background image

SUNERGY USA WORKS LLC

2

1. APPLICATIONS

SUNERGY Solar PV modules are a highly reliable, virtually maintenance-free direct current (DC)

power source, designed to operate most efficiently in sunlight. SUNERGY series modules are ideal

to power remote homes, recreational vehicles, water pumps, telecommunications systems and

many other applications either with or without the use of storage batteries. Class A, Modules rated

for use in this application class may be used in systems operating at greater than 50V DC or 240W,

where general contact access is anticipated. Modules qualified for safety through this part of IEC

61730-1 and IEC 61730-2 and within this application class are considered to meet the

requirements for safety class II.

Notes:

 The recommended maximum series/parallel module configurations are as follow:

72 6 " mono series: 16/1       60 6 " mono series: 20/1

54 6 " mono series: 21/1       36 6 " mono series: 32/1

72 6 " poly series: 17/1        60 6 " mono poly: 20/1

54 6 " poly series: 23/1        36 6 " mono poly: 34/1

2. PERMIT

Before installing your system, contact local authorities to determine the necessary permit,

installation and inspection requirements.

3.  CLIMATE CONDITION

Install the SUNERGY Solar crystalline series modules in the following conditions:

   Ambient temperature:    -20°C to + 40°C

   Operating temperature:   -40°C to +85°C

   Storage temperature:     -40°C to +40°C

    Humidity:                               below  85RH%

  Wind pressure:           below 50.12Ib / ft

2

(2400Pa)

   Corrosion resistance:     Except for corrosive salt area and sulfurous area.

4.  WARNING AND NOTES FOR SAFE INSTALLATION WORK

This system shall be installed only by engineers who have completed the training course.

Each solar panel has a junction box, can provide cable according to customer’s requirement.

Summary of Contents for SUN160-36P

Page 1: ... s Street Ste 330 Raleign NC 27605 WAKE USA 1 1 POWER MODULE SUNERGY USA WORKS LLC Solar Photovoltaic modules consist of a series of electrically interconnected crystalline silicon solar cells Which are permanently encapsulated between a tempered glass superstrate and substrate The entire laminate is secured within an anodized aluminum frame for structural strength ease of installation and to prot...

Page 2: ...commended maximum series parallel module configurations are as follow 72 6 mono series 16 1 60 6 mono series 20 1 54 6 mono series 21 1 36 6 mono series 32 1 72 6 poly series 17 1 60 6 mono poly 20 1 54 6 poly series 23 1 36 6 mono poly 34 1 2 PERMIT Before installing your system contact local authorities to determine the necessary permit installation and inspection requirements 3 CLIMATE CONDITIO...

Page 3: ... W m 25 C cell temperature and solar spectral irradiance per ASTME 892 or irradiation of AM 1 5 spectrum Under normal conditions a photovoltaic panel may experience conditions that produce more current and or voltage than reported at Standard Test Conditions Accordingly the values of Isc and Voc marked on should be multiplied by a factor of 1 25 when determining component voltage ratings conductor...

Page 4: ... together with spring washers and flat washers in eight places symmetrical on the SUNERGY module The applied torque is about 8 Newton meters The module can t be installed using clamps It is not permitted to modify the module frame under any circumstances Recommended distance between 2 solar modules is 5mm considering linear thermal expansion of the module frames Clearance between the module frame ...

Page 5: ...each module 11 2 The module frame must be attached to a supporting structure using M8 stainless steel hardware together with spring washers and flat washers in eight places symmetrical on the module 11 3 Clearance between the module frame and mounting surface may be required to prevent the junction box from touching the surface and to circulate cooling air around the back of the module 11 4 Connec...

Page 6: ...n broken do not be cleaned and immediately inform the installer or maintainer 13 3 Do not use cleaning components of a strong type of chemical or abrasive detergent and disinfectant operations To prevent serious pollution will reduce the output power We recommend using water to clean modules If the animals that produce the dirt a mild soapy water and neutral disinfectant will be recommended If nec...

Page 7: ...330 5 335 5 340 5 345 5 350 5 355 5 Maximum system voltage V 1000 1000 1000 1000 1000 1000 Maximum Over Current Protection Rating A 15 15 15 15 15 15 Module type SUN360 72 M SUN365 72 M SUN370 72 M SUN275 60 M SUN280 60 M SUN285 60 M Voc V Tolerance 47 9 5 48 1 5 48 3 5 38 0 5 38 2 5 38 7 5 Vmp V 38 9 39 1 39 3 31 9 31 1 32 2 Isc Adc Tolerance 9 75 5 9 82 5 9 85 5 9 21 5 9 35 5 9 48 5 Imp Adc 9 25...

Page 8: ... M SUN275 54 M SUN165 36 M Voc V Tolerance 35 7 5 36 2 5 36 6 5 36 9 5 37 3 5 23 1 5 Vmp V 28 8 29 0 29 1 29 3 29 4 19 1 Isc Adc Tolerance 9 35 5 9 45 5 9 6 5 9 7 5 9 81 5 9 17 5 Imp Adc 8 85 8 96 9 1 9 22 9 35 8 62 Pmp W Tolerance 255 5 260 5 265 5 270 5 275 5 165 5 Maximum system voltage V 1000 1000 1000 1000 1000 1000 Maximum Over Current Protection Rating A 15 15 15 15 15 15 Module type SUN170...

Page 9: ...on Rating A 15 15 15 15 15 15 Module type SUN270 60P SUN265 60P SUN250 54P SUN245 54P SUN240 54P SUN165 36P Voc V Tolerance 37 20 5 37 00 5 34 80 5 34 30 5 33 50 5 23 00 5 Vmp V 31 20 31 00 28 50 28 30 28 10 18 90 Isc Adc Tolerance 9 06 5 8 94 5 9 19 5 9 05 5 8 95 5 9 16 5 Imp Adc 8 65 8 54 8 77 8 66 8 54 8 74 Pmp W Tolerance 270 5 265 5 250 5 245 5 240 5 165 5 Maximum system voltage V 1000 1000 1...

Page 10: ...SUNERGY USA WORKS LLC 10 Temperature cofefficient Temp Cofe Of Isc 0 048 C Temp Cofe Of Voc 0 30 C Temp Cofe Of Pmax 0 40 C ...

Reviews: