2 LCD Operation
User Manual
8
If a DRED is connected to the eShow and the
DRED activates a DRM command, the DRM
state will be shown on the main screen, as
shown in the figure.
Tab. 2-3
Demand Response Modes (DRMs)
Mode
Explanation
DRM0
The inverter is in the state of standby.
DRM5
The export power to the grid is 0%.
DRM6
The export power to the grid is no more than 50% of the rated power.
DRM7
The export power to the grid is no more than 75% of the rated power.
DRM8
The export power to the grid is 100%, but subject to the constraints from
other active DRMs.
Viewing Current Fault
If inverter is in “Fault” state, touch
to
view “Current fault” information. To know
the meaning of the fault code, please
refer to “
3.1 Troubleshooting
”.
2.4
Contrast Adjustment
Step 1
Press/touch
on the main screen to enter the contrast adjustment screen.
Step 2
Touch
to increase the setting value and
touch
to decrease the value.
Step 3
Press
to confirm the contrast setting.
Contrast adjustment range: 0…100%
Recommended value: 50% or 60%.