at the correct positions 

Note: 

Similarly to setting limits, it does not matter in 
which order the intermediate stops  are set, or 
even if they are set at all (which will remain at 
default).  Each intermediate position  can  be 
readjusted at any time  without the need to 
reset the others. Simply adjust the intended 
intermediate stop and exit. 

To delete current channel from motor memory

 

1.

 

Make sure the correct channel is selected 
on the handset 

2.

 

Press and hold the STOP and OPEN buttons 
simultaneously  –  corresponding channel 
LED will enter a slow blink sequence 

3.

 

The motor will jog after 3 to 5 seconds to 
confirm current channel has been deleted 

4.

 

Test by making sure the motor no longer 
responds to any commands from the 
present channel 

Summary of Contents for C222

Page 1: ...rocess but is otherwise reliable More advanced features that are present on encoded motors are typically unavailable Sunpery produces both encoded and non encoded motors and they will all work with the C222 remote handset Due to the different features of these motors operating procedures can diverge and will be noted where applicable Standard operations Once a motor has been commissioned and calib...

Page 2: ... motors 1 Confirm current travel direction is wrong by using the OPEN and CLOSE buttons 2 Power off motor for 1 minute then power on again 3 Within 90 seconds of motor power on press and hold the A and B buttons simultaneously corresponding channel LED will enter a slow blink sequence 4 The motor will jog after 3 to 5 seconds to confirm it has entered CONFIG MODE 5 Once in CONFIG MODE while still ...

Page 3: ...in CONFIG MODE motor will move only with a maintained button press on either the OPEN or CLOSE button 4 Run the motor by holding the OPEN or CLOSE button release when intended intermediate position is reached 5 To set current position as FIRST INTERMEDIATE press and hold the A button 6 The motor will jog after 3 to 5 seconds to confirm position has been saved 7 Repeat steps 5 and 6 for setting the...

Page 4: ...correct channel is selected on the handset 2 Press and hold the STOP and CLOSE buttons simultaneously corresponding channel LED will enter a slow blink sequence 3 The motor will jog after 3 to 5 seconds to confirm all channels have been deleted 4 Test by making sure the motor no longer responds to any commands ...

Page 5: ...and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Company Sunpery Nanjing Co Ltd Name RF Remote Transmitter Model Number C222 9120 FCC ID VXC C222 ...

Reviews: