General safety 

 

eArc that fall under this application class may be used in system operation at more than 50V DC or 

240W, where general contact access is anticipated. eArc are qualified for safety under IEC 61730-2 and 

within this application class are considered to meet the requirements for Safety Class II. 

 

eArc are qualified for Application Class A(IEC 61730-1). 

 

Installing solar photovoltaic systems requires specialized skills and knowledge. Installation should only 

be performed by qualified personnel. 

 

Installers should assume all risks of injury that might occur during installation, including, but not limited 

to, the risk of electric shock. 

 

One single eArc may generate more than 30V DC when exposed to direct sunlight. Contact with a DC 

voltage of 30V or more is potentially hazardous. 

 

Do not disconnect during load connection. 

 

Photovoltaic solar eArc convert light energy to direct current electrical energy. They are designed for 

outdoor use. eArc can be ground mounted, mounted on rooftops, vehicles or boats. The proper design 

of support structures lies within the responsibility of the system designers and installers.   

 

Do not use mirrors or other magnifiers to concentrate sunlight onto eArc. 

 

When  installing  the  system,  abide  to  all  local,  regional  and  national  statutory  regulations.  Obtain  a 

building permit if necessary. 

 

eArc  electrical  characteristics  are  within 

±

10%  of  the  indicated  values of  Isc,  Voc  and  Pmax  under 

standard test conditions (Irradiance of 1000W/m

²

, AM 1.5 spectrum, a cell temperature of 25

 ). 

 

Only use equipment, connectors, wiring and support frames suitable for solar electrical systems. 

 

“Always  use  fall  protection  equipment  when  working  from  heights  of  6  feet 

183cm

or  above”.   

Follow Occupational Safety and Health Act (OSHA) or local governing safety regulations regarding fall 

protection. (UL only) 

 

 

Handling safety 

 

Do not lift eArc by grasping eArc’ junction box or electrical leads. 

 

Do not stand, step or walk on any side of eArc. 

 

Do not drop eArc or allow objects to fall on eArc. 

 

Do not place any heavy objects on eArc. 

 

Be cautious when placing eArc down onto a surface, particularly when placing it in a corner. 

 

Inappropriate transport and installation may break eArc and void the warranty. 

 

Do not attempt to disassemble eArc, and do not remove any attached nameplates or components from 

eArc. 

Summary of Contents for eArc SMA160M-4X09DW

Page 1: ...eArc PV System Installation Manual...

Page 2: ...his guide Features Benefits Notices General safety Handling safety Installation safety Fire safety Production Identification Mechanical Installation Grounding Electrical installation Disclaimer of lia...

Page 3: ...tion For any questions please contact SUNMAN s Customer Service Department or our local representatives for more detailed information Installers should follow all safety precautions described in this...

Page 4: ...w sunman energy com version 2019A page 2 18 TM Features Benefits Flexible layouts eArcTM PV system can be installed at any shape roofs which has integrated appearance with buildings Maximization insta...

Page 5: ...s required for eArcTM PV System PV arrays Copyright and Trademark Information Copyright 2019 by Sunman Zhenjiang Company Limited All rights reserved eArc and the SUNMAN logo are trademarks of Sunman Z...

Page 6: ...d mounted mounted on rooftops vehicles or boats The proper design of support structures lies within the responsibility of the system designers and installers Do not use mirrors or other magnifiers to...

Page 7: ...nections or unplug connectors while the circuit is under load Contact with electrically charged parts of the panels such as terminals can result in burns sparks and lethal shock whether or not the pan...

Page 8: ...ated current rated voltage open circuit voltage short circuit current all as measured under standard test conditions weight dimensions etc the maximum system voltage is 1000 volts Barcode each individ...

Page 9: ...ing eArc with a tilt angle of at least 10 degrees making it easier for dust to be washed off by rain Always keep the back sheet of the panel free from foreign objects plants and vegetation or structur...

Page 10: ...steel roof sheeting Any other roof sheeting requires consolation with Sunman or its local importer b Size of color steel roofing c Preparation of bonding material Prepare silicone nozzle by cutting a...

Page 11: ...n to clean cloth Wiping down the roof apply to the adhesion area Reapply until clean Leave to dry e Install chemical bonding material Apply the silicon with the nozzle perpendicular to the roof The le...

Page 12: ...manual are subject to change without notice www sunman energy com version 2019A page 10 18 TM f Layout of SMD Series Layout For SMD Series SMDxxxM 6X12DW SMDxxxM 6X12UW SMDxxxM 6X10DW SMDxxxM 6X10UW...

Page 13: ...o not install using quick bonding method when rain is present Do not install using quick bonding method when wind speeds greater than 10m s are present at the site within 24 hours Roof and ambient tem...

Page 14: ...be properly secured to their supports so that they can withstand the pressure of the load including the rise and pressure of the wind It is the responsibility of the installer to ensure that the moun...

Page 15: ...always grounded SUNMAN recommends always refer to local state and national code requirements for PV module grounding SUNMAN highly recommends negative grounding if it s allowed by local authorities W...

Page 16: ...ding is achieved by bonding all conductors on the module frame and metal mounting structures continuously with a suitable grounding conductor Third party grounding solutions are acceptable These solut...

Page 17: ...ort circuit current The recommended cable is PV wire temperature rating is 90 with a cross section of at least 2 5mm Please refer to local regulations to determine the system wires size type and tempe...

Page 18: ...1 9 52 1662mm X 1019mm X 5 6mm 5 5kg 20A 20 SMD290M 6X10DW 290 32 6 8 90 39 9 9 43 1662mm X 1019mm X 5 6mm 5 5kg SMD285M 6X10DW 285 32 4 8 80 39 7 9 34 1662mm X 1019mm X 5 6mm 5 5kg SMD280M 6X10DW 280...

Page 19: ...m X 995mm X 35mm 7 6kg 20A 20 SMA290M 6X10DW 290 32 6 8 90 39 9 9 43 1638mm X 995mm X 35mm 7 6kg SMA285M 6X10DW 285 32 4 8 80 39 7 9 34 1638mm X 995mm X 35mm 7 6kg SMA280M 6X10DW 280 32 2 8 70 39 5 9...

Page 20: ...X 665mm X 35mm 6 4kg SMA225M 4X12UW 225 25 5 8 83 31 3 9 36 1983mm X 665mm X 35mm 6 4kg SMA220M 4X12UW 220 25 2 8 74 31 1 9 27 1983mm X 665mm X 35mm 6 4kg SMA215M 4X12UW 215 24 9 8 64 30 9 9 18 1983mm...

Page 21: ......

Page 22: ......

Reviews: