Summary of Contents for Oasis I12

Page 1: ...es Unit 1 20 22 Foundry Road Seven Hills NSW 2147 T 02 9838 0000 Queensland Unit 1 8 Reichert Drive Molendinar QLD 4214 T 07 5679 6821 sales sunloverheating com au sunloverheating com au SWIMMING POOL...

Page 2: ...perature setting 15 4 6 Clock setting 15 4 6 A System time setting 15 4 6 B Setting and cancelling the Timer ON OFF function 16 4 7 Silent setting 17 4 7 A One click silent function 17 4 7 B Setting a...

Page 3: ...time and frequency as stated in this manual The appliance shall be installed in accordance with national wiring regulations Use genuine standard spare parts only Do not use means to accelerate the de...

Page 4: ...ker can lead to electrical shock or fire The heat pump located inside the unit is equipped with an over load protection system It does not allow for the unit to start for at least 3 minutes from a pre...

Page 5: ...ooling Capacity kW 3 7 4 5 5 1 6 1 Cooling Power Input kW 1 5 1 9 2 0 2 2 Running Current A 1 1 7 2 1 5 9 2 2 2 12 8 2 6 16 8 Power Supply V Ph Hz 10 AMP Plug 10 AMP Plug 240 1 50 240 1 50 Compressor...

Page 6: ...ANUAL INVERTER SERIES I9 I12 I17 I19 SWIMMING POOL HEAT PUMP UNIT sales sunloverheating com au sunloverheating com au 6 2 SPECIFICATION 2 2 The dimensions for Swimming Pool Heat Pump Unit Oasis I9 Oas...

Page 7: ...stration are necessary spare parts for the water system that provided by users or the installer Attention Please follow these steps when using for the first time 1 Open valve and charge water 2 Make s...

Page 8: ...ischarge air will be re circulated DO NOT place the unit to shrubs which can block air inlet These locations deny the unit of a continuous source of fresh air which reduces it efficiency and may preve...

Page 9: ...piping By using a 50 NB to 40NB you can plumb 40NB Give serious consideration to adding a quick coupler fitting at the unit inlet and outlet to allow easy draining of unit for winterizing and to prov...

Page 10: ...nd permits turning off power at the unit while the unit is being serviced 3 6 Initial start up of the Unit NOTE In order for the unit to heat the pool or spa the filter pump must be running to circula...

Page 11: ...heating mode under the automatic mode the mute key operation is effective and used to enter and exit the mute mode with one click Mode key It is used to switch the unit mode temperature setting and pa...

Page 12: ...ction is started it keeps bright for a long time When it is in mute state it will flash Or else it is off Timing It will display after the user sets the timing and multiple timing intervals can be set...

Page 13: ...Notes Startup shutdown operation can only be conducted in the main interface When it displays with half screen off or full screen off click any key for returning to ON OFF main interface When the unit...

Page 14: ...escriptions 1 Mode switch operation can only be conducted in the main interface 2 When the unit is under the defrosting state the defrosting symbol is on with the display interface as follows Notes Af...

Page 15: ...return to the main interface without any changes saved If there is no operation for 5 s or short press the current mode will be saved and return to the main interface 4 6 Clock setting 4 6 A System ti...

Page 16: ...I17 I19 SWIMMING POOL HEAT PUMP UNIT sales sunloverheating com au sunloverheating com au 16 4 USAGE AND OPERATION 4 6 B Setting and cancelling the Timer ON OFF function Select ON1 OFF1 ON2 or OFF2 tim...

Page 17: ...the main interface 2 Under the Timer ON OFF setting interface If the timing symbol and entire time digits flash at the same time click to return to the main interface 3 Timer ON1 OFF1 ON2 OFF2 settin...

Page 18: ...sunloverheating com au 18 4 USAGE AND OPERATION 4 7 B Setting and cancelling the silent function Notes 1 When the silent icon is lighten the timing mute has been set but it s not under silent status...

Page 19: ...ng operation is available and the screen will be lighten after other operations conducted 2 Under the OFF interface locking operation is available and the operation method is the same as locking scree...

Page 20: ...WIMMING POOL HEAT PUMP UNIT sales sunloverheating com au sunloverheating com au 20 4 USAGE AND OPERATION 4 10 Parameter list and breakdown table 4 10 A Electronic control fault table Can be judged acc...

Page 21: ...ALLATION INSTRUCTION MANUAL INVERTER SERIES I9 I12 I17 I19 SWIMMING POOL HEAT PUMP UNIT sales sunloverheating com au sunloverheating com au 21 4 USAGE AND OPERATION Frequency conversion board fault ta...

Page 22: ...AND OPERATION 4 10 B Parameter table Meaning Default Remark Heating inlet target temp 28 C Adjustable Cooling inlet target temp 28 C Adjustable Auto inlet target temp 27 C Adjustable The wire control...

Page 23: ...ION MANUAL INVERTER SERIES I9 I12 I17 I19 SWIMMING POOL HEAT PUMP UNIT sales sunloverheating com au sunloverheating com au 23 4 USAGE AND OPERATION 4 12 Main board Oasis I7 I19 Controller interface di...

Page 24: ...220 230VAC 8 P1 AC L Live wire input 220 230VAC 9 P2 AC N Neutral wire input 220 230VAC 10 CN99 PL Pressure sensor 11 CN29 OVT Water flow switch input 12 CN30 HP High pressure switch input 13 CN31 LP...

Page 25: ...ts safety checks are necessary to ensure that the risk of ignition is minimised For repair to the refrigerating system the following precautions shall be complied with prior to conducting work on the...

Page 26: ...ey shall be fit for the purpose and to the correct specification At all times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical d...

Page 27: ...t the correct rating Replace components only with parts specified by the manufacturer Other parts may result in the ignition of refrigerant in the atmosphere from a leak Cabling Check that cabling wil...

Page 28: ...rvicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylin...

Page 29: ...scales before recovery takes place g Start the recovery machine and operate in accordance with manufacturer s instructions h Do not overfill cylinders No more than 80 volume liquid charge i Do not exc...

Page 30: ...nge the evaporator temp Sensor High pressure protect E01 The exhaust pressure is high high pressure switch action Check high pressure switch and cooling return circuit Low pressure protect E02 The suc...

Page 31: ...or the use of harmful substances in electric and electronic devices 7 The unit CANNOT be installed near the flammable gas Once there is any leakage of the gas fire can be occur 8 Make sure that there...

Page 32: ...2 I17 I19 SWIMMING POOL HEAT PUMP UNIT sales sunloverheating com au sunloverheating com au 32 6 APPENDIX 6 2 Cable specification 1 Single phase unit 2 Three phase unit When the unit will be installed...

Page 33: ...TION INSTRUCTION MANUAL INVERTER SERIES I9 I12 I17 I19 SWIMMING POOL HEAT PUMP UNIT sales sunloverheating com au sunloverheating com au 33 6 APPENDIX 6 3 Comparison table of refrigerant saturation tem...

Page 34: ...TION MANUAL INVERTER SERIES I9 I12 I17 I19 SWIMMING POOL HEAT PUMP UNIT sales sunloverheating com au sunloverheating com au 34 6 APPENDIX 6 4 Explosive view of the I 9 unit Electrical control structur...

Page 35: ...INSTALLATION INSTRUCTION MANUAL INVERTER SERIES I9 I12 I17 I19 SWIMMING POOL HEAT PUMP UNIT sales sunloverheating com au sunloverheating com au 35 6 APPENDIX...

Page 36: ...TION MANUAL INVERTER SERIES I9 I12 I17 I19 SWIMMING POOL HEAT PUMP UNIT sales sunloverheating com au sunloverheating com au 36 6 APPENDIX 6 5 Explosive view of the I 12 unit Electrical control structu...

Page 37: ...INSTALLATION INSTRUCTION MANUAL INVERTER SERIES I9 I12 I17 I19 SWIMMING POOL HEAT PUMP UNIT sales sunloverheating com au sunloverheating com au 37 6 APPENDIX...

Page 38: ...TION MANUAL INVERTER SERIES I9 I12 I17 I19 SWIMMING POOL HEAT PUMP UNIT sales sunloverheating com au sunloverheating com au 38 6 APPENDIX 6 6 Explosive view of the I 17 unit Electrical control structu...

Page 39: ...INSTALLATION INSTRUCTION MANUAL INVERTER SERIES I9 I12 I17 I19 SWIMMING POOL HEAT PUMP UNIT sales sunloverheating com au sunloverheating com au 39 6 APPENDIX...

Page 40: ...TION MANUAL INVERTER SERIES I9 I12 I17 I19 SWIMMING POOL HEAT PUMP UNIT sales sunloverheating com au sunloverheating com au 40 6 APPENDIX 6 7 Explosive view of the I 19 unit Electrical control structu...

Page 41: ...INSTALLATION INSTRUCTION MANUAL INVERTER SERIES I9 I12 I17 I19 SWIMMING POOL HEAT PUMP UNIT sales sunloverheating com au sunloverheating com au 41 6 APPENDIX...

Page 42: ...INSTALLATION INSTRUCTION MANUAL INVERTER SERIES I9 I12 I17 I19 SWIMMING POOL HEAT PUMP UNIT sales sunloverheating com au sunloverheating com au 42 NOTES...

Page 43: ...INSTALLATION INSTRUCTION MANUAL INVERTER SERIES I9 I12 I17 I19 SWIMMING POOL HEAT PUMP UNIT sales sunloverheating com au sunloverheating com au 43 NOTES...

Page 44: ...xfield VIC 3180 Australia T 03 9887 2131 New South Wales Unit 1 20 22 Foundry Road Seven Hills NSW 2147 Australia T 02 9838 0000 Queensland Unit 4 8 Reichert Drive Molendinar QLD 4214 Australia T 07 5...

Reviews: