Sunjoy 810367912 Assembly Instruction Manual Download Page 12

12 of 15 

 

 

 

 

 

 

 

 

 

OPERATION: 

LEAK TEST 

!!!WARNING!!! 

 

Do not use an open flame to check for leaks.   

 

 

 

Do not smoke during testing.   

 

 

 

Do not test indoors.   

 

 

 

A leak check must be performed whenever the gas cylinder is replaced.

 

1. Make sure the control knob is in the “OFF” position.     
2. Make sure the gas cylinder is correctly and securely connected to the pressure regulator, without over 
tightening.   
3.  Turn  on  the  gas  cylinder  valve.  Apply  50%  soap  and  50%  water  solution  to  the  gas  hose  and 
connections between the control knob and gas cylinder.     
4. If something is leaking, you will see bubbles form. In case of leaks, turn off the gas supply, undo the 
leaking connection, re-connect it and try again. If the leak persists, consult Customer Service Center for 
assistance (

1(866) 578-6569

).   

5. If the connection does not leak, continue to the next step. 
 

LIGHTING THE BURNERS 

1. Make sure control valve is OFF.     
2. Turn on gas tank valve.     
3. Press in and turn control valve knob counterclockwise to LOW to light. 
See the figure to the right.   
4. If burner is lit, continue pressing in the control valve knob for a minute to 
heat the thermocouple.     
5. When control valve knob is released, the burner should be lit. If not, turn 
control  valve  knob  clockwise  to  OFF.  Wait  for  5  minutes  then  start  with 
step 3 above.     
6.  Press  in  and  turn  control  valve  knob  to  desired  heat  output,  LOW  ~ 
HIGH. 

Fig 8

 

OFF

HIGH

MAX

BAS

ARRET

LOW

Fig.7

Summary of Contents for 810367912

Page 1: ...d the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable vapors and liquids in the vic...

Page 2: ...14 Limited warranty 14 GENERAL INFORMATION IMPORTANT Please take time to read these instructions thoroughly and follow each step carefully for safe and easy operation Keep this manual to consumer for...

Page 3: ...is gas appliance When using decorative Lava Rocks use only Lava rocks INCLUDED The appliance shall be used only outdoors in a well ventilated space and shall not be used in a building garage or any ot...

Page 4: ...ccordance with the specifications for LP gas cylinders of the U S Department of Transportation DOT The cylinder supplies system must be arranged for vapor withdrawal and the cylinder must include a co...

Page 5: ...5 of 15 EXPANDED VIEW...

Page 6: ...D2 Table panel 2 P21109A01118 1 M Thermocouple P99001E04000 1 E Side panel P21110A01118 1 N Control Valve P99001F04000 1 F Door P20913A01118 1 O Control Knob P99001G07001 1 F1 Door handle P90007A0111...

Page 7: ...e the parts listed please contact Customer Service Center 1 866 578 6569 Step 1 Insert the round column of the table panel 1 D1 into the hole of the side panel E then attach table panel 1 D1 to side p...

Page 8: ...le of table panel 1 D1 Then attach gas jar frame G to table panel 1 D1 by bolt CC and washer BB as Fig 2 showed Use the same way to attach gas jar frame G to table panel 2 D2 Step 3 Put the Table Top...

Page 9: ...ide panel E to the table top B by bolt AA and flat washer BB Note When installing the fire bowl please make sure the bowl C with control panel should face the door F Step 5 Attach the door handle F1 t...

Page 10: ...10 of 15 Step 6 Put the Lid A on the Table Top B Step 7 The lava rock H should be put in the bottom of the Fire Bowl C and come up just as high as the fire ring...

Page 11: ...ry into the bottom of battery box as shown in Fig 2 Then screw the battery box as shown in Fig 3 Fig 1 Fig 2 Fig 3 Note If the battery of the pulse electronic igniter runs out of power please replace...

Page 12: ...ks turn off the gas supply undo the leaking connection re connect it and try again If the leak persists consult Customer Service Center for assistance 1 866 578 6569 5 If the connection does not leak...

Page 13: ...building garage or any other closed area The fireplace may be stored indoors only if the cylinder is disconnected and removed Keep the fireplace area clear and free from combustible materials gasoline...

Page 14: ...aired or replaced at the discretion of the manufacturer at no cost to the original purchaser This warranty will be void if the product has not been assembled installed or operated according to the ins...

Page 15: ...run the burner on high for 30 minutes 4 Once lit do not go within 10 feet of the fire pit for the first 30 minutes on the first use 5 After the first 30 minutes resume normal operation Do not stand ov...