Table of Contents 

Specification …………………………………………………………………………………….. 

Introduction   …………………………………………………………………………………... 

1.  Safety information …………………………………………………………………….. 

2.  Product diagram and package list………………………………………………….. 

3.  Assembly instruction and tools required…………………………………………. 

4. Operation 

……………………………………………………………………………….. 

4.1 Leak check…………………………………………………………………………. 

4.2 Ignition and setting control……………………………………………………… 

4.3 Shut down……………………………………………………………………......... 

5. Storage 

………………………………………………………………………………….. 

6. Maintenance 

……………………………………………………………………………. 

7. Replacement 

parts 

list………………………………………………………………… 

8. Troubleshooting.……………………………………………………………………….  

9. Service 

………………………………………………………………………………….. 

10. Warranty terms…………………………………………………………………………. 

4-5 

6-7 

8-10 

9-10 

10 

10 

10 

11 

11 

12 

12 

 

 

IMPORTANT 

 

Read this manual carefully before assembling, using or servicing this patio heater. Keep this manual 

for future reference. 

For technical assistance on assembly or replacement parts, you can call us 

toll-free at 1-866-578-6569 from 8 a.m. EST to 8 p.m. PST 

or email to [email protected] 

or visit www.sunjoyonline.com to place your order or fax your parts replacement order form together 

with your purchase receipt to 1-740-283-3549 for assistance.

 

 

Installation and service must be performed by a 

qualified installer, service agency or gas supplier.

 

 

Installer: Leave this manual with consumer   
Consumer: Keep this manual for future reference.

 
 

 
 
 

SPECIFICATIONS 

 
 

Rated Heat Input 

33,000 BTU/Hr per burner, 64,000 BTU/Hr dual burners 

Fuel 

Liquid Propane Gas 

Gas Supply 

20 lb. LP-Gas cylinder 

Manifold Pressure 

11 inches W.C 

Orifice Size (diameter) 

2.00 mm 

Safety Features 

Flame failure device, Tilt switch   

Gas Supply Pressure 

Max. 250 PSI, Min. 5 PSI   

Summary of Contents for L-PH004PCA

Page 1: ...r loss of life DANGER If you smell gas Shut off gas to the appliance Extinguish any open flame If odor continues keep away from the appliance and immediately call your gas supplier or fire department WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing...

Page 2: ...ment parts you can call us toll free at 1 866 578 6569 from 8 a m EST to 8 p m PST or email to customer care sunjoygroup com or visit www sunjoyonline com to place your order or fax your parts replacement order form together with your purchase receipt to 1 740 283 3549 for assistance Installation and service must be performed by a qualified installer service agency or gas supplier Installer Leave ...

Page 3: ...n the cylinder valve outlet whenever the cylinder is not in use Only install the type of dust cap on the cylinder valve that is provided with the cylinder valve Other types of capes or plugs may result in leakage of propane Use only 20lb LP Gas tank with size of 18 1in 46cm Height 12 5in 32cm Width Certain items or material when stored under the heater or nearby will be subjected to radiant heat a...

Page 4: ... compartment burners and circulating air passageways of the heater be kept clean Tank supply system must be arranged for vapor withdrawal The tank used must include a collar to protect the cylinder valve The pressure regulator and hose assembly provided with the appliance must be used Replace only with the pressure regulator and hose assembly supplied by manufacturer The heater when installed must...

Page 5: ...ecorative Top st op Base anel left ding Descriptio Bolt Nut Screw Screw Screw Screw Screw QTY 1 1 2 1 1 1 1 1 n QTY 18 12 6 6 2 16 8 Made in Chin Item J K L M N P Q ITEM LH LI LJ LK LL na Desc Shan Shan B Shroud P D Shan Reg Hardw PICTURE cription nk rear nk left Base Panel right Door k right gulator are Pack E Des W C S W W QTY 1 1 1 1 1 1 1 1 scription Washer Cap Nut Screw Wrench Washer 5 12 QTY...

Page 6: ... uctions ached Diagr ks left Shan ect position b Panel left eft and Shro rear and S nd 8 washer N re Pack on rams k rear and by using 6 fl Shroud P oud Panel r Shank right rs LL as sho Fi Made in Chin e Philip Scr Shank ange St In 6 Panel right by own St At sc Fig 3 g 5 na ew Driver an tep2 Instal stall Table T flange bolts tep4 Instal ttach Door to crews LD nd two Adjus l Table Top Top Base on LA...

Page 7: ... nuts slide fixing control kno e same sid heavy assi Fig 11 Fi Fig Made in Chin s LA St Ca us Pu Ta m sing 16 on the St At sc end of obs of de and istance St Ha of wr ig 7 9 na tep6 Instal arefully insta sing 6 screw ut down Tab able Top tep8 Attach ttach Post D crew LJ tep10 Conn and screw c f connector h rench l Table Top all Table Top ws LC and 6 le Top Deco h Post Deco Decorative pi nect Regul...

Page 8: ...test f ixing soap a bs are at OF he cylinder c necter of the ortions of ho ear and or heck at leas st by pulling n post and c as cylinder in ble gas hose nder and ga on of soapy so or not bubble nection is se eak Turn off gain Made in Chin s which are ogether rol knob rig ane cylinde of the U S for leaks and water 1 FF position cabinet and e regulator in ose prior to abrasion p st annually p g out...

Page 9: ...n there is a le k again persists ple ing control ter cap and t with anode cap ry of the ign e with a new battery when of time ol knobs are line and ga der is on of soapy so ole Inspect control hou e connection ons See Fig ection is sec ak Turn off t again line and lef er is on Pus ht control kn décor brush or not bulbs nection is se eak Turn of ease call 1 l put 1 AA 1 5 e outward a iter has run w...

Page 10: ...LOW position than seen in HIGH position Always check flame prior to each use Perform flame check prior to each use If only low flame is seen refer to Burner flame is low in the Troubleshooting Section 4 3 Shut down 4 3 1Turn control knobs clockwise to OFF to shut down the patio heater 4 3 2 Open the door of Cylinder Cabinet and turn off gas supply at gas supply cylinder 4 3 3 Disconnect by unscrew...

Page 11: ...ually check the burner flame with pictorial representations 7 REPLACEMENT PARTS LIST Item Description Item Description U Control Knob X Electrode V Igniter Y Thermocouple W Tilt Switch Z Regulator If you want to replace the parts listed please consult 1 866 578 6569 for assistance and advice 8 Troubleshooting PROBLEM WHAT TO DO Burner won t light Does the Gas Cylinder contain gas Check the Gas sup...

Page 12: ...s found defective in workmanship and or materials during the warranty period and can be repaired or replaced at the discretion of the manufacturer at no cost to the original purchaser 10 3 This warranty will be void and accordingly no claim of any nature will be enforceable if the product has not been assembled installed or operated according to the instructions subjected to abuse improperly treat...