1. Speaker Level Outputs

This is the connection to the Sunfire 

HRSIW8 in-wall subwoofer. Use high-

quality Class- speaker wiring. 

The red post is the positive output, and 

connects to the positive (red) post of 

the HRSIW8 subwoofer. The black post 

is the negative, and connects to the 

negative (black) post of the HRSIW8 

subwoofer. The five-way, gold-plated 

posts can accept bare wire, pins, spade 

terminals, and dual or single banana 

connectors.

The amplifier is designed to power 

only the Sunfire HRSIW8 in-wall 

subwoofer. No other subwoofer 

or speaker should be connected, 

or this may lead to serious damage to 

your equipment.

14. Voltage Select Switch

This switch allows the amplifier to be 

set to the local AC mains voltage, either 

115 VAC or 0 VAC.

Always unplug the power cord and 

all other connections, before mov-

ing this switch. Undo the two small 

screws and remove the protec-

tive plate covering the switch. Set the 

switch to the local AC mains voltage. 

Replace the protective cover.

15. Line Fuse

The subwoofer is supplied with a con-

servative

 

slow-blow type fuse to protect 

the electronics.

Always unplug the power cord 

before inspecting or changing 

the fuse. Never use a fuse with a 

larger current rating than shown 

on the markings next to the fuseholder. 

Use a small flat screwdriver to pry out 

the fuseholder and replace the fuse.

16. IEC Linecord socket

The amplifier comes with a detachable 

linecord which connects here. 

US (120 VAC) MODEL: Connect the 

linecord to the amplifier before connect

-

ing the other end to a 10 Volt, 60 Hz 

AC outlet. The outlet must have a cir-

cuit rating of 8 amps or more (a typical 

home circuit is rated at 15 amps).

Never plug the US (120 VAC) 

Model amplifier directly into 220-

40 Volts AC as this will cause 

catastrophic circuit failure.

European (230 VAC) MODEL: Connect 

the linecord to the amplifier before con

-

necting the other end to a 0 Volt,  50 

Hz AC outlet. The outlet must have a 

circuit rating of 4 amps or more.

HRSIW8AMP

15

14

16

HRSIW8AMP

1

Summary of Contents for HRSIW8

Page 1: ...User s Manual High Resolution Series In Wall Subwoofer Amplifier HRSIW8 ...

Page 2: ...ed upon or against them paying particu lar attention to cords at plugs convenience receptacles and the point where they exit the apparatus 13 Non use Periods The power cord of the apparatus should be unplugged from the outlet when unused for a long period of time 14 Object and Liquid Entry Care should be taken so that objects do not fall into and liquids are not spilled into the inside of the appa...

Page 3: ...anada 21 This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential instal lation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor dance with the instructions may...

Page 4: ...rranty and it may come in useful for insurance purposes Please take a moment to fill out and mail the Sunfire Customer Response card Also read the serial number located on the control panel and record it here Serial Number Purchased from Date Features Amplifier designed exclusively for the Sunfire HRSIW8 in wall subwoofer 500 Watt all discrete Class D switch ing amplifier for maximum robustness DS...

Page 5: ...housemates when playing movies late into the night 12V trigger for advanced home system control Remote Infrared sensor jack for the custom home installer Audio sense timeout is adjustable from 5 30 minutes Care To maintain the amplifier s finish first unplug the power cord and then use a soft dry cloth to clean the surfaces Move the cloth with the grain of the front panel s finish Be careful not t...

Page 6: ...i fier is on and red when it is in standby mode 4 DSP Display This vacuum fluorescent display VFD shows the status of the amplifier s controls Multiple menus allow full con trol of the amplifier s parameters and performance 5 DSP Control This control allows selection and ad justment of the amplifier s parameters It can be turned clockwise counter clockwise and pressed in to navigate through the DS...

Page 7: ...t it to either of these inputs leaving the other one unused If your preamplifier or receiver does not have a sub LFE output use Y adapt ers at the preamplifier outputs In this way you can send the preamplifier s output signals to your main amplifier and to the subwoofer amplifier at the same time 9 Trigger Inputs This input can be used to automatically turn on the amplifier To do this con nect a 1...

Page 8: ...late covering the switch Set the switch to the local AC mains voltage Replace the protective cover 15 Line Fuse The subwoofer is supplied with a con servative slow blow type fuse to protect the electronics Always unplug the power cord before inspecting or changing the fuse Never use a fuse with a larger current rating than shown on the markings next to the fuseholder Use a small flat screwdriver t...

Page 9: ...SP menus select param eters and adjust them up or down through the available options D Exit Press this to exit from the DSP menus All settings are left as they are E Night On Off This turns on or off the Night mode suitable for late night listening F EQ Presets These five buttons allow quick selection of EQ presets Impact Movie Music Dynamic and Flat These EQ presets have been carefully designed f...

Page 10: ...tilation around the top and sides of the amplifier Allow adequate ventilation if you are rack mounting the amplifier AC Power Considerations Ensure that the amplifier is plugged into an outlet capable of supplying the correct voltage specified for your model Unplug your amplifier s power cord from the electrical outlet if it will be left unused for a long period of time Route the power supply cord...

Page 11: ...er s Manual 11 System Configuration HRSIW8AMP HRSIW8 In Wall Subwoofer HRSIW8 Amplifier Connect balanced or unbalanced inputs to the SUB LFE line level output of your home theater preamplifier or receiver ...

Page 12: ...tion is as follows Turn DSP Control left or press the LEFT button on the remote control Turn DSP Control Right or press the RIGHT button on the remote control Press the DSP Control in or press the ENTER button on the remote control DSP Controls Normal SUB or LFE Mode Night Mode On Not Muted Muted EQ Mode Volume Level Output Signal Level Enable External Trigger Enable Lock Setting Auto Off Setting ...

Page 13: ...ange below the cutoff frequency The current crossover slope is also displayed If LFE is chosen in the SUB LFE menu then the crossover frequency and slope are set flat and are not adjustable the menus are hidden Decrease Increase Crossover Slope Slope Select the crossover slope from 12 18 24 30 or 36 dB octave The current crossover frequency is also displayed If LFE is chosen in the SUB LFE menu th...

Page 14: ...hysical placement and distance of the subwoofer in relation to the main speakers may result in unwant ed cancellation of some of the bass and can be compensated for by adjusting the phase setting The phase setting can be adjusted while listening for maximum or best bass performance or by using a real time analyzer and measuring the actual response of the system as a whole Increase Night Mode This ...

Page 15: ...r Frequency can be adjusted and so these menus are available In LFE mode the Crossover Slope and Crossover Frequency cannot be ad justed and so these menus are hidden The crossover adjustment is then left to the Home Theater preamplifier Select SUB or LFE Auto Off The amplifier will automatically turn on from standby if a trigger voltage is applied to the 12VDC trigger input on the rear panel This...

Page 16: ...ngs of the DSP can be saved as a snapshot in one of three memory locations This will allow you to quickly save your favorite settings When the amplifier DSP settings are to your liking go to this menu and save in memory 1 2 or 3 The memory recall menu will allow you to easily recall these settings at any time Memory 1 2 or 3 Up Down Memory 1 2 or 3 Up Down ...

Page 17: ...vels Greater than 106 dB peak SPL includes room gain Measurement is at 1 meter anechoic Total Harmonic Distortion amplifier Less than 0 5 at 500W into 4Ω Input Sensitivity full output 23 mV rms at 38 Hz with volume control set to maximum Input Impedance 49 kΩ for Line Level input 20 kΩ for XLR input XLR Input Pin 1 Ground Pin 2 Positive Pin 3 Negative 12 VDC Trigger Input Input voltage range 2 2 1...

Page 18: ...User s Manual 18 ...

Page 19: ...red in connection with repair or replacement Except as may be expressly provided and authorized in writing by Sunfire Sunfire shall not be subject to any other obligations or liabilities whatsoever with respect to equip ment manufactured by Sunfire or services rendered by Sunfire THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESSED AND IMPLIED WARRANTIES EXCEPT WARRANTIES OF T...

Page 20: ...Manual 9901231 Rev A High Resolution Series In Wall Subwoofer Amplifier HRSIW8 Sunfire 1969 Kellogg Ave Carlsbad CA 92008 www sunfire com HRSIW8AMP ...

Reviews: