Thank You for Purchasing 200Watt Power Inverter 

For the most beneficial, efficient operation, and long term use from your new inverter, please read carefully the 
information and explanation of features contained in this manual. You are also advised to keep this manual in a safe 
place for ready reference. 

 
Introducing the 200W Inverter 

These inverters lead the field in power inverters and set the pace in development and design. They have been 
meticulously assembled to provide reliable service, converting low voltage, direct current (DC) to 110 volt alternating 
household current (AC).  
 

CAUTION: WORKING WITH BATTERIES 

To reduce the risk of battery explosion, follow all instructions of the battery manufacturer and all manufacturer 
instructions of additional components.  

 
RISK OF EXPLOSIVE GAS – Working in the vicinity of a lead acid battery is dangerous.  Lead acid batteries 
contain hydrogen-oxygen gases that can cause explosion and sulfuric acid that can cause severe burns.  
Always work in a well ventilated area.   
DO NOT SMOKE, OR ALLOW A SPARK OR A FLAME IN THE VICINITY OF A BATTERY! 
Remove personal metal items such as rings, necklaces, watches, and bracelets when working with a battery.  
Be extra cautious to reduce risk of dropping a metal tool on to the battery.  The battery may spark or short 
circuit. 
NEVER CHARGE A FROZEN BATTERY  
 
If battery acid contacts skin or clothing, wash immediately with soap and water.  If acid enters the eye, 
IMMEDIATELY FLOOD EYE WITH RUNNING COLD WATER for at least 10 minutes.  GET MEDICAL 
ATTENTION IMMEDIATELY. 
 
Failure to comply with above warnings may lead to explosion, and or severe injury. 

 

Working with Inverters 

  For most effective use place the power inverter on a flat surface. 

  Keep the inverter dry.   

  Do not expose the inverter to moisture, including rain, snow, spray mist, or excessive 

humidity.  

  To reduce risk of fire hazard, do not cover or obstruct the ventilation openings. Do not install 

the inverter in a non ventilated space. Overheating may result. 

  Do not place the inverter near heating vents, radiators or other sources of heat. 

  Do not place the inverter in direct sunlight, ideal temperature is 50°F – 80°F (10°C – 26°C). 

  Use appropriates cables and attachments.  To avoid a risk of fire and electric shock, make 

sure that existing wiring is in good electrical condition; and that wire size is not undersized.  
Do not use damaged or low grade wires.  To ensure adherence to proper electrical wiring 
regulations all wiring must be done by a certified technician or electrician.   

  Do not use inverter if it has been dropped or damaged. 

  Keep the inverter away from flammable materials. 

   Do not attempt to repair or disassemble the inverter.  Risk of shock and fire.  Any alterations 

to the inverter will render the warranty void. 

  Disconnect the inverter from all connections before performing any maintenance on any of the 

equipment, such as changing a fuse on the inverter. 

  This is not a toy-keep away from children. 

 

Summary of Contents for 200Watt POWER INVERTER

Page 1: ...200 Watt POWER INVERTER Onduleur de puissance 200W User s Manual Notice D utilisation...

Page 2: ...FROZEN BATTERY If battery acid contacts skin or clothing wash immediately with soap and water If acid enters the eye IMMEDIATELY FLOOD EYE WITH RUNNING COLD WATER for at least 10 minutes GET MEDICAL A...

Page 3: ...is safety feature prevents damaging the unit while testing appliances and equipment within the watt range Important Make sure you connect your 200W inverter to a 12 volt power supply only Do not attem...

Page 4: ...ppliance or equipment being operated If the fuse does blow 1 Disconnect the appliance or equipment immediately 2 Find the source of the problem and repair it 3 Install the new fuse The fuse can be fou...

Page 5: ...e temperature of the battery charger for about 10 minutes If the battery charger becomes abnormally warm disconnect it from the inverter immediately Use only 25 amp spade type fuses If you are powerin...

Page 6: ...Poor contacts are causing voltage drop Unplug and reattach connections Check condition of 12 volt plug and socket clean or replace as necessary Turn inverter ON OFF then ON again Appliance not functio...

Page 7: ...vous travaillez avec une batterie Soyez extr mement prudent pour r duite les risques d chapper un outil m tallique sur la batterie La batterie pourrait g n rer des tincelles ou tre court circuit e NE...

Page 8: ...pour d terminer si l appareil que vous utilisez est compatible avec un onduleur onde sinuso dale modifi e Pour calculer la plupart des charges de pointes Charge de pointe 2 x WATTAGE W En g n ral la c...

Page 9: ...c ble de l antenne du bloc d alimentation de 12 volts 4 Tentez d enrouler le cordon d alimentation du t l viseur et le c ble d alimentation branch entre le bloc d alimentation de 12 volts et l ondule...

Page 10: ...sultat que ces voltm tres affichent une mesure de 20 30 volts trop basse lors de la mesure de la tension de sortie de l onduleur Pour mesurer la tension de sortie de l onduleur avec pr cision utilise...

Page 11: ...Dimensions 6 25 x 4 25 x 2 5 15 9 x 10 8 x 6 4 cm Poids approx 1 8 lb 0 8 kg...

Page 12: ...entilation ad quate Voyant DEL rouge allum Onduleur possiblement d fectueux Contactez l assistance t l phonique Utilisez un filtre sur le cordon d alimentation du t l viseur Interf rence lectrique cau...

Page 13: ...ez contacter Sunforce Products pour des directives additionnelles au 1 888 278 6235 ou par courriel info sunforceproducts com Une preuve d achat incluant la date de l achat facture et une explication...

Reviews: