![Sunforce BLUE SKY ENERGY IPN Remote Installation And Operation Manual Download Page 3](http://html1.mh-extra.com/html/sunforce/blue-sky-energy-ipn-remote/blue-sky-energy-ipn-remote_installation-and-operation-manual_1396228003.webp)
3
2
Operation
The IPN Remote provides a digital display of battery voltage and output charge current. The display
alternates between voltage and output current when charging. Current is displayed when the “AMPS”
indicator is ON and can be the total of all controllers on the IPN network (factory default), or the current
of a single controller on the IPN network. An automatic night time dimming feature reduces display
brightness when PV (Panel) charge is OFF.
Charge Status Indicator
AMPS Indicator
DIP Switch
Charge Off:
Off
Bulk (<70 % Full):
Continuously On
Absorption (70 % - 95 % Full):
Blinking 1 SEC ON / 1 SEC OFF
Float (Fully Charged):
Blinking 0.2 SEC ON / 1 SEC OFF
Equalize:
Rapid Blinking
0.2 SEC ON / 0.2 SEC OFF
IPN
Dimensional Drawing
BA
T+
BA
T-
PV
-
PV
+
IPN
Wiring Diagram
Network and
power cable
A2
A1
A0
IPN TOT
OFF
ON
Direct wiring charge controller
and IPN Remote
Wiring charge controller
and IPN Remote
through BT Connect
SB3024
IPN Remote
BT Connect