background image

 

6

When the unit if off: press of the Timer button and the Timer-On indicator will illuminate 

(indicating auto-start is initiated). Press Timer button again and the Timer-Off indicator 

will illuminate (indicating auto-stop is initiated). 

Press or hold the +/- buttons to change the set time in 0.5-hour increments, up to 10 

hours; then in 1-hour increments, up to 24 hours. 

The selected time will register after 5 seconds and the panel will revert back to 

displaying ambient humidity. 

When both auto-start and auto-stop times are set, both Timer On and Off indicator lights 

are illuminated, identifying both On and Off timers are now programmed. 

Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel 

any timer programs. 

Timer program is also cancelled when LED displays P2 error code. 

 
 

IDENTIFICATION OF PARTS 

 

FRONT 

1.  Control panel 
2.  Air intake grille 
3.  Air outlet grille 
4.  Air filter (behind the grille) 
5.  Water bucket 
6.  Handle (both sides) 

 

REAR 

1.  Continuous drain hose outlet 
2.  Caster 
3.  Power cord and plug 
4.  Band (for use when storing the unit) 
5.  Pump drain hose outlet 

 

 

 

ACCESSORIES 

 

 

Note: all pictures in this manual are for explanation purposes only. The actual product may differ slightly, but the 
operations and functions are the same. 

 

 

Summary of Contents for SD-52PE

Page 1: ...DEHUMIDIFIER with BUILT IN PUMP MODELS SD 52PE SD 72PE INSTRUCTION MANUAL Please read these instructions thoroughly and keep it in a safe place for future reference ...

Page 2: ...prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities A The municipality has established collection systems where electronic waste can be disposed of at free of charge to the user B The manufacturer will take back the old appliance for disposal at free of charge to the user C As old products contain valuable resources they may be sold to s...

Page 3: ...h damaged cord or connect unit to damaged electrical socket 4 Do not modify power cord length or share outlets with other appliances 5 Do not insert or remove plug with wet hands 6 Do not use in the following locations Next to or near a heat source radiator heater dryer etc Area where oil or water is likely to splash Under direct sunlight Near a bath shower or swimming pool In a greenhouse Near fl...

Page 4: ...ormation The manufacture s rating label is located on the back panel of the unit and contains electrical and other technical data specific to this unit Be sure the unit is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock Never remove the grounding prong Your unit must be used...

Page 5: ...urs of operation To reset after cleaning the filter press the Filter button to turn off indicator light FAN Controls the fan speed Press to select Turbo high or Normal fan speed Set the fan to Turbo for maximum moisture removal When the humidity has reduced or when quiet operation is preferred set the fan speed to Normal POWER Press to turn the dehumidifier on and off UP DOWN Set humidity level Pr...

Page 6: ...or additional 3 minutes then stop unit will resume when ambient humidity rises 5 above set humidity Auto Defrost When frost builds up on the evaporator coils the compressor will cycle off and the fan will continue to run until the frost disappears 3 Minute Delay After the unit has stopped or powered off there will be a 3 minute delay before it will resume operation again This is to protect the com...

Page 7: ...oth Timer On and Off indicator lights are illuminated identifying both On and Off timers are now programmed o Turning the unit ON or OFF at any time or adjusting the timer setting to 0 0 will cancel any timer programs o Timer program is also cancelled when LED displays P2 error code IDENTIFICATION OF PARTS FRONT 1 Control panel 2 Air intake grille 3 Air outlet grille 4 Air filter behind the grille...

Page 8: ... to help prevent moisture damage The dehumidifier must operate in an enclosed area to be most effective Close all doors windows and other outside openings to the room Casters Allow unit to move freely Do not force casters to move over carpet Do not move unit with water in the bucket as unit may tip over and spill water Before using the unit When running the unit for the first time operate the unit...

Page 9: ...ause the unit to malfunction o When the bucket is removed and you notice water in the unit you must dry up the water o If the pump drops when you remove the bucket please reinstall the pump properly before replacing bucket Fig 3 o When the unit is operating and bucket is removed the compressor and fan will stop unit will beep 8 times and display will show Eb o When the unit is off and bucket is re...

Page 10: ...er hose to the floor drain or suitable drainage facility Press the PUMP button to activate pump Pump will begin to operate when the water in the bucket reaches a pre determined level Note The pump may make some noise during initial operation 3 to 5 minutes This is normal Make sure the hose connection is secure so there will be no leaks Make sure the hose has no kinks or sharp bends Note If the Pum...

Page 11: ...lace bucket in the dishwasher After cleaning make sure outside of bucket is dried off before replacing to its seat Clean the Air Filter Filter should be cleaned once every two weeks based on normal operating conditions First remove the bucket and pull filter downwards to remove Fig 12 Wash the filter with clean water and allow to air dry completely Re install the filter and replace bucket Caution ...

Page 12: ...windows and doors are open Not enough time allowed to remove the moisture Humidity setting may be set too high Ambient temperature is too cold below 41 F Unit is noisy Unstable setting of unit or floor surface is not level Blocked filter Frost appears on coils This is normal The dehumidifier has Auto Defrost feature Water on floor Hose connection for continuous drainage or pump drainage is loose I...

Page 13: ...cement parts will be new or reconditioned Parts which are replaced become the property of Sunpentown The warranty applies for the use of the product in the USA only What is NOT COVERED Warranty does not include freight charges Incidental or consequential damage caused by possible defects with this product Damage to product caused by improper power supply voltage accident fire floods or acts of nat...

Reviews: