![SunEarth MTG-LSR-52-19 Installation Instructions Download Page 2](http://html.mh-extra.com/html/sunearth/mtg-lsr-52-19/mtg-lsr-52-19_installation-instructions_1395739002.webp)
Note:
In situations where the rack is to be mounted other than parallel to the roof line, cross bracing may be necessary.
If you have any questions or feedback, please feel free to email us at sales&[email protected].
Complete Installation
Tilt the collector up, position the Back Legs to the desired
angle, insert the bolts, and tighten nuts. Attach Rear Legs
to Support Strut, lower collector, and insert Rear Legs into
Rear Feet. Insert bolt and tighten.
Step 4
Step 5
Position collector face up on the Support Strut, insert clips
into Support Strut, and secure collector to Support Strut
with clips. SunEarth recommends placing the Support Strut
approximately 10 ~ 20% in from each end of the collector for
maximum strength.
Assemble Rear Legs[ , and ] and position the legs to the
desired angle using the pre-drilled holes (See Angle and Spacing
Table below). Mark the position of Rear Feet and securely fasten
to mounting surface. Detach the Rear Leg from the Support
Strut and Rear Feet. Lower the Support Strut to the mounting
surface.
www.sunearthinc.com
2 4
6
Step 3
20°
26°
29°
38°
40°
45°
50°
55°
60°
MTG-LSR-52-19
51.75"
-
-
-
-
-
-
-
-
MTG-LSR-52-25.5
-
54.5"
42.5"
-
-
-
-
-
-
MTG-LSR-52-40
-
-
-
62.25" 59.25"
51"
39.25"
-
-
24°
26°
31°
38°
40°
45°
50°
55°
60°
MTG-LSR-42-19
42.5"
34.75"
-
-
-
-
-
-
-
MTG-LSR-42-25.5
-
-
45.5"
30.5"
-
-
-
-
-
MTG-LSR-42-40
-
-
-
-
-
54.75"
49"
43.5"
37.75"
22°
25°
29°
34°
42°
45°
50°
55°
60°
MTG-LSR-52-19
46.25" 39.25"
-
-
-
-
-
-
-
MTG-LSR-52-25.5
-
-
49"
35.5"
-
-
-
-
-
MTG-LSR-52-40
-
-
-
-
57.5"
54.5"
48"
41"
32.5"
27°
32°
36°
40°
45°
49°
50°
55°
60°
MTG-LSR-42-19
37.25" 27.75"
-
-
-
-
-
-
-
MTG-LSR-42-25.5
-
-
40.75"
36"
28"
-
-
-
-
MTG-LSR-42-40
-
-
-
-
-
50.75"
50"
46.25" 42.25"
1st Hole
2nd Hole
Angle and Foot Spacing Table
Models may include more than two rear leg
positioning holes. Utilization of holes other than
the two outer most holes is
PROHIBITED
, since
doing so may impact the structural capacity of
the rack.