34
No.
Name
Description
13
DC input plug-in terminal
for
connecting
Tracker
control cabinet
Reseved
Connect the cable through the corresponding interfaces on the bottom
of the inverter during power cable and communication cable
connection;
Tie the communication cables (e.g. RS485 and the dry contact) to
prevent interference with the power cables.
*On site, wire conduit can be used as a substitute for the gland. Take replacing
AC gland as an example, operation steps are as follows:
Step 1
Remove the sealing plate (M6
Allen driver).
Step 2
Unscrew the gland (wrench *2, opening: 86mm)
Diameter:75.8mm/2.98in
5.1.2 Dimensions of Terminal
Before selecting the cable side terminals, please notice the dimensions of the
AC & DC terminals specified in the figure to make sure the selected terminals
are proper.