SFK-275HP
Lithium Iron Phosphate
08
Parameter Value
Notes
Minimum Discharge
Temp.
34° Fahrenheit
Battery will go into Safe Mode at this temperature.
Maximum Charge
Temp.
120° Fahrenheit
//
Minimum Charge
Temp.
34° Fahrenheit
//
Short Circuit Protec-
tion
155 amps
The BMS will turn the battery off if more than 155
amps are drawn from the battery.
Usable Battery Capac-
ity
275 AH
This is regulated by the BMS to ensure battery
integrity.
Total Cell Capacity
285-290 ah
This is the actual cell capacity of the individual cells.
Charging & Discharging:
MAINTENANCE
Sun Fun Kits Lithium Iron Phosphate batteries require minimal maintenance and do not need to have any
liquid added to them such as water (in the case of flooded lead acid) in order to keep charge. The only
maintenance required is to ensure that the state of charge of the battery is in a reasonable state depend-
ing on how it is being used. Please see the chart below:
State of Charge Recommended Use Notes
80-100%
Normal Use
For normal everyday use, keep your battery in this
range if you are using it at least once a month.
50%
Long term storage
Keep your battery in this state when you will not be
using it (for more than a month).
25-35%
Transport
For use in transport / maintenance, when your
battery is shipped to you, or if you need to return it,
it should be in this SOC.