13
SAC600
Use soft cloth to clean surface, and remove all moisture before using.
Drainage:
This portable air conditioner collects moisture from the air. If the humidity around
the machine is low, the water in the unit will be completely vaporized by the condenser.
There will be less water in the tank, and there will be no need to drain the water
tank. But, if the humidity around the unit is heavy, the unit will capture
more water, and the water will not be able to be vaporized by the condense r.
When the water tank is full, the machine will shut off, and an alarm will sound.
The LCD display will show “E4”. Then the machine will stop after the fan keeps working for
3 minutes. In order to drain the water in the water tank, please do the following:
1.
Put the water drain tray under the machine.
2.
Remove the drain cap underneath the back of the unit.
3.
Drain all the water in the water tank.
4. Re-fasten the drain cap.
Before contacting repair services, please check the following:
Problem
Cause
Solution
The unit does
not work
Power supply faulty
1. Not plugged in
2. Bad plug or socket
3. Fuse blown, or faulty wiring
1. Plug in correctly
2. Change the plug or socket
3. Send unit to service center to
replace fuse (fuse:3.15A 250V)
The unit
stops running
automatically
Timer is set, or room temperature is
lower than set temperature
Shut off timer or wait
to run automatically
No cool air in
cooling mode
1. Room temperature is lower
than set temperature
2. There is frost on the evaporator
1. It is a normal occurrence
2. The unit is defrosting and will
run properly when process is
fi nished
No cool air in
dehumidifying
mode
Frost on the evaporator
The unit is defrosting and
will run properly when
process is fi nished
Error code E2
Room temperature sensor failure
Change the room
temperature sensor
Error code E3
Indoor coil sensor failure
Change the indoor coil sensor
Error code E4
Water tank is full
Empty water in water tank
Maintenance & Trouble Shooting