Operating instructions
C222 (#924302) remote handset
3
corresponding channel LED will enter a slow
blink sequence
6.
The motor will jog after 3 to 5 seconds to
confirm limit has been saved
7.
Repeat steps #5 and #6 for setting the
LOWER LIMIT (closed position), with the
exception that the CENTER and B buttons
are used instead
8.
Press and hold the STOP button, after 3 to 5
seconds the motor will jog to confirm that it
has exited CONFIG MODE
9.
Test limits by using the OPEN and CLOSE
buttons and seeing if the motor stops at the
correct position on both ends
Note:
It does not matter in which order the limits are
set (i.e. upper followed by lower, or lower
followed by upper). Also, either limit can be
readjusted at any time in the future without the
need to reset the other limit. Simply adjust the
intended limit and exit.
To set intermediate stops
THIS APPLIES TO ENCODED MOTORS ONLY
By default, the buttons A, CENTER, and B will
move the motor to, respectively, 25%, 50%, and
75% encoder positions. The following steps are
used to customize these positions.
1.
Make sure the correct channel is selected
on the handset
2.
Press and hold the A and B buttons
simultaneously – corresponding channel
LED will enter a slow blink sequence
3.
The motor will jog after 3 to 5 seconds to
confirm it has entered CONFIG MODE –
once in CONFIG MODE, motor will move
only with a maintained button press on
either the OPEN or CLOSE button
4.
Run the motor by holding the OPEN or
CLOSE button, release when intended
intermediate position is reached
5.
To set current position as FIRST
INTERMEDIATE, press and hold the A button
6.
The motor will jog after 3 to 5 seconds to
confirm position has been saved
7.
Repeat steps #5 and #6 for setting the other
intermediate positions, with the exception
that the CENTER and B buttons are used to
set the SECOND INTERMEDIATE and THIRD
INTERMEDIATE respectively
8.
Press and hold the STOP button, after 3 to 5
seconds the motor will jog to confirm that it
has exited CONFIG MODE
9.
Test intermediate stops by using the A,
CENTER, and B buttons and seeing if the
motor stops at the correct positions
Note:
Similarly to setting limits, it does not matter in
which order the intermediate stops are set, or
even if they are set at all (which will remain at
default). Each intermediate position can be
readjusted at any time without the need to
reset the others. Simply adjust the intended
intermediate stop and exit.
To delete current channel from motor memory
1.
Make sure the correct channel is selected
on the handset
2.
Press and hold the STOP and OPEN buttons
simultaneously – corresponding channel
LED will enter a slow blink sequence
3.
The motor will jog after 3 to 5 seconds to
confirm current channel has been deleted
4.
Test by making sure the motor no longer
responds to any commands from the
present channel