3

2

Operation

The IPN Remote provides a digital display of battery voltage and output charge current. The display 
alternates between voltage and output current when charging. Current is displayed when the “AMPS” 
indicator is ON and can be the total of all controllers on the IPN network (factory default), or the current 
of a single controller on the IPN network. An automatic night time dimming feature reduces display 
brightness when PV (Panel) charge is OFF.

Charge Status Indicator

AMPS Indicator

DIP Switch

Charge Off: 

 Off

Bulk (<70 % Full): 

 Continuously On

Absorption (70 % - 95 % Full):

 

Blinking 1 SEC ON / 1 SEC OFF

Float (Fully Charged):

 

Blinking 0.2 SEC ON / 1 SEC OFF

Equalize: 

Rapid Blinking

                          0.2 SEC ON / 0.2 SEC OFF

IPN

 

Dimensional Drawing

BA

T+

BA

T-

PV

-

PV

+

IPN

 

Wiring Diagram

Network and 

power cable

A2

A1

A0

IPN TOT

OFF

ON

Direct wiring charge controller 

and IPN Remote

Wiring charge controller 

and IPN Remote 

through BT Connect

SB3024

IPN Remote

BT Connect